Monessen Hearth C2801VF Electrical Wiring Milli-Volt, Removing Face Plate from Stove, Screws

Page 14
Figure 8 - Removing Face Plate from Stove

ELECTRICAL WIRING (MILLI-VOLT)

INSTALLING THERMOSTAT SENSOR (OPTION SOLD SEPARATELY)

1.Remove the face plate by removing the six screws holding the faceplate in place. This will allow you to pull the faceplate away from the unit about 3" to 4". See Figure 8.

2.Slip the t-stat sensor behind the faceplate. Attach the t-stat sensor to the faceplate with 2 screws provided. Make sure the thermo bulb wire is on the bottom of the t-stat sensor. See Figure 9.

3.Attach wiring harnesses to back of t-stat sensor. See Figure 8. Attach the other ends of the har- ness to either TP/TH and TH on control valve or to existing wiring harness with two (2) 0.250" male spade terminals for remote t-stat operation. See Figure 8, page 13.

�������������

Face Plate

Screws

���

 

��

 

��

 

��

 

��

 

 

 

 

��

 

��

 

 

 

��

 

 

 

��

 

��

Figure 8 - Removing Face Plate from Stove

��

���

 

 

��

 

 

��

 

��

 

 

��

 

 

 

 

 

 

Screws

�����

 

 

 

 

 

 

� �

 

 

 

 

��

 

 

 

 

 

 

��

 

 

��

T-Stat

Wiring

Sensor

Harnesses

 

Knob

Thermo

Bulb

Figure 9 - Installing T-Stat Sensor and Control Knob

14

45D0080

Image 14
Contents WHAT TO DO IF YOU SMELL GAS MODELS C2801VF, C2802VF C2803VF, and C2804VFNatural Gas or Propane/LPG Milli-VoltControl Do not try to light any applianceCONTENTS OWNER IMPORTANT SAFETY INFORMATIONINSTALLER IMPORTANT SAFETY INFORMATION Continued from pageOptional Remote Receiver Off/Pilot/On Knob PRODUCT FEATURESOn/Off Switch Data andOptional Instruction Thermostat Plates Sensor Hi/Lo KnobMAKE SURE YOU HAVE RECEIVED ALL PARTS WHAT YOU WILL NEED FOR INSTALLATIONGETTING STARTED PROPANE / LPG PRODUCT SPECIFICATIONSNATURAL GAS IGNITION CONTROLS•In high traffic areas •In windy or drafty areas GENERAL INSTALLATION INFORMATIONDo not install the heater … CODESGENERAL INSTALLATION INFORMATION BTU/Hr = L1CLEARANCES / HEIGHT REQUIRMENTS Corner InstallationWall Installation Front ViewCONNECTING THE GAS Figure 4 - Gas Connectionpropane/L.P.G. tank can cause an Connecting directly to an unregulatedCONNECTING REMOTE RECEIVER explosionCONNECTING OPTIONAL WALL SWITCH OR THERMOSTAT ELECTRICAL WIRING MILLI-VOLTFigure 7 - Wiring Diagram MillivoltScrews ELECTRICAL WIRING MILLI-VOLTFigure 8 - Removing Face Plate from Stove Figure 10 - Clipping Thermo Bulb into OPERATION OF THERMOSTAT SENSORELECTRICAL WIRING MILLI-VOLT Plastic Cliparound the pilot. This may cause sooting LOG PLACEMENTDO NOT sprinkle volcanic rocks on the logs or a few hours to vent the odorOPERATING INSTRUCTIONS FLAME APPEARANCECHECKING BURNER FLAME CHECKING PILOT FLAMEWHAT TO DO IF YOU SMELL GAS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING INSTRUCTIONS OPERATING INSTRUCTIONS MILLI-VOLTCONTROL LIGHTING INSTRUCTIONSTO TURN OFF GAS TO HEATER MATCH LIGHTING INSTRUCTIONS OPERATING INSTRUCTIONS AND CLEANING AND SERVICINGCLEANING AND SERVICING Description REPLACEMENT PARTS LISTLOGS 45D0080 REPLACEMENT PARTSBURNER ASSEMBLY Accessories REPLACEMENT PARTS LISTBURNER ASSEMBLY C2801/02/03/04VFPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDYPOSSIBLE CAUSE TROUBLESHOOTINGOBSERVED PROBLEM REMEDY45D0080 45D0080 FIVE YEAR WARRANTY LIMITED LIFETIME WARRANTY POLICYLIFETIME WARRANTY BASIC WARRANTY