When lit for the first time, the appliance may emit a slight odor for about 16 - 24 hours. This is normal and is due to the “curing” of the logs and the “burn-in” of internal paints and lubricants used in the manufacturing process. Keep compartments, logs, burners, and area surrounding the logs clean by vacu- uming or brushing at least twice a year. Temporary removal of the log set may ease the cleaning of the burner and pilot assem- bly. In cleaning, take care not to alter the pilot or burner location. Be sure appliance is cool before each maintenance session.

CAUTION: The appliance and logs can get very hot - Handle only when cool.

WARNING: Turn off gas and wall switch before servicing ap- pliance. Any safety screen or guard removed for servicing the appliance must be replaced prior to operating the appliance.

Any household glass cleaner may be used to clean the glass panel. Do not use abrasive cleaners as this may damage the glass. Clean

glass only when cool.

WARNING: Do not operate appliance with panel(s) and glass removed, cracked, or broken. Re- placement of the panel(s) should be done by a licensed, qualified service person.

WARNING: Make certain wires and gas lines are not touching the underside of the firebox.

CAUTION: If the glass breaks, be cautious of fragments on the floor. Keep children away from the area. Do not operate the unit. Use proper safety gloves to re- move the broken glass door. Dis- card safely. A glass door kit can be ordered through your local distributor. Do not substitute other material for the glass.

WARNING: Children and adults should be alerted to the hazards of high surface tempera- tures, and to stay away from the appliance to avoid burns or cloth- ing ignition. Young children should be carefully supervised when they are in the same room as the appliance.

WARNING: Have a qualified agency periodically inspect the vent system at the start of each heating season, for any obstruc- tion which may hinder its normal operation. Never obstruct the flow of combustion and ventila- tion air. Keep the front of the appliance clear of all obstacles and materials.

WARNING: Do not abuse, strike, or slam the glass doors.

CAUTION: Label all wires prior to disconnection when ser- vicing controls. Wiring errors can cause improper and danger- ous operation.

For further operating guidelines, contact your authorized dealer.

20

105706

Image 20
Contents Check Local Codes Prior to Installation What to do if YOU Smell GASGlossary Terms Supply Inlets Back SurroundBefore YOU Begin IntroductionSelecting Location PRE-INSTALLATION Preparation ClearancesMantel Clearances FramingGeneral Venting Location of Vent TerminationGeneral Venting Venting Installation Installation PrecautionsInstallation Planning Installing Vent System in a ChaseInstallation for Horizontal Termination Snorkel TerminationVent Pipe Connections Horizontal Termination Configurations Horizontal VentingVenting with Two 90 Elbows Cathedral Ceiling Installation Installation for Vertical TerminationFlat Ceiling Installation Vertical Termination Configurations Venting with One 90 ElbowVertical Venting Installation Parts Lists for VentingVenting High AltitudeInstalling Receiver Wall Switch InstallationElectrical Hookup for Blower Accessory GAS Line HOOK-UP GAS Rating Type of GAS Natural PROPANE/LPGAS Supply Testing Installing LOG SETPilot Assembly Adjustment Burner Flame AdjustmentDecorative Facing Burner RemovalOperating Guidelines and Maintenance Instructions For Your Safety Read Before Lighting Operating FireplaceLighting Instructions To Turn OFF GAS To ApplianceGhrc Operation Ghrct OperationService Hints Technical ServiceReplacement Parts Wiring DiagramTroubleshooting Observed Problem Possible Cause RemedyObserved Problem Possible Cause Company Gas leak. See Warning statement Accessories Wall Switch KITPilot Assembly Blower KIT DavdbkGAS Control Valve Refractory PiecesOrifice Warranty Information

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.