Vermont Casting 2550 installation instructions Floor Protection for Fireplace Installations

Page 10

Encore Woodburning Stove

D

B

E E

F

A

C

E E

F

A

U.S. Canada

A.39” 43” (1092 mm)

B.44” 48” (1219 mm)

C.

12”

12”

(305 mm)

8” Connector

 

10”

10”

(255 mm)

10” Connector

D.6” 8” (203 mm)

E.6” 8” (203 mm)

F.

16”

18” (459 mm)

ST500

Fig. 12 Required floor protector dimensions for both top-and rear-exiting stove.

Floor Protection for Fireplace Installations

Do not assume that your fireplace hearth is completely noncombustible.

Many fireplace hearths do not meet the “completely noncombustible” requirement because the brick or concrete in front of the fireplace opening is supported by heavy wood framing. (Fig. 13) Because heat passes through brick or concrete readily, it can easily pass through to the wood. As a result, such fireplace hearths can be a fire hazard and are considered a combustible floor.

Keep in mind, also, that many raised hearths will extend less than the required clearance from the front of the heater when it is installed. In such cases, sufficient floor protection as described above must be added in front of the hearth to satisfy the minimum floor protector requirement from the front of the stove: 16” (406mm) from the front in the United States and 18” (459mm) from the front in Canada.

Hearth rugs do not satisfy the requirements for floor protection.

Fireplace installations also have special clearance requirements to the side walls, side decorative trim, and fireplace mantel. This information follows in the section on Fireplace and Mantel Trim Shields.

Wood framing requires pro-

 

tection from radiant heat

ST247e

 

Fig. 13 Combustible supporting timbers may lie beneath fireplace hearths, requiring additional floor protection.

Keep the Stove a Safe Distance

from Surrounding Materials

Both a stove and its chimney connector radiate heat in all directions when operating, and dangerous overheat- ing of nearby combustible materials can occur if they are too close to the heat. A safe installation requires that adequate clearance be maintained between the hot stove and its connector and nearby combustibles.

Clearance is the distance between either your stove (measured from the bottom edge of the stove’s top plate) or chimney connector, and nearby walls, floors, the ceiling, and any other fixed combustible surface. Your stove has special clearance requirements that have been established after careful research and test- ing to UL and ULC standards. These clearance require- ments must be strictly observed.

In addition, furnishings and other combustible materi- als must be kept away from the stove as well. In gen- eral, a distance of 48” (1219mm) must be maintained between the stove and moveable combustible items such as drying clothes, furniture, newspapers, firewood, etc. Keeping those clearance areas empty assures that nearby surfaces and objects will not overheat.

Reducing Clearances Safely with Shields

Clearance requirements are established to meet every installation possibility, and they involve the combination of four basic variables:

When the stove and chimney connector have no listed heat shield mounted on them.

When the stove and chimney connector have a listed heat shield mounted on them.

When the wall has no listed heat shield mounted on it.

When the wall has a heat shield mounted on it.

10

2000956

Image 10
Contents Encore Table of Contents WelcomeEncore dimensions SpecificationsOutside Air InstallationChimney Height Prefabricated Chimneys What Kind of Chimney to UseMasonry Chimneys Chimney SizeDouble-wall Chimney Connectors Chimney Connector GuidelinesSingle-wall Chimney Connectors Fireplace Installations Securing the Single-wall Connector to a Masonry ChimneyFreestanding Installations Above the FireplaceThrough the Fireplace Wall Pass-ThroughsFloor Protection An approved wall pass-through for the United StatesKeep the Stove a Safe Distance From Surrounding Materials Floor Protection for Fireplace InstallationsReducing Clearances Safely with Shields Stove Heat Shields Wall ShieldsChimney Connector Heat Shields Fireplace and Mantel Trim ShieldsAlcove Installations Construction RequirementsEncore Clearance Chart Unprotected Surfaces Protected SurfacesEncore Clearance Diagrams Wall Shield Requirements for Common Installations Corner Parallel Installations Assembly Single Air Control Regulates Heat Output and Burn Time OperationEncore Controls Damper Directs Air Flow Within the StoveTwo Ways to Add Fuel Encore’s hinged griddle makes it easy to top-load woodAndirons Help Protect the Glass Use the Air Control Settings That Work Best for YouInfrared Reflective Glass Panels For Clear Fire Viewing Burn Only High-Quality WoodEncore Control Settings High-Efficiency Wood Burning with Catalytic CombustionConditioning Your Stove Starting and Maintaining a Wood FireRefuel While the Embers Are Still Hot Ash DisposalSteel Chimney Draft ManagementIndoor / Outdoor location Single venting Flue SizingPipe & Chimney Layout CreosoteMaintenance Removing the Glass Installing the GlassAdjust the Damper as Needed Check the Operation Primary Air ShutterWhen to Suspect a Combustor Problem How to Adjust the Door LatchesCatalytic Element Inspection and Cleaning Tighten the Damper Handle as NeededInspecting the Combustor Remove the lower fireback through the front door openingReplace the Stove Gaskets as Needed Gasket Diameter ...And the Parts it SealsPermanent Encore Gaskets Adjust the Door If NecessaryAnnual Maintenance Chimney System CreosoteAppendix Catalytic Combustor Encore Woodburning Stove Encore Woodburning Stove Shell Enamel Parts Encore Color Encore Woodburning Stove Encore Woodburning Stove Warranty CFM Corporation