Vanguard Heating VMH3000TPSA Checking GAS Connections, Pressure Testing Gas Supply Piping System

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

CHECKING GAS

CONNECTIONS

WARNING: Test all gas pip- ing and connections for leaks after installing or servicing. Correct all leaks at once.

WARNING: Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once.

CAUTION: Make sure exter- nal regulator has been installed between propane/LP supply and heater. See guidelines under Con- necting to Gas Supply, page 12.

Pressure Testing Gas Supply Piping System

Test Pressures In Excess Of 1/2 PSIG (3.5 kPa)

1.Disconnect appliance with its appliance main gas valve (control valve) and equip- ment shutoff valve from gas supply pip- ing system. Pressures in excess of 1/2 psig will damage heater regulator.

2.Cap off open end of gas pipe where equipment shutoff valve was connected.

3.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

4.Check all joints of gas supply piping system. Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Reconnect fireplace and equipment shutoff valve to gas supply. Check re- connected fittings for leaks.

Test Pressures Equal To or Less Than 1/2 PSIG (3.5 kPa)

1.Close equipment shutoff valve (see Figure 20).

2.Pressurize supply piping system by ei- ther using compressed air or opening propane/LP supply tank valve.

3.Check all joints from propane/LP sup- ply tank to equipment shutoff valve (see Figure 21). Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak.

4.Correct all leaks at once.

Equipment

 

Shutoff

Open

Valve

Closed

Figure 20 - Equipment Shutoff Valve

Propane/LP

Supply Tank

Figure 21 - Checking Gas Joints

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 20).

2.Open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to thermostat gas valve (see Fig- ure 21). Apply mixture of liquid soap and water to gas joints. Bubbles form- ing show a leak.

5.Correct all leaks at once.

6.Light heater (see Operating Heater, pages 14 and 15). Check all other in- ternal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 14).

8.Replace front panel.

Thermostat Gas

Valve Location

Equipment

Shutoff

Valve

107102

13

For more information, visit www.desatech.com

Image 13
Contents What to do if YOU Smell GAS VENT-FREE PROPANE/LP GAS MINI-HEARTHHEATERLocal Codes Safety InformationProduct Features AssemblyProduct Identification UnpackingAssembling and Attaching Brass Trim Attaching Brass Front Trim to Front PanelLocate brass front trim in brass trim package Providing Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installation OptionsMounting Heater to Wall Mounting Heater on Optional Hearth Base Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Mounting Heater to Optional Hearth Base Mounting Heater to Optional MantelSecuring Hearth Base to Floor External Regulator with Vent Pointing Down Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceInspecting Burner Manual Lighting ProcedureThermostat Control Operation Pilot Flame PatternPilot assembly TroubleshootingSafety interlock system has been After ODS/pilot lights, keep controlPane/LP company Maintenance,Position Gas odor even when control knob is in OFFReplacement Parts Cleaning and MaintenanceVMH3000TPSA Illustrated Parts BreakdownKEY VMH3000TPSA Description QTY Parts ListTechnical Service SpecificationsService Hints When Gas Pressure Is Too LowAccessories Warranty Information