Vanguard Heating VDVF36PN, VDVF36STP Horizontal Termination Configurations, Horizontal Venting

Page 10

® VDVF36P and VDVF36ST Series

DIRECT-VENT GAS FIREPLACE HEATER

VENTING INSTALLATION

Continued

Horizontal Termination

Configurations

Figures 21 through 23 show different con- figurations for venting with horizontal ter- mination. Each figure includes a chart with vertical minimum/maximum and horizon- tal maximum dimensions which must be met. All connections must be sealed with high temperature silicone sealant as speci- fied in the second warning statement on

Horizontal Venting

Vertical (V)

Horizontal (H)

49.5" min.

15" max.

(45° elbow, 1' vertical pipe, 90° elbow)

61.5" min.

34" max.

73.5" min.

58" max.

85.5" min.

10' max.

102.5" min.

20' max.

UP

45° Starter

Elbow

Required

Note: The 30° Starter Elbow Must Be Discarded and Replaced with a 45° Starter Elbow.

page 7. All horizontal terminations require 1/4" rise per 12" of horizontal run.

Figure 21 - Horizontal Termination Configuration for Rigid Venting Using One 90° Elbow

Horizontal Venting

See information in Figure 21 for Vertical(V) and Horizontal(H) maxi- mums and minimums. The same amounts apply for flexible venting.

UP

FGFVK Vent Kit Shown

Figure 22 - Horizontal Termination Using Flexible Venting

10

105706

Image 10
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASGlossary Terms Supply Inlets Back SurroundSelecting Location IntroductionBefore YOU Begin Mantel Clearances PRE-INSTALLATION PreparationClearances FramingGeneral Venting Location of Vent TerminationGeneral Venting Installation Planning Venting InstallationInstallation Precautions Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Venting InstallationParts Lists for Venting High AltitudeElectrical Hookup for Blower Accessory Wall Switch InstallationInstalling Receiver GAS Line HOOK-UP GAS Rating Type of GAS Natural PROPANE/LPGAS Supply Testing Installing LOG SETDecorative Facing Pilot Assembly AdjustmentBurner Flame Adjustment Burner RemovalOperating Guidelines and Maintenance Instructions Lighting Instructions For Your Safety Read Before LightingOperating Fireplace To Turn OFF GAS To ApplianceGhrc Operation Ghrct OperationReplacement Parts Service HintsTechnical Service Wiring DiagramTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Pilot Assembly AccessoriesWall Switch KIT Blower KIT DavdbkOrifice Refractory PiecesGAS Control Valve Warranty Information

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.