flltrlN I ErrttrNvs
INSTrUGTIONS
1.Periodicvisualchecksofthepilotshouldbeconducted
lo ensurethat the flameis presentexcgptwhenthe valvecontrolknobis in the "OFF" position.-
2.Periodicallyremovethe logsfromthe grateassembly and vacuumany looseparticlesfromthe grateand burnerareas.
GAS CONTROL | TYPICAL FLAME PATTERN SHOWING |
| VIEW OF PILOT FLAME | |
AURNER (A) AND CARRY DOWN POFTS | (B) | FROM ABOVE | ||
|
3.Allcomponentpartsareavailabledirectlythroughthe manufacturerWrite.or phone.
CenturyHeating 330HumberlineDrive,Etobicoke Ontario,Canada,MgW1R5
installationand all repairsshouldbe done by a qualifiedservicepersonThe. applianceshouldbe inspectedbeforeuse and at leastannuallyby a quititiea serviceperson.lt is imperativethat controlcompartments,burnersand
5. Disconnectallpowerto unitbeforeservicing'
WARiltNG: DO NOr ADJUSTTHE GASORIFICEKEEP. .AREACLEARAND FREEFROM COMBUSTIBLEMATERIALS,GASOLINEANDOTHERFLAMMABLEVAPOURSANDLIQUIDS.
inspection
-Pilotand mainburnerflamesshouldbe checkedvisuallyeachmonth.
-Checkand cleanthe mainburneroncea year.
-Ventingshouldbe checkedoncea yearto assureproperfunctioning.
cleaning of main burner and orifice
(Dlsconnect all powerand gas supply to fhe unit).
1.Removeburnerholddownscrewsand removeburnerand burnerdeflectorshield.
2.Usinga vacuum,cleanbottomof fireboxand orifice.
3.Cleai burnerpartsusingvacuumand anyparticalsthatmaybe lodgedin portsareto be removed usinga smallwireor paperclipEnsure.that all partsare freefromdebris.
4.
12