Vermont Casting G400 owner manual Inspection, Cleaning of main burner and orifice

Page 14

flltrlN I ErrttrNvs

INSTrUGTIONS

1.Periodicvisualchecksofthepilotshouldbeconducted

lo ensurethat the flameis presentexcgptwhenthe valvecontrolknobis in the "OFF" position.-

2.Periodicallyremovethe logsfromthe grateassembly and vacuumany looseparticlesfromthe grateand burnerareas.

GAS CONTROL

TYPICAL FLAME PATTERN SHOWING

 

VIEW OF PILOT FLAME

AURNER (A) AND CARRY DOWN POFTS

(B)

FROM ABOVE

 

3.Allcomponentpartsareavailabledirectlythroughthe manufacturerWrite.or phone.

CenturyHeating 330HumberlineDrive,Etobicoke Ontario,Canada,MgW1R5

1-800-836-1210UnitedStatesWattsLine 1-416-798-2800Canada

installationand all repairsshouldbe done by a qualifiedservicepersonThe. applianceshouldbe inspectedbeforeuse and at leastannuallyby a quititiea serviceperson.lt is imperativethat controlcompartments,burnersand circulatin-airg passageway'softhe appliancebe kgpJclean.More ireque-ntclianing may be requireddue.to exces' sivdlint fromcarpeting,beddingmaterialetc.

5. Disconnectallpowerto unitbeforeservicing'

WARiltNG: DO NOr ADJUSTTHE GASORIFICEKEEP. .AREACLEARAND FREEFROM COMBUSTIBLEMATERIALS,GASOLINEANDOTHERFLAMMABLEVAPOURSANDLIQUIDS.

inspection

-Pilotand mainburnerflamesshouldbe checkedvisuallyeachmonth.

-Checkand cleanthe mainburneroncea year.

-Ventingshouldbe checkedoncea yearto assureproperfunctioning.

cleaning of main burner and orifice

(Dlsconnect all powerand gas supply to fhe unit).

1.Removeburnerholddownscrewsand removeburnerand burnerdeflectorshield.

2.Usinga vacuum,cleanbottomof fireboxand orifice.

3.Cleai burnerpartsusingvacuumand anyparticalsthatmaybe lodgedin portsareto be removed usinga smallwireor paperclipEnsure.that all partsare freefromdebris.

4.Re-installburnerand burnerdeflectorand put logsin theirproperlocation.

12

Image 14
Contents Ventedgas Fireplageheater What to do if YOU Smell GASGassupplier For Youb SafetyFor Your Safety 800 Monday to Friday, 9am to 5pm Eastern Standard time Gas train Parts list LloitManual control wlth pressure regulator Techntcalspecficatonseurostvalve\ stove Parts llst Set assembly Mlneral wool placement Door lock screwFan lnstallatlon instructlons ipttonal fan klt #S3rr92l Variablespeed ControlPlease note Installation instructionsGAS Specifications MAY Temperature rangePressure readings Typicalb Ventitstallation Yentlng Instaltailon guldeflnesFlsted vents ExterioruseWarnng Venting installation guldellnesInstallatlon llisted B.OYentl CheckingventcapacityChimneys Venting installation guidelinesInstallation Relining systemsCleaning of main burner and orifice InspectionLighting Tnstruciions Whatto OO if YousmellgasCorrective Action SymptomPossible Cause Posstble Gause CORBECT.IVE AgttonFluegasspillage Causesof Spillageand CorrectiveactionDECORATIUECOLI.ARINSTALLATION