Vermont Casting 1990CE installation instructions Fireplace Chimney Installations Above a Fireplace

Page 7

A special piece called the “thimble sleeve,” slightly smaller in diameter than standard connector and most thimbles, will facilitate the removal of the chimney con- nector system for inspection and cleaning. Thimble sleeves should be available from your local dealer. (Fig. 5)

Thimble Sleeve

Flue

Intrepid II Woodburning Stove

Chimney Connector

*

Shields

* Check

 

These Clear-

 

Chimney

Connector

Keep sleeve end flush with flue tile

ST243

ances

*

 

Mantel

 

Seal the

 

Damper

Fig. 5 The thimble, made of either ceramic or metal, must be cemented securely in place.

To install a thimble sleeve, slide it into the breach until it is flush with the inner flue wall. Do not extend it into the actual flue passage, as this could interfere with the draft.

The thimble sleeve should protrude 25 - 50 mm (1-2”) into the room. Use furnace cement and thin gasketing to seal the sleeve in place in the thimble. Secure the chimney connector to the outer end of the sleeve with sheet metal screws.

Without a thimble, a suitable length of chimney con- nector can be extended through the breach to the inner face of the flue liner, and cemented securely in place. Additional pieces of connector are then attached with sheet metal screws.

Fireplace Chimney Installations -

Above a Fireplace

The Intrepid II may be connected to a chimney above a fireplace opening also. In such installations, the stove is positioned on the hearth in front of the fireplace and the chimney connector rises from the stove top and then angles ninety degrees back into the chimney. (Fig. 6)

The chimney liner should extend to the point at which the chimney connector enters the chimney.

If the chimney connector from your installation enters the chimney above a fireplace, follow all the guidelines mentioned above for freestanding installations. In addi- tion, give special consideration to the following points:

Check the clearance between the stove and the chimney connector, and any combustible trim or the mantel. Use the necessary combination of mantel, trim, and connector heat shields to achieve the required clearances.

ST244

Fig. 6 Chimney connector enters chimney above the fire-

place.

Check the clearance between the chimney con-

nector and the ceiling. If no heat shields are used, the clearance should be at least 660 mm (26”). To find out how much this clearance may be reduced with heat shields, see the clearance chart on Page 14.

The fireplace damper must be sealed to prevent room air from escaping up the flue. However, it must be possible to re-open the damper to inspect or clean the chimney.

Fireplace Chimney Installations -

Through a Fireplace

If your fireplace height is at least 635 mm (25”), you may install an Intrepid II with standard legs through the fireplace opening using a “positive connection” kit available from your local dealer. These positive connec- tion kits ensure a tight fit between the stove flue collar and the chimney flue. (Fig. 7) Fireplace installations, whether connected to the flue above or through the fire- place opening, have special clearance requirements to adjacent trim and the mantel. You will find the required clearances for the Intrepid II fireplace installations on Page 9.

Floor protection requirements also apply to fireplace installations. Floor protection information is on Page 8.

30003840

7

Image 7
Contents Intrepid Welcome Table of ContentsIntrepid II, Model 1990CE SpecificationsOutside Air InstallationWhat Kind of Chimney to Use Chimney Size Chimney Connector GuidelinesMasonry Chimneys Prefabricated ChimneysFreestanding Chimney Installations Double-wall Chimney ConnectorSingle-wall Chimney Connector Securing the Single-wall Connector to a Masonry ChimneyFireplace Chimney Installations Through a Fireplace Fireplace Chimney Installations Above a FireplaceHearths Wall Pass-ThroughsKeep the Stove a Safe Distance from Surrounding Materials Floor Protection for Fireplace InstallationsClearances Summary of Clearances Assembly Attach the Griddle Handle OperationYour Intrepid II’s Controls What They Do Two Ways to Add Fuel Damper Directs Air Flow Within the StoveGlass Door Panels AndironsSurface Thermometer is a Valuable Guide to Operation Burn Only High-Quality WoodHow to Build a Wood Fire Keep it Going Use the Air Control Settings that Work Best for YouHigh-Efficiency Wood Burning With Catalytic Combustion Starting and Maintaining a Wood Fire Conditioning Your StoveAsh Disposal Refuel While the Embers are Still HotDraft Management Back-puffing Draft TestingCreosote FuelMaintenance Damper Adjustment How to Adjust the Door LatchTighten the Damper Handle as Needed When to Suspect a Combustion System Problem Catalytic Combustion System Inspection and CleaningReplace the Stove Gaskets as Needed Replace Refractory PackageChimney System Creosote Adjust the Door if NecessaryAnnual Maintenance Permanent GasketsIntrepid II Woodburning Stove Appendix Catalytic Combustor Intrepid II Woodburning Stove Intrepid II Woodburning Stove Please record the following information For future reference Intrepid II Woodburning Stove Warranty CFM Corporation

1990CE specifications

The Vermont Casting 1990CE is a remarkable wood-burning stove that has earned a solid reputation for its innovative design, efficiency, and durability. Renowned for its classic aesthetics and modern functionality, the 1990CE combines traditional craftsmanship with cutting-edge technology, making it a favorite among homeowners looking to enhance their living spaces with both warmth and style.

One of the most notable features of the 1990CE is its exceptional efficiency. The stove is designed to produce a high heat output while minimizing the consumption of wood. With an impressive efficiency rating, it effectively uses the fuel, ensuring that users enjoy longer burn times and reduced firewood usage. This efficiency not only provides warmth but also aligns with eco-friendly practices, reducing the impact on the environment.

The Vermont Casting 1990CE incorporates advanced secondary combustion technology, which allows for a cleaner burn and significantly lowers emissions. This state-of-the-art system ensures that the stove generates less smoke and reduces the amount of pollutants released into the atmosphere. As a result, users can enjoy the benefits of a cozy fire without the guilt of environmental harm.

In addition to its environmental features, the stove is built with a heavy cast iron construction, which ensures durability and longevity. The cast iron design not only provides excellent heat retention but also adds a timeless aesthetic to any home. The 1990CE is available in various finishes, allowing homeowners to select a style that complements their decor.

Another key characteristic of the Vermont Casting 1990CE is its user-friendly design. The stove features an easy-to-use air control system that allows users to adjust the intensity of the fire with ease. This precise control enables the creation of the desired ambiance, whether for a cozy evening or a more intense heating requirement.

Furthermore, the 1990CE offers a large viewing window, framed by a stylish cast iron design, allowing users to enjoy the mesmerizing flames while enhancing the overall visual appeal of the room. The stove’s clean lines and classic design make it a versatile addition to various interior styles, from rustic to contemporary.

Ultimately, the Vermont Casting 1990CE stands out for its combination of efficiency, aesthetic appeal, and user-friendly features. With its commitment to sustainable burning practices and craftsmanship, it provides an ideal solution for those seeking both warmth and style in their homes. Whether for practical heating or the simple joy of a crackling fire, the 1990CE is a remarkable choice that will serve homeowners well for years to come.