Definition

Serial (RS-232) Controls and Operation

This parameters selects the various open loop and closed loop operating modes as well as the feedback method.

Bit

Definition

 

 

See pages

2:0

Motor Control Mode

0 = A & B separate speed open loop

page 42

 

 

(default)

page 101

 

 

 

 

 

 

1

= A & B mixed speed open loop

page 89

 

 

 

 

 

 

2

= A speed open loop, B position

 

 

 

3

= A & B position

 

 

 

4

= A & B separate speed closed loop

 

 

 

5

= A & B mixed speed closed loop

 

 

 

6

= A speed close loop, B position

 

 

 

 

 

 

6:3

Reserved

 

 

 

 

 

 

 

6

Ch1 Feedback type

0 = Analog

page 101

 

 

1

= Encoder

page 89

 

 

 

 

7

Ch2 Feedback type

0 = Analog

 

 

 

1

= Encoder

 

 

 

 

 

 

Amps Limit

Address:

^02

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter configures the controller’s Amps limit. Note that this limits the amps flow- ing out of the power supply. Current flowing through the motors may be higher.

Bit

Definition

 

 

See pages

 

 

 

 

3:0

Coarse Amps

0 = 15A

page 44

 

 

1

= 22.5A

 

 

 

2

= 30A

 

 

 

3

= 37.5A

 

 

 

4

= 45A

 

 

 

5

= 52.5A (default)

 

 

 

6

= 60A

 

 

 

 

 

7:4

Fine Amps

Mutliply this number by 0.5 and substract

 

 

 

result from the Coarse Amps value

 

 

 

 

 

 

Acceleration

Address:

^03

Access:

Read/Write

Effective:

After Reset or ^FF

150

AX3500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 150
Image 150
RoboteQ AX3500 Amps Limit, Acceleration, Serial RS-232 Controls and Operation, Definition, See pages, Address, Access