Vermont Casting 2478 Prefabricated Chimneys, Chimney Height, Chimney Size, Two Types of Connector

Page 5

Prefabricated Chimneys

A prefabricated metal chimney must be one tested and listed for use with solid-fuel burning appliances.

A horizontal connector run should be inclined 1/4” per foot (20 mm per meter) from the stove toward the chimney. The recommended maximum length of a hori- zontal run is 3 feet (1m) and the total length of chimney connector should be no longer than 8 feet (2.5m).

Chimney Height

For proper draft and good performance, the chimney should extend at least 16’ (5 m) above the flue collar of the stove.

The chimney must also extend at least 3’ (914 mm) above the highest point where it passes through a roof, and at least 2’ (610 mm) higher than any portion of a building within 10’ (3 m). (Fig. 2)

DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE.

 

0 To 10'

 

 

2' Min. 3'

0 To 10'

 

Min.

 

 

 

2' Min. 3'

 

 

Min.

 

Reference

 

 

Point

 

 

 

AC246

Fig. 3

The 2/3/10 rule for chimneys.

Chimney Size

The Model 2478 heater should be vented into a ma- sonry chimney with a square flue with nominal flue size of 8” x 8” (203 x 203 mm), or a round flue with nominal flue size of 6” (152 mm).

Chimney liners larger than 8” x 12” (203 x 305 mm) may promote rapid cooling of smoke and reduction in draft, especially if they are located outside the home. These large chimneys may need to be insulated or have their flues relined for proper stove performance.

Accessories to help make the connection between stainless steel chimney liners and the stove are avail- able through your local dealer.

Dutchwest Non-Catalytic Convection Heater

Guidelines for Installing the Chimney Connector

The chimney connector is the single-wall pipe, or listed and approved double-wall pipe that connects the stove to the chimney. The chimney itself is a masonry or prefabricated structure that encloses the flue. Chimney connectors are used only to make the connection from the stove to the chimney.

Do not pass the chimney connector through a combus- tible wall, floor, or ceiling, through an attic or roof space, or through a closet or similar concealed space. If pas- sage through a combustible wall is unavoidable, follow the recommendations in the following section on Wall Pass-Throughs. Keep the passage as short and direct as possible, with no more than two 90 degree turns.

Two Types of Connector

You may use either a single-wall steel connector of the size and gauge described below, or a listed and ap- proved double-wall connector.

Single-Wall Connector

The single-wall chimney connector should be made of 24 gauge or heavier steel, and must have a minimum internal diameter of 6” (150 mm) for model 2478.

Install single-wall chimney connector not less than 18” (450 mm) from the ceiling.

In cathedral ceiling installations, extend the prefabri- cated chimney downward to within 8 feet (2.5 meters) of the stove. The entire chimney connector should be exposed and accessible for inspection and cleaning.

Do not use galvanized chimney connector; it cannot withstand the high temperatures that can be reached by smoke and exhaust gases and it may release toxic fumes under high heat.

Chimney

Flue Liner

 

Elbow

Flue

 

Thimble

Slip Pipe

Standard Connector

Flue Collar

Floor Protector

ST418

Fig. 4 Sections of a steel chimney connector of at least 24 gauge thickness are fastened together with screws to connect the stove to the chimney.

30002278

5

Image 5
Contents Non-Catalytic Convection Heater Model Table of Contents Accessories Model SpecificationsMasonry Chimneys InstallationChimney Types Two Types of Connector Guidelines for Installing the Chimney ConnectorSingle-Wall Connector Prefabricated ChimneysSecuring the Connector to a Prefabricated Chimney Double-Wall ConnectorAssembling Single-Wall Chimney Connector Fireplace Installations Above the Fireplace Securing the Connector to a Masonry ChimneyFreestanding Installations Wall Pass-Throughs Fireplace Installations Through the FireplaceCanada Floor ProtectionProcedure Fireplace InstallationsClearances Fireplace Installation ClearancesKeep the Stove a Safe Distance From Surrounding Materials Safe Ways to Reduce ClearancesClearance Chart Reference Diagrams Designing a Safe InstallationChimney Connector Clearance Corner Parallel Installations Stove Clearance Side Rear3Right Side OnlyDutchwest Convection Heater Model Corner Parallel Installations Chimney Connector Side RearDutchWest Non-Catalytic Convection Heater Model #2478 Wall Heat Shield DimensionsAttach the Legs and Heat Shield AssemblyUnpack the Parts Fan Kit Installation Operation Heater Controls and Features Air ControlLoad Doors Damper Function Successful Wood BurningBurn Only High-Quality Fuel Break-in Fires Use the Air Control Settings That Work Best for YouHow to Build and Maintain a Wood Fire Loading Wood Reloading and Reviving the Fire Lighting the FireSafe Ash Handling Remove Ashes FrequentlyCleaning the Glass MaintenanceAdjust the Door Latch Test and Repair the Door GasketsAvoid Damaging the Glass Door Panel Damper AdjustmentPrimary Air Control Adjustment Maintenance Schedule Stove Cleaning the Chimney SystemInspect Regularly, Clean As Required TWO Weeks Draft Management Single Venting Draft TestingFuel CreosoteConclusion Dutchwest Convection Heater Dutchwest Convection Heater Months, whichever is longer Limited Lifetime Warranty

2478 specifications

Vermont Castings 2478 is a premium wood-burning stove that embodies quality craftsmanship and efficiency, making it a top choice for homeowners who prioritize both style and functionality. Renowned for its durability and timeless design, the 2478 model is part of the Vermont Castings line, a brand synonymous with excellence in the world of heating appliances.

One of the standout features of the 2478 is its impressive heating capacity. It can efficiently heat spaces of up to 2,100 square feet, making it suitable for large living areas or even small homes. This capability is complemented by its easy-to-use, user-friendly interface, which allows for intuitive operation and precise temperature control.

The 2478 employs advanced Catalytic Combustion technology, which optimizes fuel efficiency while significantly reducing emissions. This technology ensures that the stove burns wood cleanly and effectively, maximizing heat output and minimizing the environmental impact. The catalytic converter enhances the combustion process, providing a longer burn time and requiring less frequent refueling.

In terms of construction, the Vermont Castings 2478 features a robust cast iron body that not only contributes to its aesthetic appeal but also provides exceptional heat retention. The stove is built to last, designed to withstand high temperatures while delivering consistent warmth. The cast iron grates and firebox contribute to excellent heat distribution, creating a cozy atmosphere throughout the room.

Another notable characteristic is the large glass door that offers a beautiful view of the flames, adding a visual focal point to any space. The air wash system keeps the glass clean, allowing for an unobstructed view of the fire. A variety of finishes are available, allowing homeowners to choose a style that best fits their décor, from classic black to rich enamel colors.

The Vermont Castings 2478 is also designed with safety in mind. It includes features such as an adjustable air control system for improved combustion management and a built-in heat shield that protects surrounding areas from excessive heat.

In summary, the Vermont Castings 2478 is a highly efficient, stylish wood-burning stove that provides warmth and comfort in a reliable and environmentally responsible manner. With its combination of advanced technology, durable construction, and elegant design, the 2478 is a worthy investment for any home. Whether you're seeking to enhance your living space or reduce heating costs, this stove stands out as a classic choice in the realm of heating solutions.