Napoleon Fireplaces BGNV40-N, BGNV40-P manual Table of Contents

Page 3

3

TABLE of CONTENTS

Pg 2-6 INTRODUCTION

Warnings and Safety Precautions

Warranty

General Instructions

General Information

Care of Glass & Plated Parts

Dimensions

7VENTING

Vent Safety Switch

High Limit Switch

Venting Action

13 GAS SUPPLY CONNECTION

14-17 FINISHING

Mantle Height Locations Heat shield stand-off removal Log Placement/Charcoal Embers Logo Placement

Door Opening and Closing Upper Louvre Bracket and Hood

Lower Louvre Bracket and Hinge Screen Louvre Installation

End Door Installation

8-9PENINSULAINSTALLATIONPROCEDURE

18

OPTIONAL BLOWER INSTALLATION

19

OPERATION / MAINTENANCE

 

Framing

 

Bar / Countertop Installation

 

Operating Instructions

 

Brick Panel Installation

 

Maintenance

 

Facing

20

ADJUSTMENTS

10 OPENENDINSTALLATIONPROCEDURE

 

Pilot Burner Adjustment

 

Framing

 

Venturi Adjustments

 

Brick Panel Installation

21-22 REPLACEMENTS

 

Facing

 

Ordering Replacement Parts

11

SEE-THRU INSTALLATION PROCEDURE

 

 

Replacement Parts

 

Framing

23

ACCESSORIES

 

Brick Panel Installation

 

Facing

24-25 TROUBLE SHOOTING GUIDE

12

ISLAND INSTALLATION PROCEDURE

26

SERVICE HISTORY

 

Framing

 

 

 

Brick Panel Installation

Facing

PLEASE RETAIN THIS MANUAL FOR FUTURE REFERENCE

WARNING

Do not burn wood or other materials in this fireplace.

Adults and especially children should be alerted to the hazards of high surface temperatures and should stay away to avoid burns or clothing ignition. Supervise young children when they are in the same room as the fireplace.

Due to high temperatures, the fireplace should be located out of traffic and away from furniture and draperies.

Clothing or other flammable material should not be placed on or near the fireplace.

Any safety screen or guard removed for servicing must be replaced prior to operating the fireplace.

It is imperative that the control compartments, burners and circulating blower and its passageway in the fireplace and venting system are kept clean. The fireplace and its venting system should be inspected before use and at least annually by a qualified service person. More frequent cleaning may be required due to excessive lint from carpeting, bedding material, etc. The fireplace area must be kept clear and free from combustible materials, gasoline and other flammable vapours and liquids.

Under no circumstances should this fireplace be modified.

This fireplace must not be connected to a chimney flue pipe serving a separate solid fuel burning appliance.

Do not use this fireplace if any part has been under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

Do not operate the fireplace with the glass door removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person.

Do not strike or slam shut the fireplace glass door.

This fireplace uses and requires a fast acting thermocouple. Replace only with a fast acting thermocouple sup- plied by Wolf Steel Ltd.

NOTE: changes, other than editorial, are denoted by a vertical line in the margin.

W415-0320 / D / 01.06.07

Image 3
Contents W415-0320/D/01.16.07 W415-0320 / D What to do if YOU Smell GAS Table of Contents Napoleon GAS Fireplace Presidents Lifetime Limited Warranty Introduction General Instructions General InformationCare of GLASS, and Plated Parts FIGURES1a-d DimensionsVenting Action Check Venting Safety SwitchHigh Limit Switch VentingFraming Peninsula Installation ProcedureCountertop / BAR Installation VentingBrick Panel Installation FacingFinishing = 251/4 minus finishing material thickness each side OPEN-END Installation ProcedureFIGURES16a-c SEE-THROUGH Installation ProcedureIsland Installation Procedure Proceed once the vent installation is complete GAS InstallationMantle Installation FinishingHeat Shield STAND-OFF Removal Locating Pins Pilot LOG PlacementGlowing Embers L36 Louvre Installation Logo PlacementCharcoal Embers Door Steel LIP END Door InstallationOptional Blower Installation Maintenance Operation / MaintenanceAdjustments Pilot Burner AdjustmentVenturi Adjustment Components Common to ALL Units ReplacementsW415-0320/D/01.06.07 Part No. Description AccessoriesSymptom Problem Test Solution Trouble Shooting GuideDo not Clean Glass When HOT Fireplace Service History Page W415-0320/D/01.06.07

BGNV40-N, BGNV40-P specifications

Napoleon Fireplaces BGNV40-P and BGNV40-N are versatile and stylish heating solutions designed for those seeking both functionality and aesthetic appeal in their living spaces. These fireplace inserts stand out not only for their elegant designs but also for their advanced features and technologies that enhance the overall user experience.

One of the main features of the BGNV40-P and BGNV40-N is their dual-fuel capability, allowing homeowners to choose between natural gas and propane. This flexibility ensures that users can select the fuel type that best suits their preferences and availability. The fireplace inserts also boast a high-efficiency rating, ensuring that a significant amount of the fuel is converted into usable heat, making them an economical choice for home heating.

The design of the BGNV40-P (propane) and BGNV40-N (natural gas) is another noteworthy aspect. Both models feature a sleek, contemporary style that can seamlessly blend with various interior decors, from modern to traditional. Large viewing areas facilitated by high-quality tempered glass provide a spectacular view of the flames, creating a cozy and inviting atmosphere. The clean, linear design further enhances the visual appeal of the fireplace, making it a stunning focal point in any room.

In terms of technology, Napoleon incorporates innovative features such as the advanced electronic ignition system, which ensures reliable startups of the fireplace, even during power outages. The variable heat output allows users to adjust the flame height and heat output according to their needs, promoting optimal comfort in any weather condition.

Safety is also a prime consideration in the BGNV40-P and BGNV40-N models. With built-in safety features like an automatic shut-off, the fireplaces detect any irregularities and safely turn off if necessary. The units are equipped with a ceramic glass front that withstands high temperatures, ensuring safety while enjoying the warmth of the fire.

In conclusion, the Napoleon Fireplaces BGNV40-P and BGNV40-N are exceptional choices for those who value efficiency, style, and safety in their home heating solutions. Their dual-fuel capability, high efficiency, aesthetic design, and advanced technologies make them stand out in the world of fireplaces, providing both warmth and elegance to any living space.