CIOTHINGOR OTHERFLAMMABLEMATER'AISSHOULDNOTBE PLACEDO'VOR NEARTHEAPPLIANCE.
installation instructions
GAS SPECIFICATIONS
llaturalGas Propane/LP
ManifoldPressure 3.5"W.C. 10.0"w.c.
MinimumInletPressure' 5.0"w.c. 11.0"WC.
MaximumlnletPressure 10.5"W.C. 13.0"W.C.
Fl'UInputRating(Max.) 30,000 26,000
BTUInputRating(Min.) 23,500 23,500
'For
purposeot lnput Mustment.
2 . Makegas connectionto the valveassemblywith:
l)Blackironpipeor malleableironfittingsor . . .
ll)A corrugatedmetalconnector(notto exceed2 feet in length)or . . .
lll)Copperpipeor tubing(internallytinned)if accep- tableto the authorityhavingjurisdiction.
Turngassupplyon andcheckforleaks.DONOf USE OPENFLAME.Usesoapandwatersolution.
Forcorrectpositioningof logsonthegrate,referto SET ASSEMBLY.
lnstallationand provisionforcombustionandventila- tionair mustconlormwith localcodeso[ in absence of localcodes,withtheNationalFuelGasCode,ANSI Z,223l- latestedition- in the UnitedStatesor, in
Canada,withthe- currentCAN/CGABl49.lnstallation
Code.
Keepoperatingareaclearandfreelromcombustible materials,gasoline,and otherllammableliquidsand vapours.
Theapplianceanditsindividualshutoffvalvemustbe disconnectedfromthegassupplypipingsystemduring anypressuretestingof thesystemattestpressuresin excessof 1/2psig(3.5kPa.)
8.Theappliancemuslbeisolatedfromthegassupplypip ingby closingitsindividualmanualshutotfvalvedur- inganypressuretestingofthegassupplypipingsystom attestpressureequaltoor lessthan112psig(35kPa.).
9.A
A gasappliancemustnotbe connectedto a chimney llue servinga soparatesolidfuel burningappliance.
DUETO HIGHTEMPERATURES,THEAPPLIANCE SHOULDBE LOCATEDOUT OF TRAFFICAND AWAYFROMFURNITUREANDDBAPERIES.
The appliance,wheninstalledmustbe electrically connectedand groundedin accordancewith local codesor,in the absenceof localcodes,with the currentC9{
CH'LDRENAND ADULTSSHOUTDBE ALERTEDTO THE HATARDSOF HIGHSURFACE TEMPENNUREANDSHOUTDSTAYAWAYTO AVOIDBUR'VSOR CI.OTHING'G'V'T'O'V.
CLEARANCETO COMBUSTIBLES
CeilingHeight | Minimum= 24" | |
Sides | Minimum= | 8" |
Front | Minimum= 36" | |
Backof Stove | Minimum= | 9" |
DO NOTUSElfits heater lf any paft has been under water.lmmedlatelycall a qualtfledserylce technlclan to inspect lhe fieater and to replace any part of the control system and any gas control whlch has been under waten
please note
It is normalforyour CenturyHeatingfireplaceto giveotf someodourthe first tlmeit is burned. Thisis dueto the curingof the paintandanyundetectedoll fromthe manufacturingprocess.
Pleaseensure your- open
that roomis wellventllatqd atlwindows.
IT IS IMPEBATIVETHATTHECONTROLCOMPARITUENTBURNER,ANDCTRCULATINGAIB PASSAGEWAYS BE KEPTCLEANANDCLEAR.PROVTDEFORADEOUATECOMBUSTIONANDVENTILATIONAIR. PROVIDE ADEOI'ATECLEARANCESAROUNDAIR OPENINGSAND ADEOUATEACCESSIBILITYCLEARANCEFOR SERI/ICEANDPROPEROPERATTONNEVER.OBSTRUCTTHEFRONTOPENINGOFTHEAPPLTANCEORTHE DIRECTVENTTERi'INATIONON THEEXTERIOROF THE BUILDING.
7