Vertical Through Existing Chimney

The heater must be vented to the outdoors through an existing masonry or prefabricated fireplace chimney system through the roof.

The heater is approved to be vented to the outdoors through any solid-fuel fireplace chimney that has been constructed or installed in accordance with the na- tional, Provincial/State and local building codes and is constructed of noncombustible materials. For Venting Requirements, refer to page 9. Refer to Venting Components on page 13.

Fireplace Vent Termination Clearances

Observe the chimney-top vent termination clearances specified in the instructions provided with those components. Some considerations are:

Obstructions or impediments to venting.

Nearby combustible materials that could come into contact with combustion exhaust gases.

Other nearby openings (within 9” (230mm) through which exhaust gas could reenter the building.

All vegetation within 3 feet (9m) that may interfere with the draft.

Note: The collar extending down from the Termination base is the air intake collar. Use the flex vent liner, marked with a blue line, to connect between this collar and the lower flue collar on the Transition Connector. Also make sure the other flex vent liner is attached to the upper Transition Connector collar and the Rain Cap. (Fig. 42)

1.Clean the top of the chimney as needed, to ensure a good seal between it and the vent termination.

2.Slide the insulation sleeves provided in the termina- tion kit over the two 3" flex liners (to be attached to the 3" flue collar and cap of the termination assem- bly).

3.Feed 3" flex vent from the bottom of the termination assembly up through the 4" sleeve. Apply high- temperature sealant to the rain cap collar, and slide the flex vent over the end of the rain cap collar, fastening with the clamp provided.

4.Slide the flex liner back through the 4" sleeve until the rain cap/collar engages over the sleeve. Attach the cap to the sleeve with three sheet metal screws provided in the kit.

5.Apply high-temperature sealant over the air intake collar, and attach the intake flex vent (blue) with a clamp.

6.Apply high-temperature sealant to the top of the chimney. Feed the two liners down through the chimney flue and damper opening. Fasten the termination assembly to the chimney with the four set screws (C) provided.

7.Trim the flex liners as needed. Each should be only long enough to connect to the Transition Connector. There should be no sag in either flex liner when the stove is in place.

8.Attach the flex liners to the Transition Connector, using high-temperature sealant and clamps as shown in Figure 41. Prop the connector in rough position until the heater is in place in front of it.

Fireplace Vent System

 

 

B

 

 

 

 

 

B

 

 

 

A

B

 

 

D

 

 

 

B

C

 

 

C

 

 

 

B

 

 

C

A = Sealant Locations

 

 

A

 

 

B = Sheet Metal Screws

 

B

 

 

C = Termination Screws

D

 

A

D = Clamps

 

 

 

A

 

B

A

D

 

 

A

 

D

B

ST395

Fig. 42 Fireplace vent system installation.

22

20003457

Image 22
Contents Pinnacle & Stardance Direct Vent, Rear Vent Gas Heater Table of Contents Installation & Operating Instructions Stove Dimensions Pinnacle Direct Vent Gas Heater Stove Dimensions Stardance Direct Vent Gas HeaterClearance Requirements Minimum Clearances to Combustible MaterialsGas Inlet and Manifold Pressures Gas SpecificationsMantel Clearances Hearth Requirements Input Model Fuel Gas Control BTU/hHigh Elevations Horizontal TerminationVertical Termination Vent Termination ClearancesLocation of Vent Termination Canadian Installations US Installations General Venting Information Termination LocationTermination Clearances Vent Components Tool/Materials Required Assembly ProceduresParts Bag Contents Firebox PreparationHeater Shell Assembly Fasten the left side to the rear shroudInstall Optional Fan Kit #2960/FK28 Install the FireboxFan Kit Contents Venting System Assembly Direct Vent General Information Rear VentThrough Side Wall Vent Termination Below Grade Vent Opening -Noncombustible WallInstall inner starter pipe and inner elbow Side Wall Termination Assembly Vent Opening Noncombustible Wall400mm below the base of the snorkel. Install a Vertical Through the Roof Vent Assembly ³⁄₈ x 9³⁄₈ 240mm x 240mmVertical Through Existing Chimney Fireplace Vent Termination ClearancesFireplace Installation Requirements PDV20 Fireplace Installation Requirements Sdvr Connect the Gas Supply Line Complete the AssemblyInstall ON/OFF Switch R Models only Burner InformationThermostat Connection Install the Front and Top PlatesThis completes assembly of the PDV20 and Sdvr stove Use only a thermostat rated for 500 750 millivoltsModels 2995, 2996, 2997 Install the Log SetLogs Models 2950Operation Flame & Temperature AdjustmentFlame Characteristics Your First FireCorrect pilot flame pattern. PSE Pilot To Turn Off Gas To Heater Lighting And Operating InstructionsWhat to do if YOU Smell GAS Troubleshooting / Honeywell #8420 Gas Control System Symptom Possible Causes Corrective ActionOn Manual Mode Shut Off ProcedureTransmitter Operation Off Mode Delay Timer ModeChange Between F/C Temperature Units Auto ModeFan Override During Auto Mode Disable Thermostat FunctionLocal Path Auto Path Conversion PrecautionsConversion Procedure Fuel Conversion InstructionsModels 2995, 2996 R Models Only Pilot TypeConversion to Natural Gas Input BTU/h Models 2997, 2998 RF Models OnlyAll Models Conversion to LP Input BTU/hMaintenance Inspect the Vent System Annually Gasket ReplacementCheck the Gas Flame Regularly Stove Disassembly Wiring Diagrams5a,b6 Description 2950 PDV20 SdvrLeft End Right End Front Control Door Fuel Conversion KitsShell Enamel Part Numbers PDV20 Color Shell Enamel Part Numbers Sdvr ColorFan Kits Optional AccessoriesRemote Controls Screen KitProduct Covered by this Warranty If Warranty Service is NEEDED…Vermont Castings, Majestic Products

2950, 2995, 2998, 2996, 2997 specifications

Vermont Castings is renowned for its high-quality cast iron stoves and fireplaces, and the models 2996, 2951, 2950, 2998, and 2997 exemplify this legacy. These stoves are designed to provide both efficiency and aesthetic appeal, making them ideal choices for any home.

Starting with the Vermont Casting 2996, this model is a highly efficient wood-burning stove known for its impressive heat output. It features a robust cast iron construction that not only enhances durability but also retains heat effectively, ensuring a long-lasting warmth. The 2996 boasts an advanced air wash system, keeping the glass door clean for a clear view of the flames while promoting optimal burn efficiency.

The Vermont Casting 2951 is another standout model, recognized for its compact size without sacrificing performance. This stove is designed for smaller spaces and is equipped with an innovative catalytic combustor that maximizes fuel efficiency and minimizes emissions. Its elegant design includes a variety of color options, allowing homeowners to select a finish that complements their interiors perfectly.

Moving on to the Vermont Casting 2950, this model offers a blend of tradition and modern technology. It utilizes a secondary combustion system that captures and re-burns gases released during the burning process. This leads to cleaner combustion and increased energy output. The 2950's detailed cast iron craftsmanship not only provides classic appeal but also ensures longevity.

The 2998 model stands out with its large firebox capacity, making it suitable for extended burn times. Designed for wood logs up to 20 inches, it offers an efficient heat output, making it ideal for colder climates. The stove features an easy-to-use air control that allows users to adjust the burn rate for their heating needs, promoting both efficiency and comfort.

Lastly, the Vermont Casting 2997 brings a unique blend of style and functionality. Its distinctive design includes an optional soapstone top, enhancing heat retention and providing an elegant aesthetic. With built-in features like the easy-access ash pan, homeowners can enjoy a hassle-free experience while maintaining their stove.

Overall, these Vermont Castings models showcase advanced heating technologies combined with beautiful design. Their commitment to efficiency, durability, and aesthetics makes them a popular choice for those seeking a reliable heating solution. Whether it's for the cozy ambiance or efficient warmth, Vermont Castings continues to set a standard in the wood stove industry.