Vanguard Heating VSGF28PTC, VSGF28PVA installation manual Cleaning and Maintenance, Logs

Page 18

®

UNVENTED PROPANE/LP GAS FIREPLACE

CLEANING AND MAINTENANCE

WARNING: Turn off fireplace and let cool before cleaning.

CAUTION: You must keep control areas, burners, and circu- lating air passageways of fireplace clean. Inspect these areas of fire- place before each use. Have fire- place inspected yearly by a quali- fied service person. Fireplace may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This pro- vides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every three months during operation and have heater in- spected yearly by a qualified service person.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 36).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 37). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 36 - Injector Holder On Outlet Burner Tube

Ports/Slots

Burner

Tube

Pilot

Assembly

Pilot Air

Inlet

Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Figure 37 - Pilot Inlet Air Hole

For more information, visit www.desatech.com

18

107156

Image 18
Contents VSGF28PTC OWNER’S Operation and Installation ManualVSGF28PVA What to do if YOU Smell GASSafety Information Unvented PROPANE/LP GAS FireplaceProduct Identification Local CodesUnpacking Product Features AIR for Combustion and VentilationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Fireplace LocationDetermining if You Have a Confined or Unconfined Space Ventilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationInstalling Hood Electrical HookupInstallation Clearances Conventional Fireplace InstallationBUILT-IN Fireplace Installation Actual Framing Height 32 3/8 Front Width DepthInstalling GAS Piping to Fireplace Location Mantel Clearances for Built-In InstallationInstallation Items Needed Connecting Fireplace to GAS Supply Attaching Flexible Gas Lines TogetherPressure Testing Gas Supply Piping System Pressure Testing Fireplace Gas ConnectionsChecking GAS Connections Installing Logs Notches Screws for Mounting ScreenLighting Instructions For Your Safety Read Before LightingOperating Fireplace Thermostat-Controlled ModelsManual Lighting Procedure To Turn OFF GAS To ApplianceThermostat Control Operation Model VSGF28PV Variable Control OperationBlower Operation Model VSGF28PTC Blower Kit Model GA3750 SeriesFront Burner Flame Pattern Inspecting BurnersPilot Flame Pattern Blower Kit Model GA3650T SeriesCleaning and Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement Service Hints Technical ServiceReplacement Parts Wiring DiagramCorner Hearth Base Cleaning KIT GCKCorner Mantel Equipment Shutoff Valve GA5010Illustrated Parts Breakdown Parts List KEY Part Number Description QTYFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.