Vermont Casting 2996, 2950 Venting System Assembly Direct Vent General Information, Rear Vent

Page 16

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

ST241

Cut pad to size and locate as needed

FK105

Fig. 21 Vibration dampening pad location.

Fig. 19 Correct position of fan skirt installation.

4. The rheostat control switch attaches to the left side of

the valve bracket at the front of the stove. (Fig. 20)

MOTOR

Blower Wiring Diagram

Fan Assembly

No. 000-2960 / FK28

Remove the plug from the rheostat bracket.

Insert the switch box shaft through the hole in the

back of the right side of the valve bracket, aligning

the locator pin with the smaller hole in that bracket.

Attach the retaining nut to the switch control shaft

to secure it to the plate.

Attach the Control Knob to the rheostat shaft.

Use the wire tie to secure the fan and rheostat

wire harnesses together.

Retaining Nut

Rheostat Knob

Rheostat

FK104

Fig. 20 Attach rheostat to bracket.

5.A length of silicone tape is included for installation between the Top Plate and the Rear Shroud, should you find that contact between these two surfaces causes vibration while the fan is operating.

Remove the Top Plate.

Cut the self-adhesive tape to size as needed, remove the backing paper and place tape on the top edge of the Shroud at those locations where it will eliminate direct contact between the Shroud and the Top Plate. (Fig. 21)

Replace the Top Plate.

BLK

 

BLK

BLK

 

 

 

 

 

 

SNAPSTAT

 

 

BLK

WHT

WHT

GRN

ON/OFF

 

RHEOSTAT

WARNING:

 

 

 

DISCONNECT

 

 

 

ELECTRICAL SUPPLY

 

 

 

BEFORE SERVICING

Fig. 22 Blower wiring diagram.

 

Venting System Assembly -

Direct Vent

General Information

The PDV20 and SDVR are approved for installation only with the vent components listed on page 13. Follow the vent component instructions exactly. These instructions apply to both the PDV20 and the SDVR shell.

For U.S. installations: The venting system must conform with local codes and/or the current National Fuel Gas Code, ANSI Z223.1

For Canadian installations: The venting system must conform to the current CSA B149.1 installation code.

Rear Vent

Use Rear Vent Kit 7TFSRSK for an installation where the heater is parallel to the wall and the vent system extends straight back through that wall.

1.Attach Inner Starter Pipe, (found in with the logset), to the stove.

Run a bead of sealant beneath the pipe bead and

attach to the stove using three 1/4-20 x 3/8” phillips screws provided in the parts bag. (Fig. 23)

16

20003457

Image 16
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Pinnacle Direct Vent Gas Heater Stove Dimensions Stardance Direct Vent Gas HeaterClearance Requirements Minimum Clearances to Combustible MaterialsGas Specifications Mantel Clearances Hearth RequirementsGas Inlet and Manifold Pressures Input Model Fuel Gas Control BTU/hHigh Elevations Horizontal TerminationVertical Termination Vent Termination ClearancesLocation of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationTermination Clearances Vent Components Assembly Procedures Parts Bag ContentsTool/Materials Required Firebox PreparationHeater Shell Assembly Fasten the left side to the rear shroudInstall Optional Fan Kit #2960/FK28 Install the FireboxFan Kit Contents Venting System Assembly Direct Vent General Information Rear VentThrough Side Wall Vent Termination Below Grade Vent Opening -Noncombustible WallInstall inner starter pipe and inner elbow Side Wall Termination Assembly Vent Opening Noncombustible Wall400mm below the base of the snorkel. Install a Vertical Through the Roof Vent Assembly ³⁄₈ x 9³⁄₈ 240mm x 240mmVertical Through Existing Chimney Fireplace Vent Termination ClearancesFireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Complete the Assembly Install ON/OFF Switch R Models onlyConnect the Gas Supply Line Burner InformationInstall the Front and Top Plates This completes assembly of the PDV20 and Sdvr stoveThermostat Connection Use only a thermostat rated for 500 750 millivoltsInstall the Log Set LogsModels 2995, 2996, 2997 Models 2950Flame & Temperature Adjustment Flame CharacteristicsOperation Your First FireCorrect pilot flame pattern. PSE Pilot To Turn Off Gas To Heater Lighting And Operating InstructionsWhat to do if YOU Smell GAS Troubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionShut Off Procedure Transmitter Operation Off ModeOn Manual Mode Delay Timer ModeAuto Mode Fan Override During Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Conversion Precautions Conversion ProcedureAuto Path Fuel Conversion InstructionsModels 2995, 2996 R Models Only Pilot TypeModels 2997, 2998 RF Models Only All ModelsConversion to Natural Gas Input BTU/h Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Stove Disassembly Wiring Diagrams5a,b6 Description 2950 PDV20 SdvrFuel Conversion Kits Shell Enamel Part Numbers PDV20 ColorLeft End Right End Front Control Door Shell Enamel Part Numbers Sdvr ColorOptional Accessories Remote ControlsFan Kits Screen KitProduct Covered by this Warranty If Warranty Service is NEEDED…Vermont Castings, Majestic Products

2950, 2995, 2998, 2996, 2997 specifications

Vermont Castings is renowned for its high-quality cast iron stoves and fireplaces, and the models 2996, 2951, 2950, 2998, and 2997 exemplify this legacy. These stoves are designed to provide both efficiency and aesthetic appeal, making them ideal choices for any home.

Starting with the Vermont Casting 2996, this model is a highly efficient wood-burning stove known for its impressive heat output. It features a robust cast iron construction that not only enhances durability but also retains heat effectively, ensuring a long-lasting warmth. The 2996 boasts an advanced air wash system, keeping the glass door clean for a clear view of the flames while promoting optimal burn efficiency.

The Vermont Casting 2951 is another standout model, recognized for its compact size without sacrificing performance. This stove is designed for smaller spaces and is equipped with an innovative catalytic combustor that maximizes fuel efficiency and minimizes emissions. Its elegant design includes a variety of color options, allowing homeowners to select a finish that complements their interiors perfectly.

Moving on to the Vermont Casting 2950, this model offers a blend of tradition and modern technology. It utilizes a secondary combustion system that captures and re-burns gases released during the burning process. This leads to cleaner combustion and increased energy output. The 2950's detailed cast iron craftsmanship not only provides classic appeal but also ensures longevity.

The 2998 model stands out with its large firebox capacity, making it suitable for extended burn times. Designed for wood logs up to 20 inches, it offers an efficient heat output, making it ideal for colder climates. The stove features an easy-to-use air control that allows users to adjust the burn rate for their heating needs, promoting both efficiency and comfort.

Lastly, the Vermont Casting 2997 brings a unique blend of style and functionality. Its distinctive design includes an optional soapstone top, enhancing heat retention and providing an elegant aesthetic. With built-in features like the easy-access ash pan, homeowners can enjoy a hassle-free experience while maintaining their stove.

Overall, these Vermont Castings models showcase advanced heating technologies combined with beautiful design. Their commitment to efficiency, durability, and aesthetics makes them a popular choice for those seeking a reliable heating solution. Whether it's for the cozy ambiance or efficient warmth, Vermont Castings continues to set a standard in the wood stove industry.