Trane CAB-PRC001-EN manual Mechanical Specifications

Page 50

Mechanical Specifications

Force–Flo™ Cabinet Heater Mechanical Specifications

Performance Data

Capacity: Unit capacities are in accor- dance with Industry Room Fan-Coil Air Conditioner Certification Program under ARI Standard 440-97. Safety: All standard units are UL listed in the United States and Canada. Units comply with NFPA90A requirements.

Construction

All Units

The unit includes a chassis, coil, fan wheel(s), fan casing(s), fan board and motor(s). The fan board assembly is easily removable. The fan board assem- bly includes a quick-disconnect motor plug. The chassis construction is 18- gauge galvanized steel, and continuous throughout the unit. The unit is acousti- cally and thermally insulated with closed- cell insulation. All panels are made rigid by channel forming.

Vertical Cabinet and Slope Top Units Front panel fabrication is 16-gauge galvanized steel. All other panels are 18- gauge galvanized steel. Hinged access door construction is 20-gauge steel and is flush with top panel.

Vertical Wall Hung Unit

Front panel fabrication is 16-gauge galvanized steel. All other panels are 18- gauge galvanized steel. Side panels are removable for piping access.

Horizontal Cabinet Units

All panels are 18-gauge galvanized steel, including the bottom panel. The hinged access door is flush with front panel. Bottom panels ship with tamperproof screw fasteners and safety chain.

Concealed/Recessed Units

Exposed panels on recessed units are 18- gauge steel construction and ship separate from the unit. Bottom panels on horizontal recessed models ship with tamperproof screw fasteners and safety chain.

Unit Finish

All cabinet parts and exposed recessed panels are cleaned, bonderized, phos-

phatized, and painted with a baked powder finish available in six decorator colors. Standard finish meets ASTM B117 specifications (salt spray test).

Fans

The aluminum fan wheels are centrifugal forward-curved and double-width. Fan wheels and housings are corrosion resistant. Fan housing construction is formed sheet metal.

Motors

All permanent split capacitor motors are run tested in assembled units. All motors have integral thermal overload protection with a maximum ambient operating temperature of 104 F and are perma- nently lubricated. Motors are capable of starting at 78 percent of rated voltage and operating at 90 percent of rated voltage on all speed settings. Motors can operate up to 10 percent over voltage.

Hot Water Coils

Hot water coils are burst tested at 450 psig (3,103 kPa) (air) and leak tested at 100 psig (690 kPa) (air under water).

Maximum main coil working pressure is 300 psig (2,069 kPa). Maximum entering water temperature is 200 F (93 C). Tubes and u-bends are 3/8”(10 mm) OD copper. Fins are aluminum and are mechanically bonded to the copper tubes. Coil stubouts are 5/8”(16 mm) OD copper tubing.

Steam Coils

The steam heating coil is a one-row, tube- in-tube distributing type coil. Coil con- struction is aluminum fins mechanically bonded with 1” (25 mm) OD copper tubing. Steam coils are (air) burst tested at 250 psig (1,724 kPa). Maximum steam coil working pressure is 100 psig (689 kPa). Maximum entering steam tempera- ture is 325 F (163 C). Tubes and u-bends are 5/8” (16 mm) OD copper. Fins are aluminum, 9 fpi, and are mechanically bonded to the copper tubes. Coil stubouts are 1” (25 mm) OD copper tubing. Piping is field-supplied.

Piping Packages (Hot Water Coils Only) All piping packages are burst tested at 450 psig (3,103 kPa) (air) and leak tested at 100 psig (690 kPa) (air under water). The maximum working pressure of the interconnecting piping is 300 psig (2,069 kPa).

Piping packages are available in either basic or deluxe configurations. The deluxe package includes unions at the coil connections and a 20 mesh strainer on the supply side with a pressure rating on the strainer of up to 400 psig (2,758 kPa). The basic package does not include either unions or the strainer.

End valve options available on both the basic and deluxe piping packages include ball valves, manual circuit setters, and auto circuit setters.

Ball Valve Supply and Return

A ball-type stop valve is on the piping supply and return. The ball valve is a shutoff valve only with a maximum working pressure of 400 psig (2,758 kPa).

Ball Valve Supply, Manual Circuit Setter Return

A ball valve is provided on the supply with a manual circuit setter on the return. The manual circuit setter is a combina- tion flow-setting device and shutoff valve that includes two Schrader ports. The maximum working pressure of the valve is 300 psig (2,069 kPa).

Ball Valve S & R, Auto Circuit Setter Return

Ball type end valves are mounted on the supply and return, with an additional auto circuit setter mounted on the return. The auto circuit setter is an automatic flow control valve that is sized to allow a specific GPM through the coil. Auto circuit setters also include two P/T plugs and have a maximum working pressure of 400 psig (2,758 kPa).

Two-Way, Two-Position Control Valves When using two-way valves, use some means such as a pump and chiller bypass to ensure the maximum closed off DP rating of the valve is not exceeded. Two- way, two-position valves are rated for a maximum pressure differential across the valves of 25 psig (172 kPa). The valves are also available with a close-off pressure of 50 psig (345 kPa). The valve actuator is easily removable for service without removing the valve body from piping.

50

CAB-PRC001-EN

Image 50
Contents Force-Flo Cabinet Heater DecemberIt isn’t just a fan and a coil… Contents Features and Benefits Model Number ProcedureSelection DescriptionDigit 29 Piping Packages Digit 27 Main Control ValveDigit 28 Not Used Digit 30 Control TypeModel a Vertical Concealed General Data ConfigurationsUnit Model B Vertical CabinetModel C Horizontal Concealed Fresh Air Outlet Model D Horizontal CabinetOutlet Inlet Model F Vertical Wall Hung Cabinet General Data Unit ConfigurationsModel E Horizontal Recessed Model J Model HVertical Recessed Vertical Cabinet Slope TopModel N Inverted Vertical Recessed General DataModel M Inverted Vertical Cabinet Table GD-1. Force-Flo Cabinet Heater General Data Table GD-2. Cabinet Heater Air FlowElectric Heat Electric HeatFactory-Installed Piping Packages Piping PackagesGeneral Data Piping Package OptionsSelecting the Correct Modulating Valve Size Data PerformanceHot Water CoilsTable PD-2. Free Discharge Motor, Group Table PD-3. Free Discharge Motor, GroupTable PD-4. Free Discharge Motor, Group Table PD-5. High Static Motor, Group Table PD-6. High Static Motor, GroupTable PD-8. Free Discharge Motor, Group Performance Steam DataCoilsTable PD-7. Free Discharge Motor, Group Table PD-9. Free Discharge Motor, GroupTable PD-12. Steam Properties Table PD-10. High Static Motor, GroupTable PD-11. High Static Motor, Group Control Options Manual Fan Mode SwitchControls Tracer ControlsSequence of Operation SequenceControls Operation Table C-2. Controller Function Summary General Controls InformationTable C-1. Controller Input/Output Summary Zone Sensor Options Zone SensorControls Options ZN.010ZN.520 Additional Features Controls FeaturesControl Features Control Valve Two-Position Fresh Air Damper Actuator End Device OptionsTwo-Position Control Valves Calculating MCA Electrical DataUnits with Electric Heat Calculating MFSRPM Table ED-6. Two-Stage Electric Heat Digit 18 = U Table ED-7. Single-Stage, Max kW Electric Heat Digit 18 = N Table ED-8. Single Stage, Low kW Electric Heat Digit 18 =Table DW-2. Shipping Weights lbs. kg Dimensions WeightsTable DW-1. Operating Weights lbs. kg Vertical DimensionsVertical Concealed Unit Dimensions ConcealedVertical Cabinet Unit Dimensions Vertical Cabinet, Model BHorizontal Concealed, Model C Horizontal Concealed Unit DimensionsHorizontal Horizontal Cabinet, Model D Horizontal Cabinet Unit DimensionsCabinet Horizontal Recessed, Model E Horizontal Recessed Unit DimensionsRecessed Vertical Wall Hung Cabinet, Model F Vertical Wall Hung Cabinet Unit DimensionsWall Hung Vertical Recessed Unit Dimensions Vertical Recessed, Model HVertical Slope Top, Model J Vertical Slope Top Unit DimensionsSlope Top Inverted Vertical Cabinet, Model M Inverted Vertical Cabinet Unit DimensionsInverted Vertical Inverted Vertical Recessed Unit Dimensions Inverted Vertical Recessed, Model NCoil Connections Vertical Units CoilConnections Horizontal Units Inverted UnitsOpening Fresh Air Opening Dimensions, Horizontal UnitsFresh Air Fresh Air Opening Dimensions, Vertical Units Wall Box Continuous Mortar Ribs TOP and BottomProjection Panel Dimensions Projection PanelProjection Panel Dimensions Mechanical Specifications Fresh Air Damper Electric Heat CoilFilters Manual DamperMechanical Specifications Options Aluminum Wall Boxes False BacksRecessing Flanges Projection PanelsAuto Circuit Setter Piping Components Ball ValveManual Circuit Setter Union Control ValveBalance Fitting StrainerTrane Company Division of American Standard Inc

CAB-PRC001-EN specifications

The Trane CAB-PRC001-EN is an advanced control system designed to enhance the efficiency and performance of commercial heating, ventilation, and air conditioning (HVAC) systems. This building automation system plays a crucial role in optimizing indoor climate conditions while maximizing energy savings.

One of the standout features of the CAB-PRC001-EN is its capability for real-time monitoring and control. The system integrates seamlessly with various HVAC components, allowing users to adjust settings, schedules, and operational modes from a centralized interface. This flexibility ensures that building managers can respond promptly to changes in occupancy or external weather conditions, optimizing comfort while minimizing energy consumption.

The CAB-PRC001-EN employs a robust set of advanced technologies aimed at enhancing system reliability. Utilizing adaptive control algorithms, it intelligently balances heating and cooling loads across different zones, ensuring a consistent temperature environment throughout the building. The system can quickly adapt to variable load conditions, improving energy efficiency and reducing wear on equipment.

Another defining characteristic is its commitment to user-friendly operation. The intuitive interface utilizes a clear graphical display, making navigation straightforward for users of all skill levels. Furthermore, the system can be accessed remotely through web-enabled devices, providing convenience and flexibility for building managers who are often on the move.

Integration capabilities are another hallmark of the CAB-PRC001-EN. It is designed to work with a multitude of third-party devices and protocols, enabling a comprehensive building management solution. This compatibility allows for smooth communication between different systems, including lighting, security, and fire safety systems, fostering an environment of enhanced operational efficiency.

In addition, the CAB-PRC001-EN supports advanced analytics and reporting features. Users can generate detailed reports on energy usage, system performance, and maintenance needs, enabling informed decision-making that can lead to further energy savings and improved system longevity.

In summary, the Trane CAB-PRC001-EN control system is a cutting-edge solution designed for commercial buildings, offering a combination of real-time monitoring, advanced control technologies, user-friendly interfaces, seamless integration capabilities, and powerful analytics. This makes it an ideal choice for any organization looking to enhance their HVAC operations while promoting sustainability and energy efficiency.