INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

For Vintage Oak Model

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Locate pegs on the bottom of back log (#1). Slide these pegs into the holes in the grate base behind the burner (see Figure 17).

2.Locate the notches on the back of the front log (#2). Slide these notches over the tabs of the grate base (see Figure 18).

3.Locate the notches in the bottom of the crossover log (#3). Place the crossover log on top of the back log and front log. Make sure the notches of the crossover log line up with rectangular knobs on top of the back and front logs (see Fig- ure 19).

4.Add lava rock around base of heater.

Back Log (#1)

Peg

Hole

Peg

Figure 17 - Installing Back Log

Front

Log (#2)

Notch

Tabs of

Grate Base

Figure 18 - Installing Front Log

Crossover

Notch

Log (#3)

 

Rectangular

Knob

Notch

Rectangular

Knob

Figure 19 - Installing Crossover Log

For Golden Oak or Birch Models

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place one-piece log set on grate to fit as illustrated in Figure 20. Make sure middle section at bottom of log set is seated into “U”-shaped cutout in cen- ter of chassis (see Figure 20). Note: 36” and birch models have more features but fit on the chassis the same. Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner parts.

2.Place lava rock around base of heater.

One-Piece

Log Set

Middle Section at Bottom of Log Set

Chassis

Burner

“U”-shaped Cutout

in Chassis

Figure 20 - Installing Golden Oak or Birch One-Piece Log Set

Burner

One-Piece

Log Set

Figure 21 - Installing Golden Oak or Birch One-Piece Log Set (Top View)

14

104343

Image 14
Contents Log Design What to do if YOU Smell GASOak Log Design Patent PendingSafety Information Vanguard FLAME-MAX Unvented PROPANE/LP GAS LOG HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining Fresh AIR Flow for Heater Location Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Minimum Non-combustible Material Clearances If Not Using MantelIf Using Mantel Floor Clearances Determining Minimum Mantel Clear- ance When using a HoodMantel Clearances Determining Minimum Mantel ClearanceChimney Minimum Permanent Height ft Flue Opening sq. ins Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Golden Oak and Birch Model Chassis Installation Items NeededStandard Oak Log Chassis Connecting to GAS Supply Accessories,Checking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Test Pressures Equal To or Less Than 1/2 PsigFor Golden Oak or Birch Models Installing LogsFor Vintage Oak Model Operating Heater Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureVariable Control Operation Shutting Off HeaterPilot Flame Pattern Inspecting BurnersThermostat Control Operation Main BurnerTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Top Gas leak. See Warning statement atOptional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceSpecifications ODS/PILOT and Burner Cleaning and MaintenanceReplacement Parts LogsODS Pilot Illustrated Parts BreakdownFLAME-MAX Vintage OAK Models VYS18P and VYS24P Parts List VYS18P VYS24P1117 612 VYD18P, VYBD18P VYD24P, VYBD24P VYD30P, VYBD30P VYD36P Thermostatically Controlled Models VYD18PT VYD24PT VYD30PT VYD18PT VYD24PT VYD30PT VYD18PT VYD24PT VYD30PTTechnical Service AccessoriesService Hints Manual Shutoff104343 Warranty Information

PRVYS18PWA specifications

Vanguard Managed Solutions PRVYS18PWA is a cutting-edge technology platform designed to revolutionize the way individuals and businesses manage their financial investments. This innovative solution combines advanced tools and features to provide a comprehensive approach to asset management.

One of the standout features of PRVYS18PWA is its intuitive user interface, which makes navigating and using the platform a seamless experience for users of all skill levels. The dashboard provides real-time insights and analytics, enabling users to track their investments’ performance easily. Powerful reporting tools are integrated, offering detailed summaries and projections that help users make educated financial decisions.

PRVYS18PWA utilizes state-of-the-art algorithms and machine learning technologies to analyze market data and trends. This feature allows users to receive personalized investment recommendations tailored to their financial goals and risk tolerance. AI-driven tools continuously learn from user interactions, ensuring that the advice provided remains relevant and up-to-date.

Security is a top priority for Vanguard Managed Solutions, and PRVYS18PWA is no exception. The platform incorporates advanced encryption protocols and two-factor authentication to protect sensitive data, ensuring that user information and financial assets are secure at all times. Users can feel confident in their transactions and the integrity of their personal information.

Another impressive characteristic of PRVYS18PWA is its integration capabilities. The platform can seamlessly connect with various financial institutions and other investment tools, allowing users to consolidate all their financial data in one place. This integration streamlines the management process and provides a holistic view of an individual’s or organization’s finances.

For those keen on sustainability, PRVYS18PWA offers various eco-conscious investment options. The platform allows users to explore socially responsible investment opportunities, aligning with personal values and promoting a positive impact on society and the environment.

Furthermore, PRVYS18PWA includes robust educational resources, ensuring users have access to the knowledge needed to make informed investments. From industry insights to market analyses and investment strategies, users can enhance their financial literacy and make more confident decisions.

Overall, Vanguard Managed Solutions PRVYS18PWA is an exceptional investment management tool that combines user-friendly design, advanced technologies, and educational resources to empower users on their financial journeys. Whether a novice investor or a seasoned professional, PRVYS18PWA offers features and functionalities to meet diverse needs and promote financial growth.