Input Control Mode

Accessing & Changing Configuration Parameter in Flash

TABLE 25. Configuration parameters in Flash

Location

Description

 

Active after

 

 

 

^1A

Joystick Max 1 MS

Instant

 

 

 

 

^1B

Joystick Max 1

LS

Instant

 

 

 

 

^1C

Joystick Max 2

MS

Instant

 

 

 

 

^1D

Joystick Max 2

LS

Instant

 

 

 

^F0

Amps Calibration Parameter 1

Reset

 

 

 

^F1

Amps Calibration Parameter 2

Reset

 

 

 

 

These parameters are stored in the controller’s Flash memory and are not intended to be changed at runtime.

Important Notice

The above parameters are stored in the MCU’s configuration flash. Their storage is perma- nent even after the controller is powered off. However, because of the finite number of times flash memories can be reprogrammed (approx. 1000 times), these parameters are not meant to be changed regularly, or on-the-fly.

All parameters in Flash (except for the Amps calibration) are reset to their default values every time new firmware is loaded into the controller.

Input Control Mode

Address:

^00

Access:

Read/Write

Effective:

After Reset

This parameter selects the method the controller uses for accepting commands

Value

Mode

See pages

 

 

 

0

R/C Radio mode (default)

page 113

 

 

 

1

RS232, no watchdog

page 113

 

 

 

2

RS232, with watchdog

 

 

 

 

3

Analog mode

page 127

 

 

 

Motor Control Mode

Address:

^01

Access:

Read/Write

Effective:

After Reset or ^FF

AX3500 Motor Controller User’s Manual

149

Page 149
Image 149
RoboteQ AX3500 Input Control Mode, Motor Control Mode, Important Notice, Location, Description, Active after, Address