Trane CAB-PRC001-EN manual Table PD-4. Free Discharge Motor, Group

Page 20

Performance

Hot Water

Data

Coils

 

 

 

 

Heating performance is based on 70 F (21 C) entering air temperature, 180 F (82 C) entering hot water temperature with a 30 F (-1 C) T. All performance measured on high speed tap, zero ESP, and a throwaway filter.

Table PD-4. Free Discharge Motor, Group 3

 

 

 

 

 

 

 

Heating

 

 

 

 

 

 

Unit

 

CFM

TMBH

 

GPM

WPD

115V

230V

277V

Size

Coil

(L/s)

(TkW)

Q/ITD

(L/s)

(kPa)

Watt

Watt

Watt

2

2H

198 (93)

13.8 (4.1)

0.13

0.92

(0.06)

3.8 (11.3)

60

95

65

 

3H

188 (90)

16.7 (4.9)

0.15

1.11

(0.07)

8.0 (23.8)

60

95

65

 

4H

177 (84)

17.3 (5.1)

0.16

1.16

(0.07)

2.2 (6.4)

60

95

65

3

2H

262

(124)

18.3 (5.4)

0.17

1.22

(0.08)

6.9 (20.6)

70

80

83

 

3H

260

(123)

22.1 (6.5)

0.20

1.47

(0.09)

2.9 (8.7)

85

89

101

 

4H

242

(114)

23.7 (6.9)

0.22

1.58

(0.10)

4.1 (12.3)

85

89

101

4

2H

330

(156)

22.8 (6.7)

0.21

1.52

(0.10)

2.6 (7.7)

95

96

104

 

3H

320

(151)

28.1 (8.2)

0.26

1.87

(0.12)

5.1 (15.2)

100

107

106

 

4H

304

(144)

30.3 (8.9)

0.28

2.02

(0.13)

7.3 (21.9)

100

107

106

6

2H

512

(242)

35.8

(10.5)

0.33

2.38

(0.15)

7.0 (21.0)

110

154

165

 

3H

508

(240)

43.3

(12.7)

0.39

2.88

(0.18)

3.3 (9.7)

125

130

124

 

4H

483

(228)

47.2

(13.8)

0.43

3.14

(0.20)

4.4 (13.3)

125

130

124

8

2H

665

(314)

45.0

(13.2)

0.41

3.00

(0.19)

3.2 (9.4)

135

150

159

 

3H

623

(294)

54.3

(15.9)

0.49

3.62

(0.23)

5.5 (16.3)

120

123

133

 

4H

596

(282)

59.2

(17.3)

0.54

3.94

(0.25)

7.5 (22.4)

120

123

133

10

2H

829

(391)

57.5

(16.9)

0.52

3.83

(0.24)

5.5 (16.3)

205

250

269

 

3H

835

(394)

72.9

(21.3)

0.66

4.86

(0.31)

10.5 (31.2)

225

237

230

 

4H

796

(376)

79.0

(23.1)

0.72

5.26

(0.33)

14.4 (42.9)

225

237

230

12

2H

940

(444)

66.5

(19.5)

0.60

4.43

(0.28)

7.6 (22.8)

230

246

263

 

3H

923

(436)

80.6

(23.6)

0.73

5.37

(0.34)

8.2 (24.6)

220

230

239

 

4H

876

(413)

87.9

(25.8)

0.80

5.86

(0.37)

9.4 (28.2)

220

230

239

Note:

1.CFM = Cubic feet per minute

2.TMBH = Total capacity (MBH)

3.GPM = Gallons per minute

4.WPD = Water pressure drop (feet of water)

5.Q/ITD = MBH (kW)/(Entering water temperature - Entering air temperature) when DT and GPM (L/s) remain constant. To determine heating capacities at a different entering water temperature or entering air temp, compute the new ITD and multiply it by the Q/ITD shown.

6.Medium and low speed capacities are approximately 80 percent and 60 percent respectively of the high speed capacity.

20

CAB-PRC001-EN

Image 20
Contents Force-Flo Cabinet Heater DecemberIt isn’t just a fan and a coil… Contents Features and Benefits Procedure SelectionModel Number DescriptionDigit 27 Main Control Valve Digit 28 Not UsedDigit 29 Piping Packages Digit 30 Control TypeGeneral Data Configurations UnitModel a Vertical Concealed Model B Vertical CabinetModel C Horizontal Concealed Fresh Air Outlet Model D Horizontal CabinetOutlet Inlet Model F Vertical Wall Hung Cabinet General Data Unit ConfigurationsModel E Horizontal Recessed Model H Vertical RecessedModel J Vertical Cabinet Slope TopModel N Inverted Vertical Recessed General DataModel M Inverted Vertical Cabinet Table GD-1. Force-Flo Cabinet Heater General Data Table GD-2. Cabinet Heater Air FlowElectric Heat Electric HeatFactory-Installed Piping Packages Piping PackagesGeneral Data Piping Package OptionsSelecting the Correct Modulating Valve Size Performance Hot WaterData CoilsTable PD-2. Free Discharge Motor, Group Table PD-3. Free Discharge Motor, GroupTable PD-4. Free Discharge Motor, Group Table PD-5. High Static Motor, Group Table PD-6. High Static Motor, GroupPerformance Steam DataCoils Table PD-7. Free Discharge Motor, GroupTable PD-8. Free Discharge Motor, Group Table PD-9. Free Discharge Motor, GroupTable PD-12. Steam Properties Table PD-10. High Static Motor, GroupTable PD-11. High Static Motor, Group Manual Fan Mode Switch ControlsControl Options Tracer ControlsSequence of Operation SequenceControls Operation Table C-2. Controller Function Summary General Controls InformationTable C-1. Controller Input/Output Summary Zone Sensor Controls OptionsZone Sensor Options ZN.010ZN.520 Additional Features Controls FeaturesControl Features Control Valve Two-Position Fresh Air Damper Actuator End Device OptionsTwo-Position Control Valves Electrical Data Units with Electric HeatCalculating MCA Calculating MFSRPM Table ED-6. Two-Stage Electric Heat Digit 18 = U Table ED-7. Single-Stage, Max kW Electric Heat Digit 18 = N Table ED-8. Single Stage, Low kW Electric Heat Digit 18 =Table DW-2. Shipping Weights lbs. kg Dimensions WeightsTable DW-1. Operating Weights lbs. kg Dimensions Vertical Concealed Unit DimensionsVertical ConcealedVertical Cabinet Unit Dimensions Vertical Cabinet, Model BHorizontal Concealed, Model C Horizontal Concealed Unit DimensionsHorizontal Horizontal Cabinet, Model D Horizontal Cabinet Unit DimensionsCabinet Horizontal Recessed, Model E Horizontal Recessed Unit DimensionsRecessed Vertical Wall Hung Cabinet, Model F Vertical Wall Hung Cabinet Unit DimensionsWall Hung Vertical Recessed Unit Dimensions Vertical Recessed, Model HVertical Slope Top, Model J Vertical Slope Top Unit DimensionsSlope Top Inverted Vertical Cabinet, Model M Inverted Vertical Cabinet Unit DimensionsInverted Vertical Inverted Vertical Recessed Unit Dimensions Inverted Vertical Recessed, Model NCoil ConnectionsCoil Connections Vertical Units Horizontal Units Inverted UnitsOpening Fresh Air Opening Dimensions, Horizontal UnitsFresh Air Fresh Air Opening Dimensions, Vertical Units Wall Box Continuous Mortar Ribs TOP and BottomProjection Panel Dimensions Projection PanelProjection Panel Dimensions Mechanical Specifications Electric Heat Coil FiltersFresh Air Damper Manual DamperMechanical Specifications Options False Backs Recessing FlangesAluminum Wall Boxes Projection PanelsAuto Circuit Setter Piping Components Ball ValveManual Circuit Setter Control Valve Balance FittingUnion StrainerTrane Company Division of American Standard Inc

CAB-PRC001-EN specifications

The Trane CAB-PRC001-EN is an advanced control system designed to enhance the efficiency and performance of commercial heating, ventilation, and air conditioning (HVAC) systems. This building automation system plays a crucial role in optimizing indoor climate conditions while maximizing energy savings.

One of the standout features of the CAB-PRC001-EN is its capability for real-time monitoring and control. The system integrates seamlessly with various HVAC components, allowing users to adjust settings, schedules, and operational modes from a centralized interface. This flexibility ensures that building managers can respond promptly to changes in occupancy or external weather conditions, optimizing comfort while minimizing energy consumption.

The CAB-PRC001-EN employs a robust set of advanced technologies aimed at enhancing system reliability. Utilizing adaptive control algorithms, it intelligently balances heating and cooling loads across different zones, ensuring a consistent temperature environment throughout the building. The system can quickly adapt to variable load conditions, improving energy efficiency and reducing wear on equipment.

Another defining characteristic is its commitment to user-friendly operation. The intuitive interface utilizes a clear graphical display, making navigation straightforward for users of all skill levels. Furthermore, the system can be accessed remotely through web-enabled devices, providing convenience and flexibility for building managers who are often on the move.

Integration capabilities are another hallmark of the CAB-PRC001-EN. It is designed to work with a multitude of third-party devices and protocols, enabling a comprehensive building management solution. This compatibility allows for smooth communication between different systems, including lighting, security, and fire safety systems, fostering an environment of enhanced operational efficiency.

In addition, the CAB-PRC001-EN supports advanced analytics and reporting features. Users can generate detailed reports on energy usage, system performance, and maintenance needs, enabling informed decision-making that can lead to further energy savings and improved system longevity.

In summary, the Trane CAB-PRC001-EN control system is a cutting-edge solution designed for commercial buildings, offering a combination of real-time monitoring, advanced control technologies, user-friendly interfaces, seamless integration capabilities, and powerful analytics. This makes it an ideal choice for any organization looking to enhance their HVAC operations while promoting sustainability and energy efficiency.