Monessen Hearth 624WBPF manual Chimney CAP Installation

Page 16

624WBPF Woodburning Fireplace

CHIMNEY CAP INSTALLATION

 

 

 

NOTE: The proper height as previously explained is important to assure proper draft and safety. The chim- ney cap extends the flue outlet four inches above the top of the last section of chimney. This should be kept in mind when determining the proper height for the chimney. The chimney should not be extended more than 90 inches above the supporting roof structure without additional support. In the case of an ‘A’ frame type construction or other steep pitch roofs that require more than 90 inches of chimney above the roof, a support should be attached to the chimney at the 90 inch level that is strong enough to support a wind load of 3Z\, pounds for each inch the chimney extends above 90 inches. The flue outlet must be a minimum of three feet above the point where it penetrates the roof.

CAUTION: Be careful to avoid electrical shock hazard when contacting wires to the metal chimney com- ponents.

1.Extend the regular chimney sections until the top of the chimney is 4” below the total flue height desired. Do not snap the last section of inlet air duct or largest diameter pipe in place until Step 3 is completed.

2.Remove the shingles from around the chimney so that the flashing may be installed, with the upper part of the flashing under the shingles.

3.Set the flashing on the roof. Hold a section of the outside pipe (13” diameter) on the flashing and scribe a line around the flashing, then cut the top off the flashing by cutting 1/4 inch below the scribed line. This should increase the diameter of the flashing outlet sufficiently to allow the flashing to be placed over the chimney. Figure 18

4.Snap the last section of inlet air duct in place and slide the flashing over the chimney. Adjust the chimney to assure that the proper minimum clearances are maintained.

5.Nail the flashing securely in place with eight nails.

6.Seal the crack between the top of the flashing and the chimney with mastic. Leave some excess mastic at this area to be used in step eight. NOTE: Use pliers and wear gloves when performing step seven to minimize the danger of cutting your hands on the edge of the storm collar.

7.Place the storm collar around the chimney and put the collar together like a belt in belt loops. Slide the end of collar under the two loops on the other end with the loops facing up. Overlap the ends of the collar until it is tight against the chimney. Bend the free end of the collar back over the loops to hold the storm collar securely together. The excess end of the storm collar may be trimmed off.

8.Slide the storm collar down snugly against the flashing until the excess mastic left in step six is forced up into the crack between the storm collar and the chimney. This should make the joint between the flashing and the chim- ney watertight.

9.Install the chimney cap by placing the cap into matching parts of the last chimney section. Then punch or drill 1/8 inch diameter holes in the inlet air duct (chimney pipe) where specified on the brackets and fasten it down with the No. 8 screws provided. Do not penetrate the inner stainless steel pipe while installing the screws.

10.Check all the parts of the fireplace, chimney and chimney termination cap to assure that no parts have been dam- aged or bent during installation and that all parts have been installed properly.

NOTE: The metal used for the chimney cap has a rust pro- tective coating but the cut edges of the parts are not pro- tected. To prevent rusting and rust staining of nearby struc- tures, exposed parts of the chimney and chimney cap should be detergent washed and painted with a galvanized primer paint.

Figure 18

Hold 13” Diameter

(Outside) Pipe Vertical

Scribe Line

at Bottom

 

FP1897

Figure 19

 

Chimney Cap

1856O

*36”

Apply Mastic Here

Storm Collar

 

 

Flashing

* or 2’ Above Any Point Within 10’

FP1898

NOTE: RLTCF11L chimney cap is same as RLTCF11 with the exception of a longer telescoping pipe which may be needed for special installations such as chase installa- tions.

16

53D9052

Image 16
Contents Woodburning Peninsula Fireplace Model 624WBPF Congratulations Improper Installation Intended Product Usage624WBPF Woodburning Fireplace Fireplace Dimensions Over carpeting Do not install fireplaceTop View Clearances Single Story Installation with Attic Space Installation PreparationMultiple Story Installation Floor Protection Fireplace Components Model Number DescriptionChimney Installation Fireplace InstallationLocation Selection Chimney Installation Firestop Spacer Installation at Attic LevelFirestop Spacer Installation at Floor Levels Firestop SpacerElbow Installation Offset Installation Sequence Chimney Offset InstallationElbow Offsets Chimney Requirements Offset InstallationsIllustration Key Chimney CAP Installation Chimney CAP Installation Model AK-4 Combustion Air Assembly Outside Combustion Air RecommendationsInstalling Model 403 Duct Connector Typical Methods Outside Air Kit InstallationGAS Appliance Installation Important NoticesGas Line Plumbing Detail Trim Installation FireplaceAdvantages of a Wood Burning Fireplace How To Build a Better FireWhich Woods Are Best? Wood vs. Fossil Fuels Few Words Of CautionFireplace Operation Species Density Heat ValueFuel Storage Chimney MaintenanceDisposal Of Ashes Glass Door Maintenance Fireplace MaintenanceChecklist of Do’s and Dont’s DONT’S Replacement Parts Description Qty624WBPF Woodburning Fireplace 624WBPF Woodburning Fireplace What is Covered and For How Long What is Not CoveredIf Warranty Service is Needed Limitations and ExclusionsMhsc
Related manuals
Manual 1 pages 45.2 Kb

624WBPF specifications

The Monessen Hearth 624WBPF is a groundbreaking gas fireplace designed to deliver warmth, comfort, and an aesthetically pleasing ambiance to any living space. It merges advanced technology with traditional craftsmanship, making it a popular choice amongst homeowners and designers alike.

One of the standout features of the 624WBPF is its high efficiency. Boasting an impressive efficiency rating, this fireplace allows for excellent heat output while minimizing energy consumption. This is particularly advantageous in colder climates, where a reliable and efficient heating source is imperative. The fireplace's innovative design allows it to quickly heat large areas, ensuring that your home remains cozy even on the chilliest days.

The Monessen 624WBPF is equipped with state-of-the-art technology, including an intuitive remote control that allows users to easily adjust flame height and heat settings. This feature not only enhances the user experience but also provides the convenience of operation from the comfort of your couch. Furthermore, the fireplace includes a versatile lighting system, allowing for a range of ambiance options to suit any occasion or mood.

Aesthetically, the 624WBPF does not disappoint. It can be customized with a variety of decorative fronts and surround options to seamlessly blend with your home’s décor. The large viewing area showcases a realistic flame presentation, enhanced by premium log sets or contemporary fire media options that create a stunning visual element in your space.

Safety is also a primary concern with the Monessen Hearth 624WBPF. It features a built-in safety shut-off system that ensures peace of mind when leaving the fireplace unattended. Additionally, an advanced venting system allows for flexible installation options, including direct venting, which helps to maintain indoor air quality while ensuring efficient performance.

Overall, the Monessen Hearth 624WBPF combines function, efficiency, and style, making it an excellent addition to any home. Its features, technologies, and characteristics come together to provide a reliable heating solution that enhances both the comfort and aesthetics of your living environment. With its focus on innovation and design, the 624WBPF is indeed a premier choice for those seeking a modern yet classic fireplace experience.