Monessen Hearth BDV400, BDV600, BDV500, BDV300 operating instructions Special Requirements

Page 51

NOTES

SPECIAL REQUIREMENTS CONTINUED

2.APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.

3.SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS.”

4.INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4.

(b)EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:

1.The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and

2.Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes.

(c)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include:

1.Detailed instructions for the installation of the venting system design or the venting system components; and

2.A complete parts list for the venting system design or venting system.

(d)MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems,” the following requirements shall be satisfied by the manufacturer:

1.The identification of each “special venting system” shall include either the listing of the website, phone number or manufacturer's address where the venting system installation instructions can be obtained; and

2.The “special venting systems” shall be Product Approved by the Board, and the instructions provided with that system shall include a parts list and detailed installation instructions.

(e)A copy of all installation instructions for the Product Approved side wall horizontally vented gas fueled equipment and all the venting instructions, parts lists, and/or all design instructions for the venting system shall remain with the appli- ance or equipment at the completion of the installation.

54D0700

51

Image 51
Contents What to do if YOU Smell GAS Installation and Operating InstructionsContents Important Safety Information InstallerOwner Wellhead gas Never connect unit to privateNon-utility gas wells. This Gas is commonly known asListed Vented GAS Fireplace Heater Product Features and Code ApprovalProduct Specifications Code ApprovalBefore YOU Start PRE-INSTALLATION InformationInstalling Above 2000 Feet Orifice SIZES, Pressures and BTUsFirebox Framing Fireplace FramingFireplace Dimensions 31/281/4 Locating Gas Fireplace Fireplace LocationClearances Clearances to CombustiblesMantel Clearances Securing Fireplace to Floor and Framing Studs Securing Fireplace to Floor or FramingFinishing Material Installation InformationVent Installation Installation PrecautionsCombustible Clearances for Vent Pipe Vent InstallationShould be concentric within the 65/8 Optional TOP Vent ApplicationAfter conversion to top vent Configuration the 4 100mm flue pipeFor Vertical Termination Installation PlanningInstalling a Vent System in AN Outside Chase For Horizontal TerminationMinimum Distances Horizontal Vent Termination LocationFeet HOW to USE the Vent GraphRear Through the Wall Applications Venting Installationfire hazard Rear Wall Vent InstallationDo not recess vent termination Into any wall. This will cause aSee Figure Horizontal Termination ConfigurationsHorizontal Run Reduction Horizontal Termination ConfigurationBelow Grade Installation Below Grade InstallationsSupport Straps for Horizontal Runs Vertical THROUGH-THE-ROOF ApplicationsFlat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Minimum HeightRoof Pitch Feet Meters Fireplace Installation Installing GAS Piping to Fireplace / Burner System LocationCheck GAS Type Gas Connection Gas leaks Checking GAS Pressure and Electrical InstallationElectrical Wiring Do not use open flame to check forDo not connect wall Electrical InstallationRemote Wall Mounted Switch Switch to heaterElectronic Pilot Ignition Wiring Remote Wall SwitchOptional DC Remote Systems Optional FAN/BLOWER Systems Blower Wiring DiagramClamp on 500 and 600 units Glass RemovalGlass Frame Removal Keep fingers clear. Remove control panel to operate middleLava Rock and Ember Placement Final InstallationRock Wool Placement LOG PlacementInitial Lighting Leak TestingOperating Instructions MILLI-VOLT What to do if YOU Smell GASApproved Leak Testing Method Main Burner Switch Lighting the BurnerPilot Position Operating Instructions Electronic Lighting Electronic IgnitionBurner Cleaning and MaintenanceBURNER, Pilot and Control Compartment Pilot FlameRock Wool Vent SystemGlass Door LogsTroubleshooting Symptom Possible Cause ActionStanding Pilot Ignition Troubleshooting Firebox Components Illustrated Parts ListsCC=Cottage Clay CR=Cottage Red Standing Pilot Millivolt Control Description Qty Electronic Ignition Ignition Module Vent Components Illustrated Parts ListDescription Qty BDV300 BDV400 BDV500 BDV600 Special Requirements Special Requirements Lifetime Warranty Five Year WarrantyBasic Warranty

BDV400, BDV500, BDV300, BDV600 specifications

The Monessen Hearth series, comprising the BDV600, BDV300, BDV500, and BDV400 models, stands out in the realm of gas fireplaces. These contemporary designs fuse aesthetic appeal with cutting-edge technology to provide users with a compelling heating solution. Each model offers distinct features while sharing a commitment to quality and performance.

Starting with the BDV600, this fireplace is known for its robust dual burner system that ensures vibrant flames and reliable heat output. Its impressive efficiency rating makes it ideal for energy-conscious consumers. Additionally, the BDV600 features a stunning realistic log set and allows for customization with various decorative media options, giving homeowners the ability to match their personal style.

Moving on to the BDV300, this model is compact yet powerful. It is designed for smaller spaces without sacrificing warmth or ambiance. The BDV300 utilizes advanced technology to enhance flame presence while minimizing energy consumption. The intuitive remote control system adds convenience, allowing users to adjust the flame height and heat settings effortlessly.

The BDV500, a mid-range option, offers an excellent balance of size and efficiency. This model incorporates a versatile installation design, permitting both direct venting and vent-free options. Homeowners appreciate the BDV500's variable speed blower, which helps distribute heat evenly throughout the room. Its sleek interface and easy-to-use controls make it an attractive choice for those looking to upgrade their home heating solutions.

Finally, the BDV400 combines aesthetic beauty with functional performance. This fireplace is equipped with a powerful yet quiet heating system. The BDV400's realistic flame presentation is driven by a unique burner design that creates a lifelike fire experience. Furthermore, its comprehensive safety features ensure peace of mind, including a safety screen and an automatic shut-off system.

All four models emphasize user-friendly design, featuring easy access for maintenance and cleaning. The advanced technologies built into these fireplaces help provide a cleaner burn, reducing pollutants and ensuring compliance with local regulations.

In summary, the Monessen Hearth BDV series—including the BDV600, BDV300, BDV500, and BDV400—offers homeowners a range of stylish and energy-efficient options. With unique features, advanced technologies, and dependable performance, these gas fireplaces take warmth and comfort to new heights, catering to diverse needs and preferences in modern living spaces.