RoboteQ AX3500 Input Switches Function, Accessing & Changing Configuration Parameter in Flash

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 151
Image 151
Input Switches Function

Accessing & Changing Configuration Parameter in Flash

This parameter configures the rate at which the controller internally changes the command value from the one it was to the one just received.

Bit

Definition

See pages

 

 

 

7:0

0 = very slow

See “Programmable Acceleration”

 

1

= slow

on page 47 for complete list of

 

acceptable values

 

(2) = medium-slow (default)

 

 

 

3

= medium

 

 

4

= fast

 

 

5

= fastest

 

 

 

 

 

Input Switches Function

Address:

^04

Access:

Read/Write

Effective:

After Reset or ^FF

This parameter enables and configures the effect of the controller’s Digital Inputs and other settings.

Bit

Definition

 

 

See pages

 

 

 

 

1:0

Enable and

(00) = Input Disabled (default)

page 51

 

Configure

01

= Input as Emergency Stop

page 52

 

Invert/Estop

 

10

= Disabled

 

 

 

 

 

 

11 = Input as Invert Command

 

 

 

 

 

2

Output C when

(0) = No Action (default)

page 51

 

Motor On

1 = Output C On when either motor is On

 

 

 

 

 

 

 

 

3

Encoder Safety

(0) = No Action (default)

page 81

 

 

1 = Disables Controller if Encoder detects

 

 

 

no movement while power is applied to

 

 

 

the motors

 

 

 

 

 

5:4

Input E

Unavailable

 

 

 

 

 

7:6

Input F

(00) = No action (default)

page 52

 

 

01

= Cut FET power when Input E is Low

page 53

 

 

10

= Activate output C

 

 

 

11 = Cut FET when Input E is High

 

 

 

 

 

 

AX3500 Motor Controller User’s Manual