Napoleon Fireplaces BGNV40-P, BGNV40-N manual Optional Blower Installation

Page 18

18

OPTIONAL BLOWER INSTALLATION

THIS BLOWER IS NOT SUITABLE FOR THE 4 SIDED ISLAND INSTALLATION.

in accordance with local codes. In the absence of local codes, use the current CSA C22.1 CANADIAN ELECTRICAL CODE in Canada or the ANSI/NFPA 70 NATIONAL ELECTRICAL CODE in the United States.

Remove

the

 

blower from

its

 

mounting bracket

 

and attach to the

 

bracket supplied

 

with the fireplace.

FIGURE40

This bracket

is

 

found secured on the mounting stud located at the bot- tom of the vent side wall.

FIGURE41

FIGURE42

The blower bracket contains two holes that allow the blower to be positioned away from the intended gas supply hole.

Position the vibration reducing pad, centred, onto the threaded stud, piercing a hole into the pad. The blower must be able to be positioned entirely onto the pad.

Tilt the blower onto its side and slide it past the controls. Position the blower under the clip and onto the stud. Se- cure with a wing nut.

THERMODISC WIRES TO BLOWER

THERMODISC BRACKET

FIGURE44

Remove the thermodisc bracket from the top of the firebox.

Remove the thermodisc from the bracket supplied in the blower kit and install the thermodisc into the fireplace bracket. Then replace the bracket in the location it was removed.

Connect the two ends of the unattached wires by the bracket to the thermodisc.

Connect the opposite ends of the wires to the red and black leads of the blower harness.

The wire harness provided in this kit is a universal har- ness. When installed, ensure that any excess wire is contained, preventing it from making contact with mov- ing or hot objects.

Drywall dust will penetrate into the blower bearings, causing irreparable damage. Care must be taken to prevent drywall dust from coming into contact with the blower or its compartment. Any damage resulting from this condition is not covered by the warranty policy.

Because the blower is thermally activated, when turned on, it will automatically start approximately 10 minutes after lighting the fireplace and will run for approximately 30 - 45 minutes after the fireplace has been turned off. Use of the fan increases the output of heat.

FIGURE43

W415-0320/D/01.06.07

Image 18
Contents W415-0320/D/01.16.07 W415-0320 / D What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Introduction General Instructions General InformationCare of GLASS, and Plated Parts Dimensions FIGURES1a-dVenting Venting Safety SwitchHigh Limit Switch Venting Action CheckVenting Peninsula Installation ProcedureCountertop / BAR Installation FramingBrick Panel Installation FacingFinishing OPEN-END Installation Procedure = 251/4 minus finishing material thickness each sideSEE-THROUGH Installation Procedure FIGURES16a-cIsland Installation Procedure GAS Installation Proceed once the vent installation is completeMantle Installation FinishingHeat Shield STAND-OFF Removal LOG Placement Locating Pins PilotGlowing Embers L36 Louvre Installation Logo PlacementCharcoal Embers END Door Installation Door Steel LIPOptional Blower Installation Operation / Maintenance MaintenanceAdjustments Pilot Burner AdjustmentVenturi Adjustment Replacements Components Common to ALL UnitsW415-0320/D/01.06.07 Accessories Part No. DescriptionTrouble Shooting Guide Symptom Problem Test SolutionDo not Clean Glass When HOT Fireplace Service History Page W415-0320/D/01.06.07

BGNV40-N, BGNV40-P specifications

Napoleon Fireplaces BGNV40-P and BGNV40-N are versatile and stylish heating solutions designed for those seeking both functionality and aesthetic appeal in their living spaces. These fireplace inserts stand out not only for their elegant designs but also for their advanced features and technologies that enhance the overall user experience.

One of the main features of the BGNV40-P and BGNV40-N is their dual-fuel capability, allowing homeowners to choose between natural gas and propane. This flexibility ensures that users can select the fuel type that best suits their preferences and availability. The fireplace inserts also boast a high-efficiency rating, ensuring that a significant amount of the fuel is converted into usable heat, making them an economical choice for home heating.

The design of the BGNV40-P (propane) and BGNV40-N (natural gas) is another noteworthy aspect. Both models feature a sleek, contemporary style that can seamlessly blend with various interior decors, from modern to traditional. Large viewing areas facilitated by high-quality tempered glass provide a spectacular view of the flames, creating a cozy and inviting atmosphere. The clean, linear design further enhances the visual appeal of the fireplace, making it a stunning focal point in any room.

In terms of technology, Napoleon incorporates innovative features such as the advanced electronic ignition system, which ensures reliable startups of the fireplace, even during power outages. The variable heat output allows users to adjust the flame height and heat output according to their needs, promoting optimal comfort in any weather condition.

Safety is also a prime consideration in the BGNV40-P and BGNV40-N models. With built-in safety features like an automatic shut-off, the fireplaces detect any irregularities and safely turn off if necessary. The units are equipped with a ceramic glass front that withstands high temperatures, ensuring safety while enjoying the warmth of the fire.

In conclusion, the Napoleon Fireplaces BGNV40-P and BGNV40-N are exceptional choices for those who value efficiency, style, and safety in their home heating solutions. Their dual-fuel capability, high efficiency, aesthetic design, and advanced technologies make them stand out in the world of fireplaces, providing both warmth and elegance to any living space.