Vanguard Heating VP2200ITA Checking, Connections, To Gas, Supply, Continued, and/or fittings

Page 15
and/or fittings.

CONNECTING IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping

and/or fittings.

 

TO GAS

 

 

SUPPLY

 

 

Continued

 

 

Pressure Regulator

 

Regulator Bracket

 

Heater

1/2" NPT

Pipe Nipple

Cabinet

Ground Joint

 

 

 

Tee Joint

Union

 

 

Test

Reducer

Manual Shutoff Valve *

Gauge

Bushing to

 

Connection *

1/8" NPT

From

 

 

1/8" NPT

 

External Regulator

 

Plug Tap

(11" W.C. to 14" W.C. Pressure)

 

 

 

Tee Joint

 

Sediment

Pipe

3" Minimum

Trap

 

Nipple

 

 

Cap

 

 

 

Figure 14 - Gas Connection

*An AGA design certified manual shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional AGA design certified manual shutoff valve from your dealer. See Accessories, page 31.

CHECKING

WARNING

GAS

Test all gas piping and connections for leaks after installing or

CONNECTIONS

servicing. Correct all leaks at once.

 

 

 

 

 

WARNING

 

 

 

Never use an open flame to check for a leak. Apply a mixture of

 

liquid soap and water to all joints. Bubbles forming show a leak.

 

Correct all leaks at once.

 

 

TO GAS CAUTION

Make sure external regulator has been installed between propane/

LP supply and heater. See guidelines under Connecting to Gas

Supply, page 14.

PRESSURE TESTING GAS SUPPLY PIPING SYSTEM

Test Pressures In Excess Of 1/2 PSIG

1.Disconnect heater and its individual manual shutoff valve from gas supply piping system. Pressures in excess of 1/2 PSIG will damage heater regulator.

2.Cap off open end of gas pipe where manual shutoff valve was connected.

Continued 15

101823

Image 15
Contents INFRARED VENT-FREEPROPANE/LP GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUALWARNINGS CONTENTSSAFETY INFORMATIONSAFETY INFORMATION WARNINGS ContinuedContinued LOCAL CODES FEATURESPRODUCT IDENTIFICATIONSection 5.3, Air for Combustion and Ventilation FRESH AIRCOMBUSTION VENTILATIONFRESH AIR FOR COMBUSTION AND VENTILATION ContinuedDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Ventilation Air From Inside Building FRESH AIR FOR COMBUSTION AND VENTILATIONContinued VENTILATION AIROutlet FRESH AIR FOR COMBUSTION AND VENTILATIONContinued Ventilated Outlet Attic AirINSTALLING TO WALLContinued INSTALLING TO WALL ContinuedTHERMOSTAT SENSING BULB Continued INSTALLINGINSTALLING HEATER TO WALL TO WALLAttaching Mounting Bracket To Wall INSTALLING TO WALLContinued Marking Screw LocationsPlacing Heater On Mounting Bracket INSTALLING TO WALLInstalling Bottom Mounting Screws ContinuedCONNECTING TO GASSUPPLY SUPPLY CHECKINGCONNECTIONS TO GASSUPPLY CONNECTINGPRESSURE TESTING HEATER GAS CONNECTIONS TO GASFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING HEATERModels VP1600ITA and VP2200ITA Continued OPERATING HEATERLIGHTING INSTRUCTIONS Models VP1600ITA and VP2200ITATO SELECT HEATING LEVEL HEATEROPERATING Models VP1600ITA and VP2200ITAOPERATING HEATER MANUAL LIGHTING PROCEDURETO TURN OFF GAS TO APPLIANCE THERMOSTAT OPERATIONFOR YOUR SAFETY READ BEFORE LIGHTING OPERATINGand VP2600D Models VP1600DModels VP1600D and VP2600D OPERATING HEATERContinued Continued OPERATING HEATERTO SELECT HEATING LEVEL Models VP1600D and VP2600DTO TURN OFF GAS TO APPLIANCE INSPECTING BURNERMANUAL LIGHTING PROCEDURE OPERATING HEATERINSPECTING BURNER ContinuedBURNER FLAME PATTERN SHOOTING CLEANINGMAINTENANCE TROUBLESHOOTING Cleaning and MainteCleaning and Mainte TROUBLEsee Cleaning and TROUBLE- SHOOTINGsee Cleaning and see Cleaning andSHOOTING SERVICETECHNICAL TROUBLESPECIFICATIONS SERVICE PUBLICATIONS SERVICE HINTSParts Under Warranty REPLACEMENTACCESSORIES PARTSPARTS ILLUSTRATEDBREAKDOWN Model VP1600ITANUMBER PARTS LISTModel VP1600ITA PARTBREAKDOWN Model VP2200ITAILLUSTRATED PARTSPARTS LIST Model VP2200ITA098304-01 BREAKDOWN Model VP1600DILLUSTRATED PARTSPARTS LIST Model VP1600D098304-01 BREAKDOWN Model VP2600DILLUSTRATED PARTSPARTS LIST Model VP2600D098304-01 WARRANTY INFORMATION LIMITED WARRANTYVANGUARD VENT-FREEPROPANE/LP GAS HEATERS