SAFETY INFORMATION
We suggest that our gas hearth products be installed and serviced by professionals who are certified in the U.S. by the National Fireplace Institute® (NFI) as Gas Specialists.
www.nficertified.org
PRODUCT SPECIFICATIONS
MINIMUM HEARTH DIMENSIONS
MANUAL CONTROL
| Model | A | B |
| C | |
| VWF18 | 21" |
| 131/2" | 24" | |
| VWF24 | 27" |
| 131/2" | 30" | |
| VWF30 | 33" |
| 131/2" | 36" | |
| VWF36 | 39" |
| 131/2" | 42" | |
|
|
| ||||
| Model | A |
| B |
| C |
| VWF18 | 25" | 131/2" |
| 28" | |
| VWF24 | 31" | 131/2" |
| 34" | |
| VWF30 | 37" | 131/2" |
| 40" | |
| VWF36 | 43" | 131/2" |
| 46" |
*NOTE: Use the above chart for SRO and WP Manual Control Logs.
|
|
|
WARNING | Never connect unit to private | |
|
| |
|
| |
|
| gas is commonly known as |
|
| wellhead gas. |
|
|
|
Figure 1 - Minimum Hearth Dimensions
The manifold pressure for propane is 10" WC. The manifold pressure for natural is 4"WC.
The minimum inlet gas supply pressure is 4" WC for natural and 10" WC for LP.
The maximum inlet gas supply pressure for this log set is 10" WC for natural and 13" WC for LP.
Nominal Rates (BTU/Hr) |
|
|
|
|
|
|
VWF18N/P 60,000 | VWF24N | 70,000 | VWF30N | 80,000 | VWF36N | 80,000 |
| VWF24P | 60,000 | VWF30P | 60,000 | VWF36P | 60,000 |
Note: Actual performance, flame height, BTU/Hr will vary with specific installation, gas pressure, shutoff valve position (fully open), valve type, and firebox draft conditions.
4 | 27D8520 |