Loading, Changing Controller Parameters

Loading, Changing Controller Parameters

Loading, Changing Controller Parameters

The first set of tabs allows you to view and change the controller’s parameters. These tabs are grouped according to the general type of parameters (Controls, Power Setting, and R/C Settings).

When starting Roborun, this screen is filled with the default values. If the controller is con- nected to your PC, Roborun will automatically detect it and ask you if you wish to read its settings.

The controller’s setting in the PC at can be read any other time by pressing the “Load from Controller” button. After changing a parameter, you must save it to the controller manually by pressing the “Save to Controller” button.

Control Settings

1

2

3

4

5

6

FIGURE 103. Control modes setting screen

The screen shown in Figure 103 is used to view and change the controller’s main control modes. Below is the list of the parameters accessible from this screen:

1- Controller Input:

This pull down menu allows the user to select the RS232, R/C or Analog mode of opera- tion. If the RS232 mode is selected, a check box will appear, allowing you to enable or dis- able the RS232 Watchdog. For more information on these modes, see

R/C Operation” on page 113

Serial (RS-232) Controls and Operation” on page 135

RS-232 Watchdog” on page 142

Analog Control and Operation” on page 127

2- Motor Control Mode