When ignitor button is pressed, there is no spark at pilot

1.Ignitor electrode not connected to igni- tor cable

2.Ignitor cable pinched or wet

3.Piezo ignitor nut is loose

4.Broken ignitor cable

5.Bad piezo ignitor

6.Ignitor electrode broken

7.Ignitor electrode positioned wrong

1.Reconnect ignitor cable

2.Free ignitor cable if pinched by any metal or tubing. Keep ignitor cable dry

3.Tighten nut holding piezo ignitor. Nut is located behind the mounting bracket

4.Replace ignitor cable

5.Replace piezo ignitor

6.Replace pilot assembly

7.Replace pilot assembly

When ignitor button is pressed, there is spark at pilot but no ignition

1.Gas supply turned off or manual shutoff valve closed

2.Control knob not in PILOT position

3.Control knob not pressed in while in PILOT position

4.Air in gas lines when installed

5.Depleted gas supply (propane/LP models only)

6.Pilot is clogged

7.Gas regulator setting is not correct

1.Turn on gas supply or open manual shutoff valve

2.Turn control knob to PILOT position

3.Press in control knob while in PILOT position

4.Continue holding down control knob. Repeat igniting operation until air is removed

5.Contact local propane/LP gas company

6.Clean pilot or replace pilot assembly

7.Replace gas control

Pilot lights but flame goes out when control knob is released

1.Control knob not fully pressed in

2.Control knob not pressed in long enough

3.Manual shutoff valve not fully open

4.Pilot flame not touching thermocouple, which allows thermocouple to cool, causing pilot flame to go out. This prob- lem could be caused by one or both of the following:

A)Low gas pressure

B)Dirty or partially clogged pilot

5.Thermocouple connection loose at con- trol valve

6.Thermocouple damaged

7.Control valve damaged

1.Press in control knob fully

2.After pilot lights, keep control knob pressed in 30 seconds

3.Fully open manual shut-off valve

4.A) Contact local gas company

B) Clean pilot or replace pilot assembly

5.Hand tighten until snug, then tighten 1/4 turn more

6.Replace thermocouple

7.Replace control valve

www.desatech.com

Continued

105706

25

Image 25
Contents What to do if YOU Smell GAS Check Local Codes Prior to InstallationSupply Inlets Back Surround Glossary TermsSelecting Location IntroductionBefore YOU Begin Clearances PRE-INSTALLATION PreparationMantel Clearances FramingLocation of Vent Termination General VentingGeneral Venting Installation Precautions Venting InstallationInstallation Planning Installing Vent System in a ChaseSnorkel Termination Installation for Horizontal TerminationVent Pipe Connections Horizontal Venting Horizontal Termination ConfigurationsVenting with Two 90 Elbows Flat Ceiling Installation Installation for Vertical TerminationCathedral Ceiling Installation Venting with One 90 Elbow Vertical Termination ConfigurationsVertical Venting Parts Lists for Venting InstallationVenting High AltitudeElectrical Hookup for Blower Accessory Wall Switch InstallationInstalling Receiver GAS Rating Type of GAS Natural PROPANE/LP GAS Line HOOK-UPInstalling LOG SET GAS Supply TestingBurner Flame Adjustment Pilot Assembly AdjustmentDecorative Facing Burner RemovalOperating Guidelines and Maintenance Instructions Operating Fireplace For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceGhrct Operation Ghrc OperationTechnical Service Service HintsReplacement Parts Wiring DiagramObserved Problem Possible Cause Remedy TroubleshootingObserved Problem Possible Cause Company Gas leak. See Warning statement Wall Switch KIT AccessoriesPilot Assembly Blower KIT DavdbkOrifice Refractory PiecesGAS Control Valve Warranty Information

VDVF36PN, VDVF36STP, VDVF36STN, VDVF36PP specifications

Vanguard Heating has established itself as a noteworthy player in the heating solutions market, and its latest offerings, the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN models, exemplify their commitment to innovative technology and user-centric design. These models are engineered to provide efficient heating solutions while enhancing the aesthetic appeal of any living space.

A standout feature of the Vanguard VDVF36 series is its sleek, modern design. These units seamlessly integrate into various architectural styles, making them an attractive option for both contemporary and traditional interiors. The VDVF36STN, for instance, showcases a stunning see-through option, allowing homeowners to enjoy the ambiance of flames from multiple angles.

These heating appliances utilize advanced gas burner technology, ensuring high thermal efficiency while maintaining a clean-burning flame. This results in reduced carbon emissions, making the VDVF36 series an environmentally responsible choice without compromising performance. The burners are designed to provide even heat distribution, minimizing cold spots and creating a comfortable atmosphere in the desired space.

One of the prominent technologies included in the Vanguard VDVF36 models is the remote control capability. Users can effortlessly manage temperature settings and flame height from the comfort of their seats, enhancing convenience and user experience. Additionally, the units come equipped with multiple flame settings, allowing users to customize the ambiance to match their mood or occasion.

Safety is a top priority in the design of the VDVF36 series. Each model features a built-in safety shutoff system, which automatically turns the unit off in the event of a malfunction, providing peace of mind for homeowners. Additionally, the glass front design incorporates advanced tempered glass technology, ensuring safety and durability while providing an unobstructed view of the flames.

The VDVF36 series also boasts easy installation and maintenance features. Designed for straightforward retrofitting, these units can be integrated into existing chimney systems or used with direct venting options, giving flexibility to home installations. Maintenance is simplified thanks to the accessible components, making routine checks hassle-free.

In summary, the Vanguard Heating VDVF36 models, including the VDVF36STN, VDVF36PP, VDVF36STP, and VDVF36PN, combine advanced technology with aesthetic appeal and safety features, offering users an efficient and stylish heating solution for their homes. Whether enhancing the comfort of a living room or adding charm to a gathering space, these models stand out as exceptional choices in modern heating technology.