Napoleon Fireplaces BGNV40-N, BGNV40-P manual Do not Clean Glass When HOT

Page 25

 

 

 

 

 

 

 

25

 

 

 

 

 

 

SYMPTOM

PROBLEM

 

TEST SOLUTION

 

 

 

 

 

 

 

 

 

 

Pilot

goes

out

Gas piping is undersized.

-

turn on all gas appliances and see if pilot flame flutters, dimin-

 

while standing;

 

ishes or extinguishes, especially when main burner ignites. Monitor

 

Main burner is in

 

appliance supply working pressure.

 

'OFF' position.

 

-

check if supply piping size is to code. Correct all undersized piping.

 

Flames

are

con-

Unit is over-fired or under-

-

check pressure readings:

 

 

sistently too large

fired.

Inlet pressure can be checked by turning screw (A) counter-clock-

 

or

too

small.

 

wise 2 or 3 turns and then placing pressure gauge tubing over the

 

Carboning occurs.

 

test point. Gauge should read 7" (minimum 4.5") water column for

 

 

 

 

 

 

natural gas or 13" (11" minimum) water column for propane. Check

 

 

 

 

 

 

that main burner is operating on "HI".

Outlet pressure can be checked the same as above using screw

(B). Gauge should read 3.5" water column for natural gas or 10" water column for propane. Check that main burner is operating on "HI".

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL. DO NOT OVERTORQUE. Leak test with a soap and water solution.

Carbon is being

deposited on glass, logs or com- bustion chamber surfaces.

Air shutter has become

-

ensure air shutter opening is free of lint or other obstructions.

blocked

 

 

 

 

 

Flame is impinging on the

-

check that the logs are correctly positioned.

logs or combustion cham-

-

open air shutter to increase the primary air.

ber.

-

check the input rate: check the manifold pressure and orifice size

 

as specified by the rating plate values.

 

- check to ensure proper venting action

White / grey film Sulphur from fuel is being

forms.deposited on glass, logs or combustion chamber sur- faces.

-clean the glass with a recommended gas fireplace glass cleaner.

DO NOT CLEAN GLASS WHEN HOT.

If deposits are not cleaned off regularly, the glass may become permanently marked.

Exhaust

fumes

 

Fireplace is spilling.

- check for chimney blockage

smelled in

room,

 

 

- check that chimney is installed to building code.

headaches.

 

 

- room is in negative pressure; increase fresh air supply.

 

 

 

 

Main burner flame

Not enough combustion air

- room is in negative pressure; increase fresh air supply

is a blue,

lazy,

 

 

 

transparent flame.

 

 

 

 

 

 

 

 

Remote

wall

 

Wall switch is mounted up-

- reverse.

switch is in "OFF"

 

side down

 

position;

main

 

Remote wall switch is - replace.

burner comes on

 

grounding.

 

when gas knob is

 

 

 

 

Remote wall switch wire is

- check for ground (short); repair ground or replace wire.

turned to "ON" po-

 

sition.

 

 

grounding.

 

 

 

Faulty valve.

- replace.

 

 

 

 

 

 

 

 

 

 

 

 

 

W415-0320 / D / 01.06.07

Image 25
Contents W415-0320/D/01.16.07 W415-0320 / D What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General Information IntroductionCare of GLASS, and Plated Parts FIGURES1a-d DimensionsHigh Limit Switch Venting Safety SwitchVenting Venting Action CheckCountertop / BAR Installation Peninsula Installation ProcedureVenting FramingFacing Brick Panel InstallationFinishing = 251/4 minus finishing material thickness each side OPEN-END Installation ProcedureFIGURES16a-c SEE-THROUGH Installation ProcedureIsland Installation Procedure Proceed once the vent installation is complete GAS InstallationFinishing Mantle InstallationHeat Shield STAND-OFF Removal Locating Pins Pilot LOG PlacementLogo Placement Glowing Embers L36 Louvre InstallationCharcoal Embers Door Steel LIP END Door InstallationOptional Blower Installation Maintenance Operation / MaintenancePilot Burner Adjustment AdjustmentsVenturi Adjustment Components Common to ALL Units ReplacementsW415-0320/D/01.06.07 Part No. Description AccessoriesSymptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History Page W415-0320/D/01.06.07

BGNV40-N, BGNV40-P specifications

Napoleon Fireplaces BGNV40-P and BGNV40-N are versatile and stylish heating solutions designed for those seeking both functionality and aesthetic appeal in their living spaces. These fireplace inserts stand out not only for their elegant designs but also for their advanced features and technologies that enhance the overall user experience.

One of the main features of the BGNV40-P and BGNV40-N is their dual-fuel capability, allowing homeowners to choose between natural gas and propane. This flexibility ensures that users can select the fuel type that best suits their preferences and availability. The fireplace inserts also boast a high-efficiency rating, ensuring that a significant amount of the fuel is converted into usable heat, making them an economical choice for home heating.

The design of the BGNV40-P (propane) and BGNV40-N (natural gas) is another noteworthy aspect. Both models feature a sleek, contemporary style that can seamlessly blend with various interior decors, from modern to traditional. Large viewing areas facilitated by high-quality tempered glass provide a spectacular view of the flames, creating a cozy and inviting atmosphere. The clean, linear design further enhances the visual appeal of the fireplace, making it a stunning focal point in any room.

In terms of technology, Napoleon incorporates innovative features such as the advanced electronic ignition system, which ensures reliable startups of the fireplace, even during power outages. The variable heat output allows users to adjust the flame height and heat output according to their needs, promoting optimal comfort in any weather condition.

Safety is also a prime consideration in the BGNV40-P and BGNV40-N models. With built-in safety features like an automatic shut-off, the fireplaces detect any irregularities and safely turn off if necessary. The units are equipped with a ceramic glass front that withstands high temperatures, ensuring safety while enjoying the warmth of the fire.

In conclusion, the Napoleon Fireplaces BGNV40-P and BGNV40-N are exceptional choices for those who value efficiency, style, and safety in their home heating solutions. Their dual-fuel capability, high efficiency, aesthetic design, and advanced technologies make them stand out in the world of fireplaces, providing both warmth and elegance to any living space.