Vanguard Heating VSGF28PVA installation manual OWNER’S Operation and Installation Manual

Page 1

®

UNVENTED (VENT-FREE)

PROPANE/LP GAS FIREPLACE

OWNER’S OPERATION AND INSTALLATION MANUAL

Variable Manually-

¢QQQQQQ;;;;;;¢¢¢¢¢

 

Controlled Model

 

VSGF28PVA

 

Thermostatically-

 

Controlled Model

Shown with

VSGF28PTC

 

with Split Oak Logs

 

optional cabinet

 

 

mantel, hearth

 

 

base, and trim

 

 

accessories.

WARNING: If the information in this manual is not fol- lowed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s in- structions.

If you cannot reach your gas supplier, call the fire department.

Installation and service must be performed by a quali- fied installer, service agency, or the gas supplier.

WARNING: Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installation and operational procedures. For assistance or additional infor- mation consult a qualified in- staller, service agency, or the gas supplier.

WARNING: This is an unvented gas-fired heater. It uses air (oxy- gen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation sec- tion on page 4 of this manual.

This appliance may be installed in an aftermarket,* permanently located, manufactured (mobile) home, where not prohibited by local codes.

This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents VSGF28PVA OWNER’S Operation and Installation ManualVSGF28PTC What to do if YOU Smell GASUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupConventional Fireplace Installation Installation ClearancesActual Framing Height 32 3/8 Front Width Depth BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Attaching Flexible Gas Lines Together Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Notches Screws for Mounting Screen Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat-Controlled ModelsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower Operation Model VSGF28PTC Variable Control OperationModel VSGF28PV Blower Kit Model GA3750 SeriesPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Blower Kit Model GA3650T SeriesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Replacement Parts Technical ServiceService Hints Wiring DiagramCorner Mantel Cleaning KIT GCKCorner Hearth Base Equipment Shutoff Valve GA5010Illustrated Parts Breakdown KEY Part Number Description QTY Parts ListFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.