Vanguard Heating VSGF28PTC, VSGF28PVA Unvented PROPANE/LP GAS Fireplace, Safety Information

Page 2

®

UNVENTED PROPANE/LP GAS FIREPLACE

SAFETY

INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause seri- ous injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Propane/LP Gas: Propane/LP gas is odor- less. An odor-making agent is added to the gas. The odor helps you detect a gas leak. How- ever, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not ap- proved for use with this fireplace.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Fireplace front and screen be- come very hot when running fire- place. Keep children and adults away from hot surfaces to avoid burns or clothing ignition. Fire- place will remain hot for a time after shutdown. Allow surfaces to cool before touching.

Carefully supervise young chil- dren when they are in the room with fireplace. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this fireplace with the fireplace screen and hood in place. Make sure fire- place screen and hood are in place before running fireplace.

Keep the appliance area clear and free from combustible materials, gasoline, and other flammable vapors and liquids.

1.This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible for use with other gases.

2.Do not place propane/LP supply tank(s) inside any structure. Locate propane/ LP supply tank(s) outdoors.

3.If you smell gas

shut off gas supply

do not try to light any appliance

do not touch any electrical switch; do not use any phone in your building

immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions

if you cannot reach your gas supplier, call the fire department

4.This fireplace shall not be installed in a bedroom or bathroom.

5.Do not use this fireplace as a wood- burning fireplace. Use only the logs provided with the fireplace.

6.Do not add extra logs or ornaments such as pine cones, vermiculite, or rock wool. Using these added items can cause sooting. Do not add lava rock around base. Rock and debris could fall into the control area of fireplace.

7.This fireplace is designed to be smoke- less. If logs ever appear to smoke, turn off fireplace and call a qualified ser- vice person. Note: During initial op- eration, slight smoking could occur due to log curing and fireplace burning manufacturing residues.

8.To prevent the creation of soot, follow the instructions in Cleaning and Main- tenance, page 18.

9.Before using furniture polish, wax, car- pet cleaner, or similar products, turn heater off. If heated, the vapors from these products may create a white pow- der residue within burner box or on adjacent walls or furniture.

10.This fireplace needs fresh air ventila- tion to run properly. This fireplace has an Oxygen Depletion Sensing (ODS) safety shutoff system. The ODS shuts down the fireplace if not enough fresh air is available. See Air for Combus- tion and Ventilation, pages 4 through 6. If fireplace keeps shutting off, see Troubleshooting, pages 19 through 21.

11.Do not run fireplace

• where flammable liquids or vapors are used or stored

• under dusty conditions

12.Do not use this fireplace to cook food or burn paper or other objects.

13.Do not use fireplace if any part has been exposed to or under water. Immediately call a qualified service technician to inspect the fireplace and to replace any part of the control system and any gas control which has been under water.

14.Do not operate fireplace if any log is broken. Do not operate fireplace if a log is chipped (dime-sized or larger).

15.Turn fireplace off and let cool before servicing. Only a qualified service per- son should service and repair fireplace.

For more information, visit www.desatech.com

2

107156

Image 2
Contents VSGF28PTC OWNER’S Operation and Installation ManualVSGF28PVA What to do if YOU Smell GASSafety Information Unvented PROPANE/LP GAS FireplaceUnpacking Product IdentificationLocal Codes Product Features AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Actual Framing Height 32 3/8 Front Width DepthInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Connecting Fireplace to GAS Supply Attaching Flexible Gas Lines TogetherChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Installing Logs Notches Screws for Mounting ScreenLighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat-Controlled ModelsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Model VSGF28PV Variable Control OperationBlower Operation Model VSGF28PTC Blower Kit Model GA3750 SeriesFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Blower Kit Model GA3650T SeriesLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints Technical ServiceReplacement Parts Wiring DiagramCorner Hearth Base Cleaning KIT GCKCorner Mantel Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List KEY Part Number Description QTYFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.