Vanguard Heating VSGF28PVA Inspecting Burners, Pilot Flame Pattern, Front Burner Flame Pattern

Page 17

OWNER’S MANUAL

OPERATING

FIREPLACE

Continued

Blower Kit Model GA3650T Series

Locate the blower switch by opening the lower louver on fireplace. Blower switch is located at lower left inside louver door.

The GA3650T thermostat-controlled blower has a variable speed control with an ON/OFF switch. The blower will start when the thermostat senses a sufficient increase in firebox temperature.

IMPORTANT: Light your gas appliance with the blower off.

Note for GA3650T: If you are using GA3650T blower, your gas fireplace and blower will not turn on and off at the same time. The fireplace may run for several minutes before the blower turns on. After the heater modulates to the pilot position, the blower will continue to run. The blower will shut off after the firebox temperature decreases.

Note: It is safe to operate fireplace with blowerturnedoff.However,theblowerhelps distribute heated air from the fireplace.

Note: Periodically check the louvers of the firebox and remove any dust, dirt, or other obstructions.

Follow installation instructions included with the blower accessory.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 32 shows a correct pilot flame pat- tern. Figure 33 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the fireplace will shut down.

If pilot flame pattern is incorrect, as shown in Figure 33

turn fireplace off (seeTo Turn Off Gas to Appliance, page 15 [Thermostat-con- trolled models] or page 16 [Manually- controlled models])

seeTroubleshooting, pages 19 through 21

Pilot Burner

Thermocouple

Figure 32 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 33 - Incorrect Pilot Flame Pattern

FRONT BURNER FLAME PATTERN

Figure 34 shows correct front burner flame pattern. Figure 35 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

WARNING: If front burner flame pattern shows yellow tip- ping, your fireplace could pro- duce increased levels of carbon monoxide. Follow instructions at bottom of this page. Yellow flame on rear burner is normal.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by fireplace, causing brief patches of orange flame.

If front burner flame pattern is incorrect, as shown in Figure 35

turn fireplace off (seeTo Turn Off Gas to Appliance, page 15 [Thermostat-con- trolled models] or page 16 [Manually- controlled models])

seeTroubleshooting, pages 19 through 21

Figure 34 - Correct Front Burner Flame

Pattern

Yellow Tipping At

Top of Blue Flame

Figure 35 - Incorrect Front Burner Flame Pattern

107156

17

For more information, visit www.desatech.com

Image 17
Contents VSGF28PVA OWNER’S Operation and Installation ManualVSGF28PTC What to do if YOU Smell GASUnvented PROPANE/LP GAS Fireplace Safety InformationUnpacking Product IdentificationLocal Codes AIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Fireplace Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installing Hood InstallationCheck GAS Type Electrical HookupConventional Fireplace Installation Installation ClearancesActual Framing Height 32 3/8 Front Width Depth BUILT-IN Fireplace InstallationInstallation Items Needed Installing GAS Piping to Fireplace LocationMantel Clearances for Built-In Installation Attaching Flexible Gas Lines Together Connecting Fireplace to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Fireplace Gas Connections Notches Screws for Mounting Screen Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat-Controlled ModelsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Blower Operation Model VSGF28PTC Variable Control OperationModel VSGF28PV Blower Kit Model GA3750 SeriesPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Blower Kit Model GA3650T SeriesLogs Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Replacement Parts Technical ServiceService Hints Wiring DiagramCorner Mantel Cleaning KIT GCKCorner Hearth Base Equipment Shutoff Valve GA5010Illustrated Parts Breakdown KEY Part Number Description QTY Parts ListFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.