RoboteQ AX3500 user manual Regeneration Current Limiting, Important Warning, General Operation

Models: AX3500

1 208
Download 208 pages 62.24 Kb
Page 46
Image 46
Motor Current = Battery Current / PWM Ratio

General Operation

Vbat

On

Motor

Off

FIGURE 19. Current flow during operation

On

Off

 

I mot

 

Avg

 

I bat

 

Avg

FIGURE 20. Instant and average current waveforms

The relation between Battery Current and Motor current is given in the formula below:

Motor Current = Battery Current / PWM Ratio

Example: If the controller reports 10A of battery current while at 10% PWM, the current in the motor is 10 / 0.1 = 100A.

Important Warning

Do not connect a motor that is rated at a higher current than the controller. While the battery current will never exceed the preset Amps limit, that limit may be reached at a PWM cycle lower than 100% resulting in a higher and potentially unsafe level through the motor and the controller.

Regeneration Current Limiting

The AX3500’s current sensor is capable of measuring current in the reverse flow (regener- ation). Using this capability, the controller will automatically relax the braking effect of the power output stage to keep the regeneration current within safe values. Because of the controller’s high current handling capabilities, this protection mechanism activates only when abrupt deceleration are applied to high-inertia, ultra-low impedance motors.

46

AX3500 Motor Controller User’s Manual

Version 1.9b. June 1, 2007

Page 46
Image 46
RoboteQ Regeneration Current Limiting, Important Warning, General Operation, AX3500 Motor Controller User’s Manual