Connecting to the Batteries and Motors

Connecting to the Batteries and Motors

Connecting to the Batteries and Motors

Connection to the batteries and motors is shown in the figure below and is done by con- necting wires to the Fast-on tabs on the controller.

Motor2

Optional

 

Power switch

 

+

Diode

Fuse

 

On

-

 

 

 

 

Off

 

+

 

 

-

Optional

Motor1

Emergency

 

Disconnect

VMot

M1-

M1+

PwrCtrl GND GND

GND

M2-

M2+

VMot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

12V to 24V

 

 

 

Controller

 

 

 

 

 

 

Motor Battery

Notes:

-The Battery Power connection are doubled in order to provide the maximum current to the controller. If only one motor is used, only one set of motor power cables needs to be connected.

-Typically, 1, 2 or 3 x 12V batteries are connected in series to reach 12, 24 or 36V respectively.

-The Power Control wire MUST be used to turn On and Off the controller.

FIGURE 3. AX3500 Electrical Power Wiring Diagram

1- Connect each motor to one of the two M+ and M- tabs pairs. Make sure to respect the polarity, otherwise the motor(s) may spin in the opposite direction than expected

2- Connect two of the three Ground tabs to the minus (-) terminal of the battery that will be used to power the motors. Connect the two VMot tabs the two VMot terminals to the plus

(+)terminal of the battery. The motor battery may be of 12 to 40 Volts. There is no need to insert a separate switch on Power cables, although one is suggested for Emergency dis- connect. See “Controller Power” on page 30 for a detailed discussion and more wiring options.

Avoid extending the length of wires from the battery to the controller as the added induc- tance may cause damage to the controller when operating at high currents. Try extending the motor wires instead since the added inductance on the motor side of the controller is not harmful.

The two VMot tabs are connected to each other inside the controller. The same is true for the tabs. You should wire each pair together as shown in the diagram above.

3- The Power control tab MUST be connected to Ground to turn the Controller Off. For turning the controller On, even though the Power Control may be left floating, whenever possible pull it to an unfused12V or higher voltage to keep the controller logic solidly On. You may use a separate battery to keep the controller alive as the main Motor battery dis- charges. Refer to the chapter “Connecting Power and Motors to the Controller” on page 29 for more information about batteries and other connection options.