Vermont Castings Pinnacle & Stardance Direct Vent - Rear Vent Gas Heaters

Pinnacle / Stardance

Direct Vent / Rear Vent

Certified to:

ANSI Z21.88b-2001 / CSA Z2.33b-2001

Vented Gas Fireplace Heaters

The installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 - latest edition. (EXCEPTION: Do not derate this appliance for altitude. Maintain the manifold pressure at 3.5” w.c. for Natural Gas and 10” w.c. for Propane.)

High Elevations

Input ratings are shown in BTU per hour and are certified without deration for elevations up to 4,500 feet (1,370m) above sea level.

For elevations above 4,500 feet (1,370m) in USA, installations must be in accordance with the current ANSI Z223.1 and/or local codes having jurisdiction.

In Canada, please consult provincial and/or local authorities having jurisdiction for installations at elevations above 4,500 feet (1,370m).

WARNING: Improper installation, adjust- ment, alteration, service or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

Horizontal Termination

The vent must rise vertically a minimum of 24” (610mm) after the first elbow directly off the back of the unit, before the next elbow. The horizontal run may extend up to 20’ (6m) and include a vertical rise of up to 40’ (12m). (Fig. 7) Horizontal termination must also meet the criteria shown in Figures 9 and 10.

Approved vent systems must terminate above and including the heavy line in Figure 7.

Two 45° elbows may be substituted for each single 90˚ elbow.

With a rise between 2' - 5', one 90° or two 45° elbows may be used (Excluding the first elbow directly off the back of the unit.

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

Venting Configuration

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

elbow)

23

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Measured after the first elbow. (Transition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Vertical Run (in feet)

20

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

15

 

May use up to

 

 

 

 

 

 

 

 

 

 

 

 

 

14

 

three 90° Elbows

 

 

 

 

 

 

 

 

 

 

 

 

 

(Excluding elbow

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

 

 

directly off back

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

of unit.)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

One 90°

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Elbow*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

Unacceptable

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

Venting Configuration

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

Horizontal Run (in feet)

ST134f

Fig. 7 Horizontal vent termination window.

* Not the transition elbow.

20003457

7

Image 7
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Stardance Direct Vent Gas Heater Stove Dimensions Pinnacle Direct Vent Gas HeaterMinimum Clearances to Combustible Materials Clearance RequirementsInput Model Fuel Gas Control BTU/h Gas SpecificationsMantel Clearances Hearth Requirements Gas Inlet and Manifold PressuresHorizontal Termination High ElevationsVent Termination Clearances Vertical TerminationLocation of Vent Termination General Venting Information Termination Location Canadian Installations US InstallationsTermination Clearances Vent Components Firebox Preparation Assembly ProceduresParts Bag Contents Tool/Materials RequiredFasten the left side to the rear shroud Heater Shell AssemblyInstall Optional Fan Kit #2960/FK28 Install the FireboxFan Kit Contents Rear Vent Venting System Assembly Direct Vent General InformationVent Opening -Noncombustible Wall Through Side Wall Vent Termination Below GradeInstall inner starter pipe and inner elbow Vent Opening Noncombustible Wall Side Wall Termination Assembly400mm below the base of the snorkel. Install a ³⁄₈ x 9³⁄₈ 240mm x 240mm Vertical Through the Roof Vent AssemblyFireplace Vent Termination Clearances Vertical Through Existing ChimneyFireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Burner Information Complete the AssemblyInstall ON/OFF Switch R Models only Connect the Gas Supply LineUse only a thermostat rated for 500 750 millivolts Install the Front and Top PlatesThis completes assembly of the PDV20 and Sdvr stove Thermostat ConnectionModels 2950 Install the Log SetLogs Models 2995, 2996, 2997Your First Fire Flame & Temperature AdjustmentFlame Characteristics OperationCorrect pilot flame pattern. PSE Pilot To Turn Off Gas To Heater Lighting And Operating InstructionsWhat to do if YOU Smell GAS Symptom Possible Causes Corrective Action Troubleshooting / Honeywell #8420 Gas Control SystemDelay Timer Mode Shut Off ProcedureTransmitter Operation Off Mode On Manual ModeDisable Thermostat Function Auto ModeFan Override During Auto Mode Change Between F/C Temperature UnitsLocal Path Fuel Conversion Instructions Conversion PrecautionsConversion Procedure Auto PathPilot Type Models 2995, 2996 R Models OnlyConversion to LP Input BTU/h Models 2997, 2998 RF Models OnlyAll Models Conversion to Natural Gas Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Wiring Diagrams Stove Disassembly5a,b6 PDV20 Sdvr Description 2950Shell Enamel Part Numbers Sdvr Color Fuel Conversion KitsShell Enamel Part Numbers PDV20 Color Left End Right End Front Control DoorScreen Kit Optional AccessoriesRemote Controls Fan KitsIf Warranty Service is NEEDED… Product Covered by this WarrantyVermont Castings, Majestic Products

2950, 2995, 2998, 2996, 2997 specifications

Vermont Castings is renowned for its high-quality cast iron stoves and fireplaces, and the models 2996, 2951, 2950, 2998, and 2997 exemplify this legacy. These stoves are designed to provide both efficiency and aesthetic appeal, making them ideal choices for any home.

Starting with the Vermont Casting 2996, this model is a highly efficient wood-burning stove known for its impressive heat output. It features a robust cast iron construction that not only enhances durability but also retains heat effectively, ensuring a long-lasting warmth. The 2996 boasts an advanced air wash system, keeping the glass door clean for a clear view of the flames while promoting optimal burn efficiency.

The Vermont Casting 2951 is another standout model, recognized for its compact size without sacrificing performance. This stove is designed for smaller spaces and is equipped with an innovative catalytic combustor that maximizes fuel efficiency and minimizes emissions. Its elegant design includes a variety of color options, allowing homeowners to select a finish that complements their interiors perfectly.

Moving on to the Vermont Casting 2950, this model offers a blend of tradition and modern technology. It utilizes a secondary combustion system that captures and re-burns gases released during the burning process. This leads to cleaner combustion and increased energy output. The 2950's detailed cast iron craftsmanship not only provides classic appeal but also ensures longevity.

The 2998 model stands out with its large firebox capacity, making it suitable for extended burn times. Designed for wood logs up to 20 inches, it offers an efficient heat output, making it ideal for colder climates. The stove features an easy-to-use air control that allows users to adjust the burn rate for their heating needs, promoting both efficiency and comfort.

Lastly, the Vermont Casting 2997 brings a unique blend of style and functionality. Its distinctive design includes an optional soapstone top, enhancing heat retention and providing an elegant aesthetic. With built-in features like the easy-access ash pan, homeowners can enjoy a hassle-free experience while maintaining their stove.

Overall, these Vermont Castings models showcase advanced heating technologies combined with beautiful design. Their commitment to efficiency, durability, and aesthetics makes them a popular choice for those seeking a reliable heating solution. Whether it's for the cozy ambiance or efficient warmth, Vermont Castings continues to set a standard in the wood stove industry.