Napoleon Fireplaces BGNV40-N Venting Safety Switch, High Limit Switch, Venting Action Check

Page 7

7

VENTING

This is a vented appliance and must be connected to a chimney in accordance with the current installation codes. In absence of local codes, install to the current National Fuel Gas Code, ANSI Z223.1, or the current CAN/CGA B149, Installation Codes. This model can be common-vented.

A minimum five inch diameter (5"ø) B-vent or class A vent is required. A minimum 5' vent height is required. Secure the B-vent to the exhaust collar on the stove top with 3 screws. In cold climates, the use of a B-vent and an insulated chase is recommended.

VENTING SAFETY SWITCH

This thermally activated switch, located in front of the draft hood, senses an increase in temperature and acts as a safety shut-off (See 'A' below). It shuts down the gas to the main burner in the event of a severe downdraft of air or a blocked or disconnected chimney flue. If the flue is blocked or has no "draw", the safety switch will automatically shut off the supply of gas to the main burner within 10 minutes.

HIGH LIMIT SWITCH

This thermally activated switch, located in front of the draft hood, senses an increase in temperature and acts as a safety shut-off (See 'A' below). It shuts down the gas to the main burner in the unlikely event of the unit overheating. The HI Limit switch will automatically reset after the unit has cooled down, resuming gas flow to the main burner.

VENT SAFETY

HIGH LIMIT

SWITCH

SWITCH

 

THERMOSTAT OR

 

WALL SWITCH

 

FIGURE3

VALVE

VENTING ACTION CHECK

This switch must be manually reset by depressing the plunger. Refer to Figure 2.

Tampering with the safety switch can result in car- bon monoxide poisoning and possible death.

The one wire running from the vent safety switch is attached to terminal 1 of the valve (See 'B' below). The other wire (laying loose in the valve control area) may be attached to a wall switch or thermostat.

HI LIMIT

SWITCH

PLUNGER

A

A test for correct venting action must be made before the installed unit can be left with the customer.

Follow the procedure below:

1.Close all doors and windows in the room / start ex- haust fans in the home / turn the fireplace blower off (if so equipped).

2.Set controls to "high" and light the unit.

3.Wait 5 minutes. Light a match and hold to the front of the draft hood. FIGURES 4 & 5.

FIGURE4

Venting action is satisfactory, if smoke and flames are drawn into the draft hood.

FIGURE2

B

FIGURE5

Venting action is unsatisfactory, if the smoke spills back, and the flame splays outward. If venting action is unsatisfactory, turn off the unit, wait 10 minutes and try again. If the smoke is still not drawn into the draft hood, turn the unit off and check for vent blockage or restriction. If necessary, consult with a quali- fied inspector.

The Vent Safety or Hi Limit switches must not be adjusted or disabled.

In the event that either switch or any associated parts are exchanged, only original manufacturer's parts may be used.

W415-0320 / D / 01.06.07

Image 7
Contents W415-0320/D/01.16.07 W415-0320 / D What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty General Instructions General Information IntroductionCare of GLASS, and Plated Parts FIGURES1a-d DimensionsVenting Action Check Venting Safety SwitchHigh Limit Switch VentingFraming Peninsula Installation ProcedureCountertop / BAR Installation VentingFacing Brick Panel InstallationFinishing = 251/4 minus finishing material thickness each side OPEN-END Installation ProcedureFIGURES16a-c SEE-THROUGH Installation ProcedureIsland Installation Procedure Proceed once the vent installation is complete GAS InstallationFinishing Mantle InstallationHeat Shield STAND-OFF Removal Locating Pins Pilot LOG PlacementLogo Placement Glowing Embers L36 Louvre InstallationCharcoal Embers Door Steel LIP END Door InstallationOptional Blower Installation Maintenance Operation / MaintenancePilot Burner Adjustment AdjustmentsVenturi Adjustment Components Common to ALL Units ReplacementsW415-0320/D/01.06.07 Part No. Description AccessoriesSymptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History Page W415-0320/D/01.06.07

BGNV40-N, BGNV40-P specifications

Napoleon Fireplaces BGNV40-P and BGNV40-N are versatile and stylish heating solutions designed for those seeking both functionality and aesthetic appeal in their living spaces. These fireplace inserts stand out not only for their elegant designs but also for their advanced features and technologies that enhance the overall user experience.

One of the main features of the BGNV40-P and BGNV40-N is their dual-fuel capability, allowing homeowners to choose between natural gas and propane. This flexibility ensures that users can select the fuel type that best suits their preferences and availability. The fireplace inserts also boast a high-efficiency rating, ensuring that a significant amount of the fuel is converted into usable heat, making them an economical choice for home heating.

The design of the BGNV40-P (propane) and BGNV40-N (natural gas) is another noteworthy aspect. Both models feature a sleek, contemporary style that can seamlessly blend with various interior decors, from modern to traditional. Large viewing areas facilitated by high-quality tempered glass provide a spectacular view of the flames, creating a cozy and inviting atmosphere. The clean, linear design further enhances the visual appeal of the fireplace, making it a stunning focal point in any room.

In terms of technology, Napoleon incorporates innovative features such as the advanced electronic ignition system, which ensures reliable startups of the fireplace, even during power outages. The variable heat output allows users to adjust the flame height and heat output according to their needs, promoting optimal comfort in any weather condition.

Safety is also a prime consideration in the BGNV40-P and BGNV40-N models. With built-in safety features like an automatic shut-off, the fireplaces detect any irregularities and safely turn off if necessary. The units are equipped with a ceramic glass front that withstands high temperatures, ensuring safety while enjoying the warmth of the fire.

In conclusion, the Napoleon Fireplaces BGNV40-P and BGNV40-N are exceptional choices for those who value efficiency, style, and safety in their home heating solutions. Their dual-fuel capability, high efficiency, aesthetic design, and advanced technologies make them stand out in the world of fireplaces, providing both warmth and elegance to any living space.