RoboteQ AX3500 Selecting the R/C Input Mode, Connector I/O Pin Assignment R/C Mode, Pin1, Number

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 114
Image 114
R/C Operation

R/C Operation

Selecting the R/C Input Mode

The R/C Input Mode is the factory default setting.

If the controller has been previously set to a different Input Mode, it will be necessary to reset it to the R/C mode using one of the following methods:

Restoring the factory defaults by pressing and holding the Program and Set but- tons while powering on the controller until the LED display flashes

Setting the “I” parameter to the value “0” using one of several methods described in the chapters “Configuring the Controller using the Switches” on page 175, “Using the Roborun Configuration Utility” on page 181, and “Accessing & Changing Configuration Parameter in Flash” on page 147.

Connector I/O Pin Assignment (R/C Mode)

9

15

Pin1

8

FIGURE 72. Pin locations on the controller’s 15-pin connector

When used in R/C mode, the pins on the controller’s DB15 connector are mapped as described in the table below.

TABLE 19. Connector pin-out in R/C mode

Pin

Input or

 

 

Number

Output

Signal

Description

1 and 9

Output

Output C

2A Accessory Output C

 

 

 

 

2

Output

RS232 data

RS232 Data Logging Output

 

 

 

 

3

Input

Ch 1

R/C radio Channel 1 pulses

 

 

 

 

4

Input

Ch 2

R/C radio Channel 2 pulses

 

 

 

 

5 and 13

Power Out

Ground

Controller ground (-)

 

 

 

 

6

GND In

Ground

Optocoupler GND Input

 

 

 

Unused in RevB Hardware

 

 

 

 

7

+5V In

+5V

Optocoupler +5V Input

 

 

 

Unused in RevB Hardware

 

 

 

 