Vermont Casting G400 owner manual Posstble Gause, CORBECT.IVE Agtton

Page 17

-TFOUBLE SHOOTING - G 4 ( ' ( ' -

sYlrPTOm

lll.Frequentpilot outage problem.

lV. Pilotand malnburnergo out white belngin operation.

POSSTBLE GAUSE

A.Pilotflamemaybe too lowor blowing(high),causingthe pitot safetyto dropout.

A.Highlimitswitchisdefectiveor hasreachedit'smaximum temperature.

CORBECT.IVE AGTTON

1.Cleanand adjustpilotflame for maximumflameimpingement on thermocouple.

1.Allowunitto cool.Thenrepeat lightinginstructions.

2.lf 1. abovedoesnot allowfor

ignition,checkhighlimitswitch. Placejumperwiresacrosshigh limitswitch.ll youcan re-ignite the pilot,yourhighlimitswitchis defectiveDo. not use fireplace untilthe highlimitswitchis replaced,as this is an important

safetyfeature.lf the unitdoesnot lightwithjumperwiresin place, the wiresmaybe defectiveor the connectorsare bad.

V.Glasssoots.

....

Vl. Flameburnsblue and lifts otl burner.

B. NO L.P.in tank.

C. Badthermocouple.

A. Flameimpingementon logs.

B.lmproperventurisetting,

C.Minwoolaroundbaseof burneror blockingbottomlront grille.

A.Insufficientoxygenbeing supplied.

1.CheckL.P (Propane)tank. Youmaybe out of fuel.

1.Replaceif necessary.

1.Adjustthe logset so thatthe flamedoesnot impingeon if.

1.Adjustthe airshutteral the baseof the burner.

1.lnspectthe baseol theburner. It is imperativethat NO material be placedaroundthe baseof the burneror in bottomfrontgrilleair passageway,

1.Checkto makesurethatthe minwoolhas not beenimproperly placedat the burnerbaseor blockingbotlomfrontgrille.

1 5

Image 17
Contents What to do if YOU Smell GAS Ventedgas FireplageheaterGassupplier For Youb SafetyFor Your Safety 800 Monday to Friday, 9am to 5pm Eastern Standard time Lloit Gas train Parts listTechntcalspecficatonseurostvalve Manual control wlth pressure regulator\ stove Parts llst Door lock screw Set assembly Mlneral wool placementVariablespeed Control Fan lnstallatlon instructlons ipttonal fan klt #S3rr92lPlease note Installation instructionsGAS Specifications MAY Temperature rangePressure readings Flsted vents Yentlng Instaltailon guldeflnesTypicalb Ventitstallation ExterioruseInstallatlon llisted B.OYentl Venting installation guldellnesWarnng CheckingventcapacityInstallation Venting installation guidelinesChimneys Relining systemsInspection Cleaning of main burner and orificeWhatto OO if Yousmellgas Lighting TnstruciionsCorrective Action SymptomPossible Cause CORBECT.IVE Agtton Posstble GauseCausesof Spillageand Correctiveaction FluegasspillageDECORATIUECOLI.ARINSTALLATION