Vanguard Heating VDVF36PP, VDVF36STP, VDVF36STN, VDVF36PN Gas leak. See Warning statement

Page 27

OWNER’S MANUAL

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating fireplace where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Fireplace produces unwanted odors

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks

 

 

above

 

 

 

 

 

 

 

Fireplace shuts off in use

1.

High or gusting winds

1.

Fireplace has been tested for up to

 

 

 

 

40mph winds. However, extreme con-

 

 

 

 

ditions may occur

 

2.

Low line pressure

2.

Contact local propane/LP or natural gas

 

 

 

 

company

 

3.

Pilot is partially clogged

3.

Clean pilot

 

4.

Inner vent pipe leaking exhaust gasses

4.

Locate and correct all leaks

 

 

into system

 

 

 

5.

Horizontal vent improperly pitched

5.

Horizontal vent termination should slope

 

 

 

 

down only enough to prevent any water

 

 

 

 

from entering the unit. The maximum

 

 

 

 

downward slope of the vent termination

 

 

 

 

is 1/4" for any horizontal run

 

6.

Glass too loose and air tight gasket leaks

6.

Tighten glass

 

 

in corners after usage

 

 

 

7.

Bad thermopile or thermocouple

7.

Replace faulty component

 

8.

Improper vent cap installation

8.

Check for proper installation and free-

 

 

 

 

dom from debris or blockage

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks

position

 

above

 

 

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks

 

 

above

 

 

 

 

 

 

 

Dark residue on logs or inside of fireplace

1.

Improper log placement

1.

Properly locate logs

 

2.

Air holes at burner inlet blocked

2.

Clean out air holes at burner inlets. Pe-

 

 

 

 

riodically repeat as needed

 

3.

Burner flame holes blocked

3.

Remove blockage or replace burner

www.desatech.com

105706

27

Image 27
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationSupply Inlets Back Surround Glossary TermsIntroduction Selecting LocationBefore YOU Begin Framing PRE-INSTALLATION PreparationClearances Mantel ClearancesLocation of Vent Termination General VentingGeneral Venting Installing Vent System in a Chase Venting InstallationInstallation Precautions Installation PlanningSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Installation for Vertical Termination Flat Ceiling InstallationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting High Altitude InstallationParts Lists for Venting VentingWall Switch Installation Electrical Hookup for Blower AccessoryInstalling Receiver GAS Rating Type of GAS Natural PROPANE/LP GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingBurner Removal Pilot Assembly AdjustmentBurner Flame Adjustment Decorative FacingOperating Guidelines and Maintenance Instructions To Turn OFF GAS To Appliance For Your Safety Read Before LightingOperating Fireplace Lighting InstructionsGhrct Operation Ghrc OperationWiring Diagram Service HintsTechnical Service Replacement PartsObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Blower KIT Davdbk AccessoriesWall Switch KIT Pilot AssemblyRefractory Pieces OrificeGAS Control Valve Warranty Information

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.