Monessen Hearth BDV300, BDV600, BDV500, BDV400 operating instructions Special Requirements

Page 50

NOTES MASSACHUSETTS RESIDENTS ONLY: PLEASE READ AND FOLLOW THESE

SPECIAL REQUIREMENTS

NOTE REGARDING VENTED PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

Any residence with a direct vent product must have a CO detector installed in the residence.

Installation of the fireplace or vented gas log in the State of Massachusetts requires the damper to be permanently removed or welded in the fully open position.

In addition, a naturally vented gas log may not be installed in a bedroom or bathroom in the State of Massachusetts. Flex line installation must not exceed 36 inches and must have a T shutoff valve.

NOTE REGARDING VENT FREE PRODUCTS

This product must be installed by a licensed plumber or gas fitter when installed within the Commonwealth of Massachu- setts.

In addition, vent free products may not be installed in a bedroom or bathroom regardless of size or type in the State of Mas- sachusetts.

Flex line installation must not exceed 36 inches and must have a T shutoff valve.

CARBON MONOXIDE DETECTOR REQUIREMENTS

(2) Revise 10.8.3 by adding the following additional requirements:

(a)For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied:

1.INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors

a.In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.

b.In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be in- stalled.

50

54D0700

Image 50
Contents Installation and Operating Instructions What to do if YOU Smell GASContents Owner Important Safety InformationInstaller Gas is commonly known as Never connect unit to privateNon-utility gas wells. This Wellhead gasCode Approval Product Features and Code ApprovalProduct Specifications Listed Vented GAS Fireplace HeaterOrifice SIZES, Pressures and BTUs PRE-INSTALLATION InformationInstalling Above 2000 Feet Before YOU StartFireplace Framing Firebox Framing81/4 Fireplace Dimensions31/2 Fireplace Location Locating Gas FireplaceMantel Clearances ClearancesClearances to Combustibles Securing Fireplace to Floor or Framing Securing Fireplace to Floor and Framing StudsInstallation Precautions Installation InformationVent Installation Finishing MaterialVent Installation Combustible Clearances for Vent PipeConfiguration the 4 100mm flue pipe Optional TOP Vent ApplicationAfter conversion to top vent Should be concentric within the 65/8For Horizontal Termination Installation PlanningInstalling a Vent System in AN Outside Chase For Vertical TerminationHorizontal Vent Termination Location Minimum DistancesHOW to USE the Vent Graph FeetVenting Installation Rear Through the Wall ApplicationsInto any wall. This will cause a Rear Wall Vent InstallationDo not recess vent termination fire hazardHorizontal Termination Configurations See FigureHorizontal Termination Configuration Horizontal Run ReductionBelow Grade Installations Below Grade InstallationVertical THROUGH-THE-ROOF Applications Support Straps for Horizontal RunsInstallation for Vertical Termination Flat Ceiling InstallationRoof Pitch Feet Meters Cathedral Ceiling InstallationMinimum Height Check GAS Type Fireplace InstallationInstalling GAS Piping to Fireplace / Burner System Location Gas Connection Do not use open flame to check for Checking GAS Pressure and Electrical InstallationElectrical Wiring Gas leaksSwitch to heater Electrical InstallationRemote Wall Mounted Switch Do not connect wallOptional DC Remote Systems Electronic Pilot Ignition WiringRemote Wall Switch Blower Wiring Diagram Optional FAN/BLOWER SystemsKeep fingers clear. Remove control panel to operate middle Glass RemovalGlass Frame Removal Clamp on 500 and 600 unitsLOG Placement Final InstallationRock Wool Placement Lava Rock and Ember PlacementWhat to do if YOU Smell GAS Leak TestingOperating Instructions MILLI-VOLT Initial LightingApproved Leak Testing Method Pilot Position Main Burner SwitchLighting the Burner Lighting Electronic Ignition Operating Instructions ElectronicPilot Flame Cleaning and MaintenanceBURNER, Pilot and Control Compartment BurnerLogs Vent SystemGlass Door Rock WoolStanding Pilot Ignition TroubleshootingSymptom Possible Cause Action Troubleshooting Illustrated Parts Lists Firebox ComponentsCC=Cottage Clay CR=Cottage Red Standing Pilot Millivolt Control Description Qty Electronic Ignition Ignition Module Illustrated Parts List Vent ComponentsDescription Qty BDV300 BDV400 BDV500 BDV600 Special Requirements Special Requirements Basic Warranty Lifetime WarrantyFive Year Warranty

BDV400, BDV500, BDV300, BDV600 specifications

The Monessen Hearth series, comprising the BDV600, BDV300, BDV500, and BDV400 models, stands out in the realm of gas fireplaces. These contemporary designs fuse aesthetic appeal with cutting-edge technology to provide users with a compelling heating solution. Each model offers distinct features while sharing a commitment to quality and performance.

Starting with the BDV600, this fireplace is known for its robust dual burner system that ensures vibrant flames and reliable heat output. Its impressive efficiency rating makes it ideal for energy-conscious consumers. Additionally, the BDV600 features a stunning realistic log set and allows for customization with various decorative media options, giving homeowners the ability to match their personal style.

Moving on to the BDV300, this model is compact yet powerful. It is designed for smaller spaces without sacrificing warmth or ambiance. The BDV300 utilizes advanced technology to enhance flame presence while minimizing energy consumption. The intuitive remote control system adds convenience, allowing users to adjust the flame height and heat settings effortlessly.

The BDV500, a mid-range option, offers an excellent balance of size and efficiency. This model incorporates a versatile installation design, permitting both direct venting and vent-free options. Homeowners appreciate the BDV500's variable speed blower, which helps distribute heat evenly throughout the room. Its sleek interface and easy-to-use controls make it an attractive choice for those looking to upgrade their home heating solutions.

Finally, the BDV400 combines aesthetic beauty with functional performance. This fireplace is equipped with a powerful yet quiet heating system. The BDV400's realistic flame presentation is driven by a unique burner design that creates a lifelike fire experience. Furthermore, its comprehensive safety features ensure peace of mind, including a safety screen and an automatic shut-off system.

All four models emphasize user-friendly design, featuring easy access for maintenance and cleaning. The advanced technologies built into these fireplaces help provide a cleaner burn, reducing pollutants and ensuring compliance with local regulations.

In summary, the Monessen Hearth BDV series—including the BDV600, BDV300, BDV500, and BDV400—offers homeowners a range of stylish and energy-efficient options. With unique features, advanced technologies, and dependable performance, these gas fireplaces take warmth and comfort to new heights, catering to diverse needs and preferences in modern living spaces.