INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your primary heating system. Do not install this heater as your pri- mary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified ser- vice person must install fireplace. Follow all local codes.

WARNING: Never install the fireplace

in a bedroom or bathroom

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the fireplace

in high traffic areas

in windy or drafty areas

WARNING:ModelsVSGF28PTC have a three-prong, grounded electrical plug. This plug helps protect you against electrical shock. Only connect plug to a properly grounded, three-prong receptacle. Do not cut or remove the grounding prong from this plug.

CAUTION: This fireplace cre- ates warm air currents. These cur- rents move heat to wall surfaces next to fireplace. Installing fire- place next to vinyl or cloth wall coverings or operating heater where impurities (such as, but not limited to, tobacco smoke, aromatic candles, cleaning flu- ids, oil or kerosene lamps, etc.) in the air exist, may discolor walls or cause odors.

Note: Your fireplace is designed to be used in zero clearance installations. Wall or fram- ing material can be placed directly against any exterior surface on the rear, sides, or top of your fireplace, except where standoff spacers are integrally attached. If standoff spacers are attached to your fireplace, these spacers can be placed directly against wall or framing materials.

Use the dimensions shown for rough openings to create the easiest installation (see Built-In Fireplace Installation, pages 9 and 10).

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing fireplace in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

IMPORTANT: Make sure the fireplace is level. If fireplace is not level, log set will not work properly.

CHECK GAS TYPE

Use only propane/LP gas. If your gas supply is not propane/LP gas, do not install fire- place. Call dealer where you bought fire- place for proper type fireplace.

ELECTRICAL HOOKUP

(Model VSGF28PTC or VSGF28PVA with GA3750 or GA3650T Series Blower)

This fireplace has a blower assembly with an electrical cord. The electrical cord is five feet in length. You must locate fireplace within reach of a 120-volt grounded electrical out- let. If not, you must install an electrical outlet within reach of fireplace power cord. The GA3555 outlet accessory may be used for built-in installation when a blower is in- stalled. This same information applies if installing optional blower accessories to Model VSGF28PVA.

INSTALLING HOOD

Install hood to rail already installed in fire- place as shown in Figure 5. Use 3 Phillips screws provided.

Hood

Rail

Screw

Figure 5 - Installing Hood

Continued

107156

7

For more information, visit www.desatech.com

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualVSGF28PVA VSGF28PTCUnvented PROPANE/LP GAS Fireplace Safety InformationLocal Codes Product IdentificationUnpacking AIR for Combustion and Ventilation Product FeaturesDetermining FRESH-AIR Flow for Fireplace Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Electrical Hookup InstallationInstalling Hood Check GAS TypeConventional Fireplace Installation Installation ClearancesActual Framing Height 32 3/8 Front Width Depth BUILT-IN Fireplace InstallationMantel Clearances for Built-In Installation Installing GAS Piping to Fireplace LocationInstallation Items Needed Attaching Flexible Gas Lines Together Connecting Fireplace to GAS SupplyPressure Testing Fireplace Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Notches Screws for Mounting Screen Installing LogsThermostat-Controlled Models For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Blower Kit Model GA3750 Series Variable Control OperationBlower Operation Model VSGF28PTC Model VSGF28PVBlower Kit Model GA3650T Series Inspecting BurnersPilot Flame Pattern Front Burner Flame PatternCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement Wiring Diagram Technical ServiceReplacement Parts Service HintsEquipment Shutoff Valve GA5010 Cleaning KIT GCKCorner Mantel Corner Hearth BaseIllustrated Parts Breakdown KEY Part Number Description QTY Parts ListFireplace VSGF28PVA Parts List LOG Base Assembly LOG Base Assembly THERMOSTAT- Controlled Models Fireplace VSGF28PTC Parts List Warranty Information

VSGF28PTC, VSGF28PVA specifications

Vanguard Heating has made a significant mark in the heating solutions industry with its innovative models, the VSGF28PTC and VSGF28PVA. These units embody advanced technologies, reliable performance, and user-centric features that cater to both residential and commercial needs.

One of the standout characteristics of the VSGF28PTC and VSGF28PVA is their exceptional energy efficiency. Both models are designed to operate with a high Annual Fuel Utilization Efficiency (AFUE) rating, which ensures that more of the energy consumed is converted into usable heat. This not only helps in reducing energy bills but also contributes to lower carbon emissions, making these models an eco-friendly choice.

Both units feature a compact design that allows for easy installation in limited spaces, further enhancing their versatility. They are equipped with a two-stage gas valve that provides precise control over heating output, allowing users to enjoy consistent comfort throughout a variety of conditions. This technology helps maintain an even temperature while minimizing energy wastage.

Vanguard Heating has also integrated advanced safety features in these models. The built-in safety shutoff system will automatically turn off the unit in case of any detected malfunctions, giving users peace of mind. Additionally, these models incorporate flame rollout switches and pressure switches to ensure reliable operation and enhance overall safety.

Ease of use is another strong suit of the VSGF28PTC and VSGF28PVA. Their intuitive digital thermostats enable straightforward programming, allowing users to set heating schedules that suit their daily routines. This user-friendly interface is complemented by an easy-access filter that simplifies routine maintenance, ensuring optimal performance and extending the lifespan of the units.

Moreover, both models are designed for quiet operation, with sound-absorbing features that minimize noise, ensuring a comfortable indoor environment. For those in colder climates, the robust construction of these systems guarantees effective operation even in extreme temperatures.

In summary, Vanguard Heating's VSGF28PTC and VSGF28PVA present a winning combination of energy efficiency, advanced safety, user-friendly features, and quiet operation. These heating solutions promise reliability and peace of mind for anyone looking to enhance their indoor comfort while being mindful of energy consumption and environmental impact.