OPTIONS

GVF103-KT - PATENTED CATALYTIC

DOOR INSTALLATION

Notes:

Ornamental insets can not be used in conjunction with the catalytic door

When using a catalytic door, glassed doors must be used on all other side or end openings.

This unique patented catalytic system was designed to provide unparalleled safety and peace of mind. The top of the door contains four catalytic tiles which are designed to filter out combustion gases and limit the carbon monox- ide output. It is likely that with the fireplace in operation, the catalytic tiles will actually scrub the carbon monoxide nor- mally found in the room and reduce it to a lower level. The tiles must not be altered or removed. They are not field serviceable and must be tested annually. The hood sup- plied with the unit must be disgarded and replaced with the hood designed for use with the catalytic door.

The heater with an optional catalytic door in place must not be operated when using any products such as paint, paint thinner, adhesives, etc. These products will perma- nently affect the catalytic tiles’ ability to scrub the air.

FIGURES 35

CURTAIN ROD

 

BRACKET

3.Screw the door hinge onto the heater by first start- ing each of the five ma- chine screws and then tightening all screws.

3

TOP DOOR LATCH

4

BOTTOM DOOR LATCH

DOOR HINGE

1

1.The mesh must be removed if the catalytic door is used. Remove the centre bracket and bend the curtain rod slightly to disengage the rod from either side.

LATCH SCREW

LOCATION

CURTAIN SUPPORT PLATE

2

2.Remove the curtain support plate. Remove the two latch securing screws, already installed, position latch as shown in 4 and re-secure with the screws. A ¼” socket ratchet is recommended for this.

Repeat at the bottom. For location, see 5 .

5

4.& 5. Secure the door using the two latches.

Install the appropriate hood by hooking it over the top lip of the door assembly.

The heater must not be used when the hood is removed.

DOOR OPENING AND CLOSING

The upper louvres must be removed to allow the catalytic door to be opened or closed. To access the lower door latch, open the valve control door. Release the top and bottom door latches, located at the right side of the door.

Care must be taken when closing and opening the cata- lytic door to avoid damaging the catalytic tiles.

W415-0319 / E / 01.17.07

Image 16
Contents W415-0319 / E Table of Contents Conditions and Limitations General Instructions General InformationCarbon Monoxide Poisoning MAY Lead to Death American Nation Standards Institute IncCombustion and Ventilation AIR Provisions InstallationDetermining Confined or Unconfined Space GAS Installation Wire Size MAX. LengthUsing Door Option Do not USE Open FlameSided Countertop / BAR Installation Peninsula Installation ProcedureFraming Brick Panel Installation FacingFinishing RetainerOPEN-END Installation Procedure = 25¼ minus finishing material thickness each sideFraming Facing SEE-THROUGH Installation ProcedureTail Island Installation Procedure Locating Pins LOG PlacementFinishing Mantle Installation Glowing EmbersHood Charcoal EmbersL36 Louvre Installation Heat Shield STAND-OFF Removal Logo PlacementUpper Louvres Lower LouvresGVF103-KT Patented Catalytic Door Installation OptionsDoor Opening and Closing TOP Door Latch Bottom Door LatchOptional Blower Installation WhiteOperation / Maintenance For Your Safety Read Before LightingWhat to do if YOU Smell GAS Lighting InstructionsMaintenance Catalytic Tile MaintenanceOxygen Depletion Sensor Pilot Cleaning Venturi AdjustmentReplacements Accessories# Part No. Description Components Unique to Peninsula UnitW415-0319 / E Trouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History