Monessen Hearth BDV500, BDV600 operating instructions Installation and Operating Instructions

Page 1

BDV SERIES

DIRECT VENT GAS

FIREPLACE

MODELS:

BDV300, BDV400, BDV500, BDV600

INSTALLATION AND OPERATING

INSTRUCTIONS

WARNINGS

IF THE INFORMATION IN THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

WARNING: Improper installation, adjustment, alteration, services or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer, service agency or the gas supplier.

This appliance may be installed in an aftermarket*, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.

*Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer.

DUE TO HIGH TEMPERATURES, THE APPLIANCE SHOULD BE LOCATED OUT OF TRAFFIC AND AWAY FROM FURNITURE AND DRAPERIES.

CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURE AND SHOULD STAY AWAY TO AVOID BURNS OR CLOTHING IGNITION.

Y O U N G C H I L D R E N S H O U L D B E SUPERVISED WHEN THEY ARE IN THE SAME ROOM AS THE APPLIANCE.

CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE.

KEEP THE ROOM AREA CLEAR AND FREE FROM COMBUSTIBLE MATERIALS, GASOLINE, AND OTHER FLAMMABLE VAPORS AND LIQUIDS.

READ BEFORE INSTALLING. SAVE THESE INSTRUCTIONS

Image 1
Contents What to do if YOU Smell GAS Installation and Operating InstructionsContents Installer Important Safety InformationOwner Non-utility gas wells. This Never connect unit to privateGas is commonly known as Wellhead gasProduct Specifications Product Features and Code ApprovalCode Approval Listed Vented GAS Fireplace HeaterInstalling Above 2000 Feet PRE-INSTALLATION InformationOrifice SIZES, Pressures and BTUs Before YOU StartFirebox Framing Fireplace Framing31/2 Fireplace Dimensions81/4 Locating Gas Fireplace Fireplace LocationClearances to Combustibles ClearancesMantel Clearances Securing Fireplace to Floor and Framing Studs Securing Fireplace to Floor or FramingVent Installation Installation InformationInstallation Precautions Finishing MaterialCombustible Clearances for Vent Pipe Vent InstallationAfter conversion to top vent Optional TOP Vent ApplicationConfiguration the 4 100mm flue pipe Should be concentric within the 65/8Installing a Vent System in AN Outside Chase Installation PlanningFor Horizontal Termination For Vertical TerminationMinimum Distances Horizontal Vent Termination LocationFeet HOW to USE the Vent GraphRear Through the Wall Applications Venting InstallationDo not recess vent termination Rear Wall Vent InstallationInto any wall. This will cause a fire hazardSee Figure Horizontal Termination ConfigurationsHorizontal Run Reduction Horizontal Termination ConfigurationBelow Grade Installation Below Grade InstallationsSupport Straps for Horizontal Runs Vertical THROUGH-THE-ROOF ApplicationsFlat Ceiling Installation Installation for Vertical TerminationMinimum Height Cathedral Ceiling InstallationRoof Pitch Feet Meters Installing GAS Piping to Fireplace / Burner System Location Fireplace InstallationCheck GAS Type Gas Connection Electrical Wiring Checking GAS Pressure and Electrical InstallationDo not use open flame to check for Gas leaksRemote Wall Mounted Switch Electrical InstallationSwitch to heater Do not connect wallRemote Wall Switch Electronic Pilot Ignition WiringOptional DC Remote Systems Optional FAN/BLOWER Systems Blower Wiring DiagramGlass Frame Removal Glass RemovalKeep fingers clear. Remove control panel to operate middle Clamp on 500 and 600 unitsRock Wool Placement Final InstallationLOG Placement Lava Rock and Ember PlacementOperating Instructions MILLI-VOLT Leak TestingWhat to do if YOU Smell GAS Initial LightingApproved Leak Testing Method Lighting the Burner Main Burner SwitchPilot Position Operating Instructions Electronic Lighting Electronic IgnitionBURNER, Pilot and Control Compartment Cleaning and MaintenancePilot Flame BurnerGlass Door Vent SystemLogs Rock WoolSymptom Possible Cause Action TroubleshootingStanding Pilot Ignition Troubleshooting Firebox Components Illustrated Parts ListsCC=Cottage Clay CR=Cottage Red Standing Pilot Millivolt Control Description Qty Electronic Ignition Ignition Module Vent Components Illustrated Parts ListDescription Qty BDV300 BDV400 BDV500 BDV600 Special Requirements Special Requirements Five Year Warranty Lifetime WarrantyBasic Warranty

BDV400, BDV500, BDV300, BDV600 specifications

The Monessen Hearth series, comprising the BDV600, BDV300, BDV500, and BDV400 models, stands out in the realm of gas fireplaces. These contemporary designs fuse aesthetic appeal with cutting-edge technology to provide users with a compelling heating solution. Each model offers distinct features while sharing a commitment to quality and performance.

Starting with the BDV600, this fireplace is known for its robust dual burner system that ensures vibrant flames and reliable heat output. Its impressive efficiency rating makes it ideal for energy-conscious consumers. Additionally, the BDV600 features a stunning realistic log set and allows for customization with various decorative media options, giving homeowners the ability to match their personal style.

Moving on to the BDV300, this model is compact yet powerful. It is designed for smaller spaces without sacrificing warmth or ambiance. The BDV300 utilizes advanced technology to enhance flame presence while minimizing energy consumption. The intuitive remote control system adds convenience, allowing users to adjust the flame height and heat settings effortlessly.

The BDV500, a mid-range option, offers an excellent balance of size and efficiency. This model incorporates a versatile installation design, permitting both direct venting and vent-free options. Homeowners appreciate the BDV500's variable speed blower, which helps distribute heat evenly throughout the room. Its sleek interface and easy-to-use controls make it an attractive choice for those looking to upgrade their home heating solutions.

Finally, the BDV400 combines aesthetic beauty with functional performance. This fireplace is equipped with a powerful yet quiet heating system. The BDV400's realistic flame presentation is driven by a unique burner design that creates a lifelike fire experience. Furthermore, its comprehensive safety features ensure peace of mind, including a safety screen and an automatic shut-off system.

All four models emphasize user-friendly design, featuring easy access for maintenance and cleaning. The advanced technologies built into these fireplaces help provide a cleaner burn, reducing pollutants and ensuring compliance with local regulations.

In summary, the Monessen Hearth BDV series—including the BDV600, BDV300, BDV500, and BDV400—offers homeowners a range of stylish and energy-efficient options. With unique features, advanced technologies, and dependable performance, these gas fireplaces take warmth and comfort to new heights, catering to diverse needs and preferences in modern living spaces.