Vanguard Heating VSGF28PVA, VSGF28PTC Installing Logs, Notches Screws for Mounting Screen

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front log (#1) on top of the grate. Make sure the notches in the bottom of the log fit over the grate prongs (see Figure 35). Push back of log flush with metal grate bar.

2.Rest middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate (see Figure 36). Bring the log forward next to the metal posts.

3.Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 37).

4.Place the crossover log (#4) on the rear log and the middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The cross- over log should fit in the cutout of the middle log (see Figure 38).

Front Log (#1)

Notch

Grate

Prongs

Metal Grate Bar

Figure 23 - Installing Front Log (#1)

Middle Log (#2)

Groove

Metal

Post

Groove

Grate

Metal Post

Figure 24 - Installing Middle Log (#2)

Groove

Peg

in Back

of Log

Rear Log

(#3)

 

Grate Prong

 

Rear

 

Burner

Groove

 

in Back

 

of Log

 

Grate

 

Prong

Crossover

Log (#4)

CutoutHole

Peg

Figure 26 - Installing Crossover Log (#5)

Notches

Screws for

Mounting

Screen

Figure 27 - Installing Fireplace Screen

WARNING: You must operate this fireplace with the fireplace screen in place. Make sure fire- place screen is in place before running fireplace.

5.Install fireplace screen by slipping notches of fireplace screen over screws on front of fireplace (see Figure 39).

Figure 25 - Installing Rear Log (#3)

107156

13

For more information, visit www.desatech.com

Image 13
Contents VSGF28PVA OWNER’S Operation and Installation ManualVSGF28PTC What to do if YOU Smell GASUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installing Hood InstallationCheck GAS Type Electrical HookupConventional Fireplace Installation Installation ClearancesActual Framing Height 32 3/8 Front Width Depth BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Attaching Flexible Gas Lines Together Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Notches Screws for Mounting Screen Installing LogsOperating Fireplace For Your Safety Read Before LightingLighting Instructions Thermostat-Controlled ModelsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower Operation Model VSGF28PTC Variable Control OperationModel VSGF28PV Blower Kit Model GA3750 SeriesPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Blower Kit Model GA3650T SeriesCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Replacement Parts Technical ServiceService Hints Wiring DiagramCorner Mantel Cleaning KIT GCKCorner Hearth Base Equipment Shutoff Valve GA5010Illustrated Parts Breakdown KEY Part Number Description QTY Parts ListFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.