BRICK PANEL INSTALLATION
Install the base panels as illustrated in steps
FIGURES 9a-e
STEP 1
STEP 2
STEP 3
STEP 4
RETAINER
STEP 5
DETAIL5
9
FACING
Combustible materials may be installed flush with the front of the fireplace but must not cover any of the black face- areas of the fireplace.
It is not necessary to install a hearth extension with this fireplace system.
When roughing in the fireplace, raise the fireplace to ac- commodate for the thickness of the finished floor materi- als, i.e. tile, carpeting, hard wood, which if not planned for will interfere with the opening of the lower access door and
the installation of many decorative flashing accessories.
Objects placed in front of the fireplace should be kept a minimum of 48" away from the glass front faces of the fireplace.
FIGURE 10
DRYWALL
DRYWALL
4" MIN
FINISHING