Vanguard Heating VP2600D, VP1600ITA Installing To Wall, Continued, Marking Screw Locations

Page 12
Marking Screw Locations

12

INSTALLING TO WALL

Continued

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mount- ing bracket is level.

Attaching Mounting Bracket To Wall WARNING

Maintain minimum clearances shown in Figure 8. If you can, provide greater clearances from floor and joining wall.

2.Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

13"

16"

9 1/4"

16"

Min.

 

Min.

 

AdjoiningWall

 

AdjoiningWall

Only Insert Mounting

 

Only Insert Mounting

18 3/4"

 

18 3/4"

Screws Through Last

Min.

 

Screws Through Last

Min.

Hole On Each End

 

Hole On Each End

 

 

 

Floor

 

 

 

Floor

 

 

 

 

 

 

 

 

Models VP2600D and VP2200ITA

 

Models VP1600D and VP1600ITA

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hardware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry), drill at least 1" deep.

2.Fold wall anchor as shown in Figure 9.

Figure 9 - Folding Anchor

3. Insert wall anchor (wings first) into hole. Tap anchor flush to wall.

101823

Image 12
Contents OWNER’S OPERATION AND INSTALLATION MANUAL INFRARED VENT-FREEPROPANE/LP GAS HEATERCONTENTS SAFETYINFORMATION WARNINGSSAFETY INFORMATION WARNINGS ContinuedContinued FEATURES PRODUCTIDENTIFICATION LOCAL CODESFRESH AIR COMBUSTIONVENTILATION Section 5.3, Air for Combustion and VentilationFRESH AIR FOR COMBUSTION AND VENTILATION ContinuedDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION FRESH AIR FOR COMBUSTION AND VENTILATION ContinuedVENTILATION AIR Ventilation Air From Inside BuildingFRESH AIR FOR COMBUSTION AND VENTILATION ContinuedVentilated Outlet Attic Air OutletINSTALLING TO WALLContinued INSTALLING TO WALL ContinuedTHERMOSTAT SENSING BULB INSTALLING INSTALLING HEATER TO WALLTO WALL ContinuedINSTALLING TO WALL ContinuedMarking Screw Locations Attaching Mounting Bracket To WallINSTALLING TO WALL Installing Bottom Mounting ScrewsContinued Placing Heater On Mounting BracketCONNECTING TO GASSUPPLY CHECKING CONNECTIONSTO GAS SUPPLYCONNECTING PRESSURE TESTING HEATER GAS CONNECTIONSTO GAS SUPPLYFOR YOUR SAFETY READ BEFORE LIGHTING OPERATING HEATERModels VP1600ITA and VP2200ITA OPERATING HEATER LIGHTING INSTRUCTIONSModels VP1600ITA and VP2200ITA ContinuedHEATER OPERATINGModels VP1600ITA and VP2200ITA TO SELECT HEATING LEVELMANUAL LIGHTING PROCEDURE TO TURN OFF GAS TO APPLIANCETHERMOSTAT OPERATION OPERATING HEATEROPERATING and VP2600DModels VP1600D FOR YOUR SAFETY READ BEFORE LIGHTINGModels VP1600D and VP2600D OPERATING HEATERContinued OPERATING HEATER TO SELECT HEATING LEVELModels VP1600D and VP2600D ContinuedINSPECTING BURNER MANUAL LIGHTING PROCEDUREOPERATING HEATER TO TURN OFF GAS TO APPLIANCEINSPECTING BURNER ContinuedBURNER FLAME PATTERN CLEANING MAINTENANCETROUBLE SHOOTINGCleaning and Mainte Cleaning and MainteTROUBLE SHOOTINGTROUBLE- SHOOTING see Cleaning andsee Cleaning and see Cleaning andSERVICE TECHNICALTROUBLE SHOOTINGSERVICE PUBLICATIONS SERVICE HINTS SPECIFICATIONSREPLACEMENT ACCESSORIESPARTS Parts Under WarrantyILLUSTRATED BREAKDOWNModel VP1600ITA PARTSPARTS LIST Model VP1600ITAPART NUMBERModel VP2200ITA ILLUSTRATEDPARTS BREAKDOWNPARTS LIST Model VP2200ITA098304-01 Model VP1600D ILLUSTRATEDPARTS BREAKDOWNPARTS LIST Model VP1600D098304-01 Model VP2600D ILLUSTRATEDPARTS BREAKDOWNPARTS LIST Model VP2600D098304-01 WARRANTY INFORMATION LIMITED WARRANTYVANGUARD VENT-FREEPROPANE/LP GAS HEATERS