Vanguard Heating VDVF36STN, VDVF36STP, VDVF36PN Refractory Pieces, Orifice, GAS Control Valve

Page 29

OWNER’S MANUAL

REPLACEMENT PARTS

Continued

Front (Bottom)

Left/Right (Bottom)

Rear (Used for Peninsula and See Thru)

REFRACTORY PIECES

Front (Bottom)

105886-01 (25854)

Left/Right (Bottom)

105887-01 (25856)

Rear - 105888-01 (25855)

PIEZO IGNITOR - 105884-01 (14261)

ORIFICE

Natural - 105890-01 (27224) Propane/LP - 105890-02 (25238)

SCREEN ASSEMBLY 105898-01 (25903)

GAS CONTROL VALVE

Natural - 105882-01 (25699) Propane/LP - 105882-02 (25700)

If in need of replacing, have a qualified technician replace it.

GRATE - 105889-01 (11184)

BURNER ASSEMBLY 105885-01 (27243)

LOUVER KIT

Black - 105904-01 (01627)

DOOR ASSEMBLY (Ceramic) 105897-01 (25706)

END GLASS ASSEMBLY (Peninsula Only)

105899-01 (25709) (Ceramic)

END LOUVER KIT (Peninsula Only)

Standard - 105900-01 (01645 )

105706

29

Image 29
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationSupply Inlets Back Surround Glossary TermsBefore YOU Begin IntroductionSelecting Location Clearances PRE-INSTALLATION PreparationMantel Clearances FramingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting InstallationVenting High AltitudeInstalling Receiver Wall Switch InstallationElectrical Hookup for Blower Accessory GAS Rating Type of GAS Natural PROPANE/LP GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingBurner Flame Adjustment Pilot Assembly AdjustmentDecorative Facing Burner RemovalOperating Guidelines and Maintenance Instructions Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceGhrct Operation Ghrc OperationTechnical Service Service HintsReplacement Parts Wiring DiagramObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Wall Switch KIT AccessoriesPilot Assembly Blower KIT DavdbkGAS Control Valve Refractory PiecesOrifice Warranty Information

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.