Vermont Casting 2950, 2951, 2998 Lighting And Operating Instructions, To Turn Off Gas To Heater

Page 30

Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Lighting And Operating Instructions

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

A.This heater has a pilot which must be lit manually. When lighting the pilot follow these instructions exactly.

B.BEFORE LIGHTING smell all around the heater area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.

If you cannot reach your gas supplier, call the Fire Department

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Applying force or any attempted repair may result in a fire or explosion.

D.Do not use this fireplace if any part has been under water. Immediately call a qualified service techni- cian to inspect the heater and to replace any part of the control system and any gas control which has been under water.

Lighting Instructions

1.STOP! Read the safety information above.

2.Turn off all electrical power to the fireplace.

3.For MN/MP/TN/TP appliances ONLY, go on to Step 4. For RN/RP appliances turn the On/Off switch to “OFF” position or set thermostat to lowest level.

4.Open control access panel.

5.Push in gas control knob slightly and turn

clockwise to "OFF".

 

 

 

 

PILOT

OFF

 

 

 

 

PILOT

 

 

1

 

 

t

 

F

 

 

 

 

 

 

o

 

 

ON

ON

P

 

 

F

 

 

F

l

 

 

 

 

 

i

 

2

 

 

 

O

 

O

 

 

F

 

 

 

 

 

5

 

3

 

FFO

 

4

 

 

 

 

 

 

 

 

Euro SIT

SIT NOVA

Honeywell

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you do not smell gas, go to the next step.

7.Remove glass door before lighting pilot. (See Glass Frame Removal section).

8.Visibly locate pilot by the main burner.

9.Turn knob on gas control counterclockwise

to "PILOT".

10.Push the control knob all the way in and hold. Immediately light the pilot by repeatedly depressing the piezo spark ignitor until a flame appears. Continue to hold the control knob in for about one (1) minute after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

3/8" - 1/2"

If knob does not pop up when released, stop and immediately call your service technician or gas supplier.

If after several tries, the pilot will not stay lit, turn the gas control knob to "OFF" and call your service technician or gas supplier.

11.Replace glass door.

12.Turn gas control knob to “ON” position.

13.For RN/RP appliances turn the On/Off switch to “ON” position or set thermostat to desired setting.

14.Turn on all electrical power to the fireplace.

To Turn Off Gas To Heater

1.

Turn the On/Off switch to Off position or set the

3.

Open control access panel.

 

thermostat to lowest setting.

4.

Push in gas control knob slightly and turn

2.

Turn off all electric power to the fireplace if

 

clockwise

to "OFF". Do not force.

 

service is to be performed.

5.

Close control access panel.

30

20003457

Image 30
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Pinnacle Direct Vent Gas Heater Stove Dimensions Stardance Direct Vent Gas HeaterClearance Requirements Minimum Clearances to Combustible MaterialsGas Inlet and Manifold Pressures Gas SpecificationsMantel Clearances Hearth Requirements Input Model Fuel Gas Control BTU/hHigh Elevations Horizontal TerminationVertical Termination Vent Termination ClearancesLocation of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationTermination Clearances Vent Components Tool/Materials Required Assembly ProceduresParts Bag Contents Firebox PreparationHeater Shell Assembly Fasten the left side to the rear shroudInstall the Firebox Install Optional Fan Kit #2960/FK28Fan Kit Contents Venting System Assembly Direct Vent General Information Rear VentThrough Side Wall Vent Termination Below Grade Vent Opening -Noncombustible WallInstall inner starter pipe and inner elbow Side Wall Termination Assembly Vent Opening Noncombustible Wall400mm below the base of the snorkel. Install a Vertical Through the Roof Vent Assembly ³⁄₈ x 9³⁄₈ 240mm x 240mmVertical Through Existing Chimney Fireplace Vent Termination ClearancesFireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Connect the Gas Supply Line Complete the AssemblyInstall ON/OFF Switch R Models only Burner InformationThermostat Connection Install the Front and Top PlatesThis completes assembly of the PDV20 and Sdvr stove Use only a thermostat rated for 500 750 millivoltsModels 2995, 2996, 2997 Install the Log SetLogs Models 2950Operation Flame & Temperature AdjustmentFlame Characteristics Your First FireCorrect pilot flame pattern. PSE Pilot Lighting And Operating Instructions To Turn Off Gas To HeaterWhat to do if YOU Smell GAS Troubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path Auto Path Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsModels 2995, 2996 R Models Only Pilot TypeConversion to Natural Gas Input BTU/h Models 2997, 2998 RF Models OnlyAll Models Conversion to LP Input BTU/hMaintenance Gasket Replacement Inspect the Vent System AnnuallyCheck the Gas Flame Regularly Stove Disassembly Wiring Diagrams5a,b6 Description 2950 PDV20 SdvrLeft End Right End Front Control Door Fuel Conversion KitsShell Enamel Part Numbers PDV20 Color Shell Enamel Part Numbers Sdvr ColorFan Kits Optional AccessoriesRemote Controls Screen KitProduct Covered by this Warranty If Warranty Service is NEEDED…Vermont Castings, Majestic Products

2950, 2995, 2998, 2996, 2997 specifications

Vermont Castings is renowned for its high-quality cast iron stoves and fireplaces, and the models 2996, 2951, 2950, 2998, and 2997 exemplify this legacy. These stoves are designed to provide both efficiency and aesthetic appeal, making them ideal choices for any home.

Starting with the Vermont Casting 2996, this model is a highly efficient wood-burning stove known for its impressive heat output. It features a robust cast iron construction that not only enhances durability but also retains heat effectively, ensuring a long-lasting warmth. The 2996 boasts an advanced air wash system, keeping the glass door clean for a clear view of the flames while promoting optimal burn efficiency.

The Vermont Casting 2951 is another standout model, recognized for its compact size without sacrificing performance. This stove is designed for smaller spaces and is equipped with an innovative catalytic combustor that maximizes fuel efficiency and minimizes emissions. Its elegant design includes a variety of color options, allowing homeowners to select a finish that complements their interiors perfectly.

Moving on to the Vermont Casting 2950, this model offers a blend of tradition and modern technology. It utilizes a secondary combustion system that captures and re-burns gases released during the burning process. This leads to cleaner combustion and increased energy output. The 2950's detailed cast iron craftsmanship not only provides classic appeal but also ensures longevity.

The 2998 model stands out with its large firebox capacity, making it suitable for extended burn times. Designed for wood logs up to 20 inches, it offers an efficient heat output, making it ideal for colder climates. The stove features an easy-to-use air control that allows users to adjust the burn rate for their heating needs, promoting both efficiency and comfort.

Lastly, the Vermont Casting 2997 brings a unique blend of style and functionality. Its distinctive design includes an optional soapstone top, enhancing heat retention and providing an elegant aesthetic. With built-in features like the easy-access ash pan, homeowners can enjoy a hassle-free experience while maintaining their stove.

Overall, these Vermont Castings models showcase advanced heating technologies combined with beautiful design. Their commitment to efficiency, durability, and aesthetics makes them a popular choice for those seeking a reliable heating solution. Whether it's for the cozy ambiance or efficient warmth, Vermont Castings continues to set a standard in the wood stove industry.