CONNECTING THE GAS

CONNECTING THE GAS

NOTICE: A qualified gas appliance installer must connect the heater to the gas supply. Consult all local codes.

CAUTION

Use new black iron or steel pipe. Internally tinned copper or copper tubing can be used per National Fuel Code, section 2.6.3, providing gas meets hydrogen sulfide limits, and where permitted by local codes. Gas piping system must be sized to provide minimum inlet pressure (Listed on Data Plate) at the maximum flow rate (BTU/Hr). Undue pressure loss will occur if the pipe is too small.

A manual shutoff valve must be installed upstream of the appliance. Union tee and plugged 1/8" NPT pressure tapping point should be installed upstream of the appliance. See Figure 4.

To Heater

Pipe Coupling

 

 

 

 

 

Valve

 

Pipe

Locations that the Pressure

 

 

 

 

 

 

 

 

Tapping Point May Be Installed

 

Stainless

 

 

 

Flexible Tube

 

 

 

Manual Shutoff

 

Gas Supply

 

 

Inlet

 

Valve

 

 

 

 

Figure 4 - Gas Connection

IMPORTANT: Hold heater valve firmly with a wrench to prevent movement when connecting to inlet pipe.

CAUTION

CHECK GAS TYPE: The gas supply must be the same as stated on the heater’s rating plate. If the gas supply is different, DO NOT INSTALL THE HEATER. Contact your dealer for the correct model.

Always use an external regulator for all propane/LPG heaters and high pressure one to two-pound systems only, to

reduce the supply tank pressure to a maximum of 13" w.c. This is in addition to the internal regulator in the heater valve.

45D0080

11

Image 11
Contents Do not try to light any appliance MODELS C2801VF, C2802VF C2803VF, and C2804VFNatural Gas or Propane/LPG Milli-VoltControl WHAT TO DO IF YOU SMELL GASCONTENTS OWNER IMPORTANT SAFETY INFORMATIONINSTALLER Continued from page IMPORTANT SAFETY INFORMATIONInstruction Thermostat Plates Sensor Hi/Lo Knob PRODUCT FEATURESOn/Off Switch Data andOptional Optional Remote Receiver Off/Pilot/On KnobMAKE SURE YOU HAVE RECEIVED ALL PARTS WHAT YOU WILL NEED FOR INSTALLATIONGETTING STARTED IGNITION CONTROLS PRODUCT SPECIFICATIONSNATURAL GAS PROPANE / LPGCODES GENERAL INSTALLATION INFORMATIONDo not install the heater … •In high traffic areas •In windy or drafty areasBTU/Hr = L1 GENERAL INSTALLATION INFORMATIONFront View Corner InstallationWall Installation CLEARANCES / HEIGHT REQUIRMENTSFigure 4 - Gas Connection CONNECTING THE GASexplosion Connecting directly to an unregulatedCONNECTING REMOTE RECEIVER propane/L.P.G. tank can cause anMillivolt ELECTRICAL WIRING MILLI-VOLTFigure 7 - Wiring Diagram CONNECTING OPTIONAL WALL SWITCH OR THERMOSTATScrews ELECTRICAL WIRING MILLI-VOLTFigure 8 - Removing Face Plate from Stove Plastic Clip OPERATION OF THERMOSTAT SENSORELECTRICAL WIRING MILLI-VOLT Figure 10 - Clipping Thermo Bulb intoa few hours to vent the odor LOG PLACEMENTDO NOT sprinkle volcanic rocks on the logs or around the pilot. This may cause sootingCHECKING PILOT FLAME FLAME APPEARANCECHECKING BURNER FLAME OPERATING INSTRUCTIONSWHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MILLI-VOLTCONTROL LIGHTING INSTRUCTIONSTO TURN OFF GAS TO HEATER MATCH LIGHTING INSTRUCTIONS OPERATING INSTRUCTIONS AND CLEANING AND SERVICINGCLEANING AND SERVICING Description REPLACEMENT PARTS LISTLOGS 45D0080 REPLACEMENT PARTSBURNER ASSEMBLY C2801/02/03/04VF REPLACEMENT PARTS LISTBURNER ASSEMBLY AccessoriesREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSE45D0080 45D0080 BASIC WARRANTY LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTY FIVE YEAR WARRANTY