Restart

Press & hold Prog

Program mode entered after 10 seconds

Press Prog to select next parameter

Press Set to select next value for parameter

Press Prog to store change and select next parameter

Reset controller to exit

Press and hold the Prog button for 10 seconds while resetting or powering on the controller

After 10 seconds, the controller will enter the program- ming mode and flash alternatively the current parame- ter (I= Input Mode) and its value (0= R/C mode).

Press the Prog button to move to the next parameter (C= Motor Control Mode) and its value (0= Separate)

Press the Set button to change the parameter’s value (1= Combined)

Press the Prog button record the change and move to the next parameter (A= Amps limit) and it’s value (2= 75A)

Press the Reset button or power off/on the control to restart the controller using the new parameters.

Connecting the controller to your PC using Roborun

Connecting the controller to your PC is not necessary for basic R/C operation. However, it is a very simple procedure that is useful for the following purposes:

to Read and Set the programmable parameters with a user-friendly graphical inter- face

to obtain the controller’s software revision and date

to send precise commands to the motors

to read and plot real-time current consumption value

Save captured parameters onto disk for later analysis

to update the controller’s software