Vanguard Heating VP1600D, VP2600D Installing To Wall, Continued, Thermostat Sensing Bulb

Page 10
INSTALLING TO WALL

10

INSTALLING TO WALL

Continued

For convenience and efficiency, install heater

where there is easy access for operation, inspection, and service

in coldest part of room

An optional fan kit is available from your dealer. See Accessories, page 31 If planning to use fan, locate heater near an electrical outlet.

CEILING

 

36"

8"

Minimum

 

Minimum

 

From

 

Sides Of

 

Heater

 

Left

Right

Side

Side

 

3" Minimum To Top Surface

FLOOR

Of Carpeting, Tile Or Other

Combustible Material

Figure 4 - Mounting Clearances As Viewed From Front of Heater

THERMOSTAT SENSING BULB

(Models VP1600ITA and VP2200ITA Only)

The thermostat sensing bulb has been placed inside the heater for protection during shipping.

Locating Thermostat Sensing Bulb

1.Remove front panel of heater (see Figure 7, page 11).

2.Locate thermostat sensing bulb just under burner assembly.

IMPORTANT: Attach thermostat sensing bulb to back of heater for proper operation.

Attaching Thermostat Sensing Bulb

1.Remove thermostat sensing bulb from holders inside heater. Route through slot opening in bottom of heater.

2.Place clamp on thermostat sensing bulb as shown in Figure 5. Clamp is provided in hardware package.

3.Snap clamp into upper mounting hole as shown in Figure 5. Mounting hole is located on lower left edge on back of heater. Make sure the thermostat sensing bulb is pointing up.

Thermostat

Sensing Bulb

THERMOSTAT SENSING BULB Clamp

Figure 5 - Attaching Thermostat Sensing Bulb

101823

Image 10
Contents OWNER’S OPERATION AND INSTALLATION MANUAL INFRARED VENT-FREEPROPANE/LP GAS HEATERINFORMATION CONTENTSSAFETY WARNINGSWARNINGS Continued SAFETY INFORMATIONContinued IDENTIFICATION FEATURESPRODUCT LOCAL CODESVENTILATION FRESH AIRCOMBUSTION Section 5.3, Air for Combustion and VentilationContinued FRESH AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION VENTILATION AIR FRESH AIR FOR COMBUSTION AND VENTILATIONContinued Ventilation Air From Inside BuildingVentilated Outlet Attic Air FRESH AIR FOR COMBUSTION AND VENTILATIONContinued OutletTO WALL INSTALLINGContinued Continued INSTALLING TO WALLTHERMOSTAT SENSING BULB TO WALL INSTALLINGINSTALLING HEATER TO WALL ContinuedMarking Screw Locations INSTALLING TO WALLContinued Attaching Mounting Bracket To WallContinued INSTALLING TO WALLInstalling Bottom Mounting Screws Placing Heater On Mounting BracketTO GAS CONNECTINGSUPPLY TO GAS CHECKINGCONNECTIONS SUPPLYTO GAS CONNECTINGPRESSURE TESTING HEATER GAS CONNECTIONS SUPPLYOPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTINGModels VP1600ITA and VP2200ITA Models VP1600ITA and VP2200ITA OPERATING HEATERLIGHTING INSTRUCTIONS ContinuedModels VP1600ITA and VP2200ITA HEATEROPERATING TO SELECT HEATING LEVELTHERMOSTAT OPERATION MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE OPERATING HEATERModels VP1600D OPERATINGand VP2600D FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER Models VP1600D and VP2600DContinued Models VP1600D and VP2600D OPERATING HEATERTO SELECT HEATING LEVEL ContinuedOPERATING HEATER INSPECTING BURNERMANUAL LIGHTING PROCEDURE TO TURN OFF GAS TO APPLIANCEContinued INSPECTING BURNERBURNER FLAME PATTERN TROUBLE CLEANINGMAINTENANCE SHOOTINGTROUBLE Cleaning and MainteCleaning and Mainte SHOOTINGsee Cleaning and TROUBLE- SHOOTINGsee Cleaning and see Cleaning andTROUBLE SERVICETECHNICAL SHOOTINGSERVICE PUBLICATIONS SERVICE HINTS SPECIFICATIONSPARTS REPLACEMENTACCESSORIES Parts Under WarrantyModel VP1600ITA ILLUSTRATEDBREAKDOWN PARTSPART PARTS LISTModel VP1600ITA NUMBERPARTS Model VP2200ITAILLUSTRATED BREAKDOWNModel VP2200ITA PARTS LIST098304-01 PARTS Model VP1600DILLUSTRATED BREAKDOWNModel VP1600D PARTS LIST098304-01 PARTS Model VP2600DILLUSTRATED BREAKDOWNModel VP2600D PARTS LIST098304-01 LIMITED WARRANTY WARRANTY INFORMATIONVANGUARD VENT-FREEPROPANE/LP GAS HEATERS