Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Auto Mode

In the AUTO mode, the room temperature, set tempera- ture, flame and fan levels will be shown. AUTO will appear next to both the flame and fan icons.

When the control is in the AUTO mode, the main burner will turn on/off or modulate based on the heat needed to maintain the set temperature. The flame level will change automatically to optimize the heat output needed to maintain the set temperature. To change the set temperature, press the up or down key. Pushing a key once will change the temperature by one degree.

In the AUTO mode, the fan speed will increase with increasing flame height or decrease with decreasing flame height. “AUTO” is displayed next to the flame and fan icons.

Fan Override During Auto Mode

If a lower or higher fan speed is desired when operating in the AUTO mode, the fan speed can be overridden by pushing the fan button followed by the up or down key.

Pushing a key once will change the fan level by one unit. In this mode “AUTO” is displayed next to the flame icon and “MANUAL” is displayed next to the fan icon.

Change Between F/C Temperature Units

Push the up and down arrow keys simultaneously for at least 3 seconds to toggle between Fahrenheit and Celsius units.

Disable Thermostat Function

To disable the thermostat function in the AUTO mode, push the time and down keys simultaneously for at least 3 seconds.

To Change Batteries

1.Remove cover on the backside of the transmitter. Install 3 AAA batteries as shown and reattach cover.

2.Once steps 1-3 in OPERATION are completed, receiver/valve and transmitter are now ready. Press any button on transmitter for recognition process to occur between the receiver/valve and transmitter.

3.Use functions as described in TRANSMITTER section.

Troubleshooting

1.Locate LED light on valve.

2.LED will blink after every valid command received by the transmitter; this is not an error.

3.Failure codes may occur anytime after pilot burner is lit.

4.Sequence is failure code followed by light not blinking for 30 seconds.

5.In the event of multiple failure codes, next failure code follows previous failure code by approximately 3 seconds.

 

Pilot

 

Assembly

 

Fan

 

FAN

 

Red

 

White

 

Red

 

White

 

White Dots

 

Antenna

 

Valve

FP1038

(Bottom View)

 

Fig. 67

Comfort Valve wiring diagram.

If an Error Code 3 is observed while performing the testing, complete the following:

1.Make sure the spade connectors are pushed all the way on. If rhe Error Code 3 is still showing, then go to the next step.

2.Switch the front two thermopile leads with the back two. Be sure the white lead is connected to the spade with the white dot next to it. If the Error Code 3 is still showing, replace the thermopiles.

If an Error Code 8 is observed while performing the testing, complete the following:

1.Confirm the valve is not in REMOTE mode.

If the valve is producing Error Code 8 and in REMOTE mode, the valve is defective and should be replaced.

If the valve is in LOCAL mode and producing Error Code 8, then go to the next step.

2.Slide the Remote/Local switch to REMOTE and teach the valve a transmitter (see item 6, page 1). The Error Code will clear itself after approximately 1.5 minutes and return to normal operation.

LED Count

Service Action

8 Replace valve

7Confirm stepper motor connection exists

5Confirm fan connection exists and works

4Confirm gas type; jumper in place

3Replace thermopiles

2Turn fan ON

NOTE: Some keys are not active.

20003457

33

Image 33
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Stardance Direct Vent Gas Heater Stove Dimensions Pinnacle Direct Vent Gas HeaterMinimum Clearances to Combustible Materials Clearance RequirementsMantel Clearances Hearth Requirements Gas SpecificationsGas Inlet and Manifold Pressures Input Model Fuel Gas Control BTU/hHorizontal Termination High ElevationsVent Termination Clearances Vertical TerminationLocation of Vent Termination General Venting Information Termination Location Canadian Installations US InstallationsTermination Clearances Vent Components Parts Bag Contents Assembly ProceduresTool/Materials Required Firebox PreparationFasten the left side to the rear shroud Heater Shell AssemblyInstall the Firebox Install Optional Fan Kit #2960/FK28Fan Kit Contents Rear Vent Venting System Assembly Direct Vent General InformationVent Opening -Noncombustible Wall Through Side Wall Vent Termination Below GradeInstall inner starter pipe and inner elbow Vent Opening Noncombustible Wall Side Wall Termination Assembly400mm below the base of the snorkel. Install a ³⁄₈ x 9³⁄₈ 240mm x 240mm Vertical Through the Roof Vent AssemblyFireplace Vent Termination Clearances Vertical Through Existing ChimneyFireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Install ON/OFF Switch R Models only Complete the AssemblyConnect the Gas Supply Line Burner InformationThis completes assembly of the PDV20 and Sdvr stove Install the Front and Top PlatesThermostat Connection Use only a thermostat rated for 500 750 millivoltsLogs Install the Log SetModels 2995, 2996, 2997 Models 2950Flame Characteristics Flame & Temperature AdjustmentOperation Your First FireCorrect pilot flame pattern. PSE Pilot Lighting And Operating Instructions To Turn Off Gas To HeaterWhat to do if YOU Smell GAS Symptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemTransmitter Operation Off Mode Shut Off ProcedureOn Manual Mode Delay Timer ModeFan Override During Auto Mode Auto ModeChange Between F/C Temperature Units Disable Thermostat FunctionLocal Path Conversion Procedure Conversion PrecautionsAuto Path Fuel Conversion InstructionsPilot Type Models 2995, 2996 R Models OnlyAll Models Models 2997, 2998 RF Models OnlyConversion to Natural Gas Input BTU/h Conversion to LP Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Wiring Diagrams Stove Disassembly5a,b6 PDV20 Sdvr Description 2950Shell Enamel Part Numbers PDV20 Color Fuel Conversion KitsLeft End Right End Front Control Door Shell Enamel Part Numbers Sdvr ColorRemote Controls Optional AccessoriesFan Kits Screen KitIf Warranty Service is NEEDED… Product Covered by this WarrantyVermont Castings, Majestic Products

2950, 2995, 2998, 2996, 2997 specifications

Vermont Castings is renowned for its high-quality cast iron stoves and fireplaces, and the models 2996, 2951, 2950, 2998, and 2997 exemplify this legacy. These stoves are designed to provide both efficiency and aesthetic appeal, making them ideal choices for any home.

Starting with the Vermont Casting 2996, this model is a highly efficient wood-burning stove known for its impressive heat output. It features a robust cast iron construction that not only enhances durability but also retains heat effectively, ensuring a long-lasting warmth. The 2996 boasts an advanced air wash system, keeping the glass door clean for a clear view of the flames while promoting optimal burn efficiency.

The Vermont Casting 2951 is another standout model, recognized for its compact size without sacrificing performance. This stove is designed for smaller spaces and is equipped with an innovative catalytic combustor that maximizes fuel efficiency and minimizes emissions. Its elegant design includes a variety of color options, allowing homeowners to select a finish that complements their interiors perfectly.

Moving on to the Vermont Casting 2950, this model offers a blend of tradition and modern technology. It utilizes a secondary combustion system that captures and re-burns gases released during the burning process. This leads to cleaner combustion and increased energy output. The 2950's detailed cast iron craftsmanship not only provides classic appeal but also ensures longevity.

The 2998 model stands out with its large firebox capacity, making it suitable for extended burn times. Designed for wood logs up to 20 inches, it offers an efficient heat output, making it ideal for colder climates. The stove features an easy-to-use air control that allows users to adjust the burn rate for their heating needs, promoting both efficiency and comfort.

Lastly, the Vermont Casting 2997 brings a unique blend of style and functionality. Its distinctive design includes an optional soapstone top, enhancing heat retention and providing an elegant aesthetic. With built-in features like the easy-access ash pan, homeowners can enjoy a hassle-free experience while maintaining their stove.

Overall, these Vermont Castings models showcase advanced heating technologies combined with beautiful design. Their commitment to efficiency, durability, and aesthetics makes them a popular choice for those seeking a reliable heating solution. Whether it's for the cozy ambiance or efficient warmth, Vermont Castings continues to set a standard in the wood stove industry.